Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric APDU11350SM is a 0U three-phase switched metered outlet rack PDU designed for high-density data center and server room deployments where per-outlet control, branch-level metering, and intelligent remote management are non-negotiable. Rated at 17.3KW (34,600 VA) across a 400V/60A three-phase feed, it delivers the raw capacity to power fully loaded rack PDU environments — compute-dense rows, GPU clusters, or mixed-load cabinets — without requiring a separate power supply or additional management module.
This unit sits in the APC by Schneider Electric Netshelter Advanced PDU line, which targets enterprise-grade power distribution where basic metering falls short and operators need outlet-level switching to remotely cycle locked-up servers, stagger boot sequences, or enforce load policies without dispatching a technician.
The APDU11350SM integrates into environments running APC's EcoStruxure IT platform, enabling DCIM-layer monitoring alongside other APC and Schneider Electric infrastructure. The NMC3 card supports industry-standard protocols (SNMP, Modbus) that feed into third-party DCIM and power management platforms. With five Ethernet ports, this unit can participate in redundant management network topologies without external switches. The four outlet types (C13/C15/C19/C21) ensure broad compatibility with standard server PSUs, network switch power inputs, and specialty high-temperature equipment — reducing the need for adapter cords that complicate audits and introduce failure points. Consider pairing with a compatible APC UPS system upstream to provide the runtime buffer that a switched PDU cannot supply on its own.
Q: What input voltage and phase configuration does the APDU11350SM require?
A: The APDU11350SM requires a 400V three-phase input at up to 60A, with 50/60 Hz compatibility. This is a 3PH unit — it is not compatible with single-phase circuits.
Q: How many outlets does the APDU11350SM provide, and what connector types are included?
A: It provides 42 AC outlets in four types: C13, C15, C19, and C21. This covers standard IEC server connections, high-temperature C15 applications, and high-current C19/C21 loads.
Q: Does the APDU11350SM support per-outlet switching, or only branch-level control?
A: The APDU11350SM is a switched metered outlet PDU, meaning it supports per-outlet switching — individual outlets can be remotely powered on, off, or cycled independently through the NMC3 management interface.
Q: What management platform does the APDU11350SM use, and how many network ports does it have?
A: It uses APC's NMC3 (Network Management Card 3) platform with five RJ-45 Ethernet ports, supporting network segmentation and out-of-band management topologies.
Q: Does the APDU11350SM take up rack unit space?
A: No. The APDU11350SM is a 0U device — it mounts vertically in a rack's side channel and consumes zero rack units, preserving all available U-space for compute and networking equipment.
Q: Is the APDU11350SM RoHS compliant?
A: Yes. The APDU11350SM carries RoHS compliance certification, meeting EU hazardous substance restrictions for deployments with environmental compliance requirements.

The APDU11350SM is the unit I recommend when a customer needs outlet-level switching at genuine three-phase scale — 34,600 VA across a 400V/60A feed is not a spec you find on entry-tier PDUs, and the NMC3 with five Ethernet ports puts this in a different class than most competitors' single-port management cards. If you're running a high-density compute row and need both granular control and real network management flexibility, this is where the hardware earns its position.
Technical Highlights:
Deployment Considerations:
The APDU11350SM is best matched to European or multinational data center rows running high-density compute at 400V three-phase, where operators need per-outlet switching, live load metering, and a management network that can be properly segmented — colocation providers and enterprise data centers with strict change-management and remote-hands-reduction mandates are the primary fit.