APC by Schneider Electric
SKU: APDU11150SW
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU11150SM is APC's advanced switched metered-by-outlet rack PDU rated for 7,400 VA at 230V single-phase — built for data center rows, server racks, and high-density network closets where per-outlet visibility and remote switching aren't optional. This is the unit you specify when facilities need to remotely cycle a hung device at 2 a.m. without rolling a tech, or when power accounting by tenant, department, or application tier matters. Browse the full APC by Schneider Electric rack power distribution lineup to compare models across the switched, metered, and basic PDU families.
The APDU11150SM integrates with APC's EcoStruxure IT platform and APC Data Center Expert (DCE) for centralized power monitoring, alarm management, and capacity planning. SNMP v1/v2c/v3 and Modbus TCP support drop it into most existing DCIM and BMS environments without a gateway device. The NPS architecture means large deployments — think 20+ PDUs per row — can be consolidated behind a single management IP and monitored through a single network switch port, a real operational simplification at scale. For pairing with rack PDUs in high-availability configurations, APC's AOS firmware supports outlet group policies and load threshold alerting natively.
If you're deploying this in a UPS-backed configuration, verify your UPS output plug matches the IEC 309 32A input — APC's Smart-UPS and Symmetra lines include compatible 32A outputs in the relevant VA classes. For large-scale structured deployments, pair this PDU with a managed PoE switch to keep the NPS management traffic on a dedicated VLAN segment away from production traffic.
Review the data center power planning guide for outlet loading, derating, and circuit-to-PDU sizing considerations before finalizing rack layout.
Q: How many PDUs can share a single IP address using the NPS ports on the APDU11150SM?
A: Up to 32 PDUs can be linked via the two NPS (Network Port Sharing) ports, all managed under a single network IP address. This dramatically reduces switch port consumption and IP address overhead in large deployments.
Q: What is the metering accuracy of the APDU11150SM?
A: The APDU11150SM provides per-outlet metering at ±1% accuracy — sufficient for chargeback billing, capacity planning, and threshold-based alerting in multi-tenant or departmental environments.
Q: What input plug does the APDU11150SM use, and what circuit does it require?
A: The unit uses an IEC 309 32A input plug and requires a 230V single-phase circuit rated for 32A. Ensure your panel and circuit breaker are sized appropriately before installation — the PDU draws up to 32A at full load.
Q: Can I remotely reboot individual outlets on the APDU11150SM without affecting other outlets?
A: Yes. The switched architecture allows per-outlet on/off/reboot commands independently via the web UI, SNMP, or REST API. Only the target outlet is affected; all other outlets remain uninterrupted.
Q: What outlet types are available on the APDU11150SM?
A: The unit provides 20 output receptacles in a mixed configuration supporting C13, C15, C19, and C21 IEC outlet types, accommodating standard servers, higher-draw compute nodes, and hot-equipment applications without adapters.
Q: What is the maximum operating temperature for the APDU11150SM?
A: The APDU11150SM is rated for operation up to 60°C (140°F), making it suitable for high-density rack deployments where hot-aisle temperatures are elevated.

The APDU11150SM is the PDU I reach for when a client needs genuine outlet-level control and billing-grade metering in a 230V environment — specifically because that 1% metering accuracy holds up under audit in shared infrastructure scenarios where rough estimates won't satisfy facilities or finance. The 32A IEC 309 input is the right connector for this load class; don't try to adapt a 16A feed to this unit.
Technical Highlights:
Deployment Considerations:
This PDU is the right specification for colocation cage deployments, high-density security operations center racks, and enterprise server rooms where outlet-level accountability, remote power cycling, and the ability to scale management across 32 units per IP are non-negotiable operational requirements.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →