Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric SURT001 is a 3000 VA rack-mount isolation transformer designed to extend the capabilities of APC Smart-UPS RT systems operating on 230V infrastructure. If your deployment requires galvanic isolation between the utility feed and protected loads — a common requirement in medical facilities, broadcast environments, industrial control rooms, and security operations centers — the SURT001 slots directly into existing Smart-UPS RT installations without introducing additional power conversion stages. It occupies 3U of rack space, accepts a C20 input coupler from the upstream UPS, and delivers a C19 output to downstream distribution, keeping the entire power chain on standard IEC connectors throughout.
For integrators specifying power protection and UPS equipment, isolation transformers are often the overlooked piece: you can have clean, battery-backed power and still pass ground-loop noise or common-mode interference to sensitive electronics. The SURT001 addresses that gap for 230V APC Smart-UPS RT deployments specifically.
The SURT001 is engineered for the APC by Schneider Electric Smart-UPS RT product family operating on 230V circuits. The C20-to-C19 connection topology is the standard handoff in APC's RT-series power chain: UPS output (C19/C20) → isolation transformer input (C20) → transformer output (C19) → rack PDU or direct load. If you are specifying a complete power protection stack for a security operations center, broadcast edit suite, or industrial control environment, this transformer integrates cleanly into that chain without requiring any custom interface hardware.
For UPS accessories and power conditioning planning, verify that your upstream Smart-UPS RT model is rated at or above 3000 VA on the 230V rail before pairing with the SURT001 — undersizing the UPS relative to the transformer's rated capacity eliminates the protection buffer you are specifying this unit to provide. Also confirm the upstream circuit breaker and branch wiring support the 16A maximum input draw; most 230V commercial circuits run 16A or 20A breakers, but older installations may be 10A and would require an upgrade.
Consulting your power protection planning guide before finalizing rack layout is worthwhile — isolation transformer placement relative to the UPS, PDU, and grounding scheme directly affects the quality of isolation you achieve in practice.
Q: What UPS systems is the SURT001 designed to work with?
A: The SURT001 is designed for use with the APC Smart-UPS RT series operating on 230V AC infrastructure. It uses a C20 inlet to connect to the UPS output and a C19 outlet to feed downstream distribution.
Q: What is the load capacity of the SURT001?
A: The SURT001 is rated at 3000 VA. It accepts up to 16A input current on a 230V circuit, covering the full output capacity of a compatible Smart-UPS RT 3000 unit.
Q: How much rack space does the SURT001 require?
A: The SURT001 occupies 3U of standard 19-inch (432mm) rack space. Verify available rack units in your installation before ordering.
Q: What input frequency range does the SURT001 support?
A: The SURT001 accepts input at 50 Hz or 60 Hz, making it compatible with both European and international 230V power infrastructure.
Q: What are the operating temperature and humidity limits for the SURT001?
A: Operating temperature is 0 to 40°C. Operating relative humidity is 0 to 95% (non-condensing). Storage temperature range extends from -25°C to 65°C.
Q: How many output connections does the SURT001 provide?
A: The SURT001 provides a single C19 IEC output coupler. Downstream multi-outlet distribution is handled by connecting a rack PDU to that C19 output.

The SURT001 is one of those components that gets specified correctly the first time by engineers who have dealt with ground-loop noise in sensitive rack environments, and gets skipped by everyone else until something goes wrong. With a 3000 VA rating and a straightforward C20-in / C19-out topology, it inserts cleanly into a Smart-UPS RT 230V power chain — but the real value is galvanic isolation, not power conditioning alone.
Technical Highlights:
Deployment Considerations:
The SURT001 is the right call for security operations centers, broadcast control rooms, and medical-adjacent rack environments on 230V infrastructure where common-mode noise or ground loops are a known concern and the upstream UPS is already an APC Smart-UPS RT. It is not a general-purpose transformer and should not be specified outside that platform context.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price