Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The SUA5000RMT5U is a 5000VA / 4000W line-interactive uninterruptible power supply designed for mid-to-large rack deployments running 208V infrastructure. At 5U tall, it fits standard 19-inch enclosures and converts to tower orientation when rack space is at a premium — a practical option for wiring closets, server rooms, and distributed IT equipment rooms that haven't committed to a full rack build-out. If you're powering a dense camera server, a network video recorder stack, or any 208V commercial load that can't tolerate a dropped input cycle, this unit is sized to bridge the gap between a power event and an orderly shutdown or generator handoff.
Line-interactive topology means the SUA5000RMT5U's automatic voltage regulation (AVR) corrects under-voltage and over-voltage conditions using the internal transformer — without switching to battery. That's important in commercial environments where brownouts and line sags are common; every unnecessary battery cycle shortens battery life and raises replacement costs.
The SUA5000RMT5U is compatible with APC's SmartSlot expansion bay, which accepts network management cards (NMC) for SNMP/Modbus integration into building management systems, NMS platforms, and data center infrastructure management (DCIM) tools. This makes it deployable in managed environments where per-device power monitoring and remote shutdown scripting are required.
For power and UPS solutions across mixed-voltage deployments, verify that every downstream device is rated for 208V input — the SUA5000RMT5U outputs 208V and is not a step-down transformer. Connecting 120V-only equipment without a suitable PDU or transformer will damage that equipment.
This unit fits naturally into rack builds alongside managed PoE network switches and network video recorders where continuous uptime during power events is a project requirement. For the broader APC by Schneider Electric catalog, including smaller desktop UPS units and 120V tower models, review the full line to match the right capacity to each circuit. See also our UPS sizing and selection guide for runtime calculation methodology and load-planning worksheets.
Q: What is the runtime of the SUA5000RMT5U at full load?
A: At full 4000W / 5000VA load, the SUA5000RMT5U provides approximately 9.4 minutes of backup runtime. At half load (approximately 2000W), runtime extends to 26.7 minutes. Actual runtime varies based on battery age, temperature, and connected load profile.
Q: Does the SUA5000RMT5U support hot-swap battery replacement?
A: Yes. The SUA5000RMT5U supports hot-swap battery replacement, meaning batteries can be changed while the unit remains online and powering connected equipment. This eliminates the need to schedule downtime for routine battery maintenance.
Q: What input voltage does the SUA5000RMT5U require?
A: The SUA5000RMT5U is designed for 208V input, which is standard on commercial electrical panels and data center PDUs. It is not compatible with standard 120V residential circuits without a step-up transformer.
Q: Does the SUA5000RMT5U have an Emergency Power Off (EPO) input?
A: Yes. The unit includes a hardwired EPO input that allows integration with facility fire suppression systems or manual emergency cutoff panels. EPO wiring requirements vary by local electrical code — consult your AHJ before installation.
Q: Can the SUA5000RMT5U be used in both rack and tower orientation?
A: Yes. The SUA5000RMT5U ships in a 5U rackmount form factor and also supports tower orientation, making it flexible for deployments where a full equipment rack is not available.
Q: How long does it take to recharge the SUA5000RMT5U batteries after a full discharge?
A: Battery recharge time after a full discharge is approximately 3 hours under normal operating conditions.

The SUA5000RMT5U is a unit I regularly recommend for mid-density server and surveillance rack builds on 208V commercial circuits. That 9.4-minute full-load runtime spec is the number most integrators get wrong during sizing — they design to the nameplate VA and forget to account for real watt draw under peak conditions. At 4kW real power, you have enough bridge time for a clean OS shutdown or generator transfer, but if you're stacking this unit under a dense NVR array with spinning surveillance drives, measure the actual watt load before commissioning.
Technical Highlights:
Deployment Considerations:
This unit fits well in 208V commercial rack builds supporting NVR stacks, edge compute nodes, or access control head-end equipment where planned runtime of 9–27 minutes covers either a clean shutdown or a standby generator's transfer window — the SUA5000RMT5U handles that scenario cleanly as long as the load is sized to its 4kW real-power ceiling.