Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SURT1000RMXLI 1000VA 2U Rack-Mount Double-Conversion Online UPS

Overview

The SURT1000RMXLI is a 1000VA / 700W double-conversion online UPS designed for 2U rack installations running on 230V infrastructure. Unlike standby or line-interactive UPS designs, double-conversion topology means connected loads run off clean, inverter-generated power at all times — the utility feed never touches your equipment directly. That matters in environments where incoming power quality is unreliable, where power conditioning is as important as runtime, and where a UPS power protection solution needs to deliver genuinely clean sine wave output rather than a switched approximation. For network video recorders, edge switches, and access control servers that depend on stable power continuity, the always-on conversion eliminates micro-outages and brownouts that would otherwise cause unexpected reboots or data corruption.

Key Features

  • Double-Conversion Online Topology: Connected loads run continuously off the inverter — there is zero transfer time on utility failure. For NVRs and servers where even a 10ms gap can trigger a reboot, this is the architecture that eliminates that risk entirely. Standby and line-interactive units cannot make this claim.
  • 1000VA / 700W Rated Capacity at 230V: At a 0.7 power factor, this unit supports real-world mixed loads of servers, switches, and IP cameras. Size your load to 80% of rated capacity (560W) for thermal headroom and battery longevity — this is not a marketing caveat, it is standard UPS practice.
  • Pure Sine Wave Output, <3% THD: Less than 3% total harmonic distortion and a 3:1 crest factor means the output is clean enough for active PFC power supplies — the kind found in modern rack servers and NVRs. Simulated or stepped sine wave units can destabilize active-PFC loads; this unit eliminates that compatibility risk.
  • 6 IEC 60320 C13 Outlets + 2 IEC Jumper Outputs: Eight protected output connections in a 2U footprint. The jumper outputs allow daisy-chaining to an external bypass maintenance switch without breaking the circuit — useful in 24/7 surveillance environments where scheduled maintenance windows do not exist.
  • Built-In Bypass: The integrated bypass allows servicing or replacement without cutting power to downstream equipment. In a live security operations environment, this is the difference between a scheduled swap and an unplanned outage.
  • 3-Hour Recharge to Full Capacity: With a 109W battery charger, the lead-acid battery returns to full charge within 3 hours after a discharge event. For sites with intermittent grid instability, this recharge cadence matters — a unit that takes 8+ hours to recover leaves you exposed on back-to-back events.
  • Full-Time Multi-Pole Noise Filtering, Zero IEEE Let-Through, 420J Surge: Noise suppression runs continuously — not just during events — and the IEEE surge let-through rating of zero means transients on the utility feed are blocked before they reach connected equipment. The 420J surge energy rating handles typical industrial electrical environment transients.
  • Output Frequency Stability ±3 Hz User-Adjustable: Output frequency is user-adjustable to match local grid nominal (50 or 60 Hz), with ±3 Hz tolerance. The unit auto-senses input frequency within ±5 Hz, making it compatible with generators that drift slightly under load — a real-world scenario in remote surveillance installations.
  • Operating Temperature 0–40°C, IP20 Rated: Designed for conditioned indoor rack environments. IP20 means no protection against liquids — this unit belongs in a locked equipment room or data closet, not an outdoor enclosure or uncontrolled environment.
  • 50 dBA Acoustic Level: Fan noise at 50 dBA is audible in a quiet room but standard for a double-conversion unit of this class. Plan placement accordingly — adjacent to open-plan workstations is not ideal; inside a closed rack room is the intended deployment.
  • Battery Life 3–5 Years, Lead-Acid Chemistry: Expected battery service interval is 3 to 5 years under normal conditions. Factor in a battery replacement budget at year 3 for any deployment where runtime continuity is load-bearing.
  • 1 Free Expansion Slot: One open slot accommodates an optional UPS network management card for SNMP monitoring, remote shutdown scripting, or integration with a building management system — relevant for enterprise deployments where UPS events need to trigger automated workflows.

Integration and Compatibility

The SURT1000RMXLI accepts input voltages from 160V to 280V on a C14 inlet, covering the full range of 220V / 230V / 240V utility standards common across EMEA and Asia-Pacific regions. Output is fixed at 230V (with 220V and 240V variants available on connected loads via the IEC jumpers). The unit carries C-Tick, CE, GOST, VDE, UK PSTI certifications, confirming compliance for deployment across the EU, UK, Russia, and Australia. It meets EN/IEC 62040-1:2019 and EN/IEC 62040-2:2018 safety and EMC standards — relevant for integrators who need to document regulatory compliance in commissioning packages. The 2U rack form factor integrates into standard 19-inch server rack enclosures without adapters.

Frequently Asked Questions

Q: What is the difference between the SURT1000RMXLI's double-conversion topology and a line-interactive UPS?

A: In double-conversion online mode, connected equipment always runs off inverter-generated power — the utility feed charges the battery, which feeds the inverter, which powers the load. There is zero transfer time on utility failure because the inverter never switches off. A line-interactive UPS passes utility power directly to the load under normal conditions and only switches to inverter on failure, introducing a transfer gap of typically 4–20ms. For NVRs, servers, and access control systems where even a brief gap can cause a reboot or data write error, double-conversion is the correct architecture.

Q: What input voltage range does the SURT1000RMXLI accept?

A: The unit accepts input voltages from 160V to 280V at 50/60 Hz (±5 Hz auto-sensing), covering standard 220V, 230V, and 240V utility supplies. The input connection is an IEC 60320 C14 inlet.

Q: How many outlets does the SURT1000RMXLI provide and what types are they?

A: The unit provides 6 IEC 60320 C13 outlets plus 2 IEC jumper outputs, for a total of 8 protected output connections. The jumper outputs support maintenance bypass switching without interrupting downstream loads.

Q: What certifications does the SURT1000RMXLI carry?

A: The SURT1000RMXLI carries C-Tick (Australia), CE (European Union), GOST (Russia), VDE (Germany), and UK PSTI certifications. It also conforms to EN/IEC 62040-1:2019/A11:2021 and EN/IEC 62040-2:2018 safety and EMC standards.

Q: How long does the battery take to recharge after a full discharge?

A: The integrated 109W battery charger returns the lead-acid battery to full capacity in approximately 3 hours. Expected battery service life is 3 to 5 years under normal operating conditions.

Q: Can the SURT1000RMXLI be monitored remotely via SNMP?

A: Remote SNMP monitoring requires an optional network management card installed in the single available expansion slot. The base unit does not include a network management card — this is an add-on accessory purchased separately.

Marty Allison
Marty Allison

The SURT1000RMXLI earns its place in surveillance and security infrastructure racks specifically because of the double-conversion online topology — not just the 1000VA capacity. Most integrators underestimate how often brownouts and micro-interruptions hit NVRs in commercial buildings with shared electrical infrastructure: HVAC cycling, elevator motor surges, and lighting ballast noise are all real grid-contamination sources. Since the SURT1000RMXLI's inverter is always in the power path, those events never reach connected equipment. The load sees clean 230V sine wave output at less than 3% THD, continuously.

Technical Highlights:

  • Zero Transfer Time: Because the inverter never idles, there is no switching gap on utility failure — critical for NVRs and servers that will reboot or lose a write cycle on even a 10ms outage. Standby units cannot match this.
  • 109W Battery Charger / 3-Hour Recovery: The 109W charger is sized to recover the lead-acid battery in 3 hours — faster than many competing units at this capacity class. On sites with repeated short outages (common near industrial equipment), fast recovery matters as much as runtime.
  • Built-In Bypass + 1 Expansion Slot: The integrated bypass lets you service or hot-swap the unit without dropping connected loads. Add an optional network management card in the free expansion slot and you get SNMP-based UPS event alerting into your VMS or DCIM platform — no separate monitoring appliance needed.

Deployment Considerations:

  • Load planning is critical: at 700W rated, plan for no more than 560W of actual connected load (80% rule) to preserve thermal margin and battery cycle life. Overloading to 90%+ accelerates battery aging toward the low end of the 3-year service interval.
  • The 50 dBA acoustic level is non-trivial — this unit should not be deployed in open office areas adjacent to workstations. It belongs in a dedicated equipment room or server closet where fan noise is not a daily irritant or compliance issue.

The SURT1000RMXLI is the right call for a 2U rack position in a regional security operations center or mid-size commercial NVR closet where power quality — not just runtime — is the primary concern, and where the 230V IEC outlet configuration matches the installed equipment base.

Specifications
Color: Black
Height: 8.5 cm
Width: 43.2 cm
Depth: 48.3 cm
Net Weight: 23 kg
Mounting Mode: Rack-mounted
UPS Type: Double conversion online
Network Frequency: 50/60 Hz +/- 5 Hz auto-sensing
Input Voltage Limits: 160...280 V
Maximum Configurable Power VA: 1000 VA
Maximum Configurable Power W: 700 W
Output Frequency: 50/60 Hz +/- 3 Hz user adjustable
Wave Type: Sine wave
Harmonic Distortion: Less than 3 %
Crest Factor: 3 : 1
Bypass Type: Built-in bypass
Product Certifications: C-Tick CE GOST VDE UK PSTI
Standards: EN/IEC 62040-1:2019/A11:2021 EN/IEC 62040-2:2006/AC:2006 EN/IEC 62040-2:2018
Operating Temperature: 0…40 °C
Operating Relative Humidity: 0…95 % non-condensing
Operating Altitude: 0...10000 ft
Storage Temperature: -20…50 °C
Storage Relative Humidity: 0…95 % non-condensing
Storage Altitude: 0.0000000000…15240.0000000000 m
Acoustic Level: 50 dBA
Heat Dissipation: 324 Btu/h
IP Degree of Protection: IP20
Free Slots: 1
Surge Energy Rate: 420 J
Noise Suppression: Full time multi-pole noise filtering
IEEE Surge Let-through: zero
Clamping Response Time: meets UL 1449
Main Input Voltage: 230 V
Product Component Type: Uninterruptible power supply (UPS)
Other Input Voltage: 220 V 240 V
Main Output Voltage: 230 V
Other Output Voltage: 220 V 240 V
Rated Power W: 700 W
Rated Power VA: 1000 VA
Input Connection Type: IEC 60320 C14
Output Connection Type: 6 IEC 60320 2 IEC Jumpers
Number of Rack Unit: 2U
Battery Type: Lead-acid battery
Battery Recharge Time: 3 h
Battery Charger Power: 109 W rated
Battery Life: 3…5 year(s)
freight: 186.60
Q&A
Reviews

APC Smart-UPS RT 1000VA RM 230V - SURT1000RMXLI

$2,595.00
$1,694.99

RELATED PRODUCTS

Save $9,134.01
APC by Schneider Electric Smart-ups RT 15KVA RM 230V
Add to Cart The item has been added

APC by Schneider Electric SURT15KRMXLI

APC by Schneider Electric 15KVA UPS - SURT15KRMXLI

15 kVA / 12,000 W double-conversion online UPS designed for rack-mounted critical infrastructure — server rooms, network closets, broadcast

    Usually Ships in 2-3 Weeks Free shipping over $499
    $26,965.00 $17,830.99 Save $9,134.01
    The item has been added Add to quote
    $26,965.00 $17,830.99 Save $9,134.01
    Save $9,134.01 Add to cart Add to quote
    Save $10,404.01
    APC Smart-ups RT 15KVA RM 208V - SURT15KRMXLT
    Add to Cart The item has been added

    APC by Schneider Electric SURT15KRMXLT

    APC Smart-ups RT 15KVA RM 208V - SURT15KRMXLT

    PC's Smart-UPS RT rated at 15KVA for 208V environments — a rack-mount power protection unit sized for network closets, server rooms, and edge data

      Usually Ships in 2-3 Weeks Free shipping over $499
      $30,575.00 $20,170.99 Save $10,404.01
      The item has been added Add to quote
      $30,575.00 $20,170.99 Save $10,404.01
      Save $10,404.01 Add to cart Add to quote
      Save $6,060.01
      APC Smart-ups SRT 10000VA RM 230V - SRT10KRMXLI
      Add to Cart The item has been added

      APC by Schneider Electric SRT10KRMXLI

      APC Smart-ups SRT 10000VA RM 230V - SRT10KRMXLI

      10,000VA rack-mount uninterruptible power supply designed for 230V environments where continuous power availability is non-negotiable

        Usually Ships in 2-3 Weeks Free shipping over $499
        $17,685.00 $11,624.99 Save $6,060.01
        The item has been added Add to quote
        $17,685.00 $11,624.99 Save $6,060.01
        Save $6,060.01 Add to cart Add to quote

        System Design, Deployment & Technical Support

        Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

        Fixed scope • Fixed price

        System Design Assistance

        • Get help validating product compatibility
        • Coverage requirements
        • Storage planning and deployment architecture before you buy.
        Request Design Help

        Deployment & Configuration Support

        • Access fixed-scope support for rollout planning
        • User setup guidance
        • Migration and system standardization across single-site or multi-site deployments
        View Support Services

        Guides, Tools & Calculators

        • PoE requirements
        • Storage retention
        • Camera selection and deployment methodology
        Open Technical Resources