Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric APDU11350SM Advanced Switched Metered Outlet Rack PDU

Overview

The APC by Schneider Electric APDU11350SM is a 0U three-phase switched metered outlet rack PDU designed for high-density data center and server room deployments where per-outlet control, branch-level metering, and intelligent remote management are non-negotiable. Rated at 17.3KW (34,600 VA) across a 400V/60A three-phase feed, it delivers the raw capacity to power fully loaded rack PDU environments — compute-dense rows, GPU clusters, or mixed-load cabinets — without requiring a separate power supply or additional management module.

This unit sits in the APC by Schneider Electric Netshelter Advanced PDU line, which targets enterprise-grade power distribution where basic metering falls short and operators need outlet-level switching to remotely cycle locked-up servers, stagger boot sequences, or enforce load policies without dispatching a technician.

Key Features

  • 17.3KW / 34,600 VA Three-Phase Capacity: A 400V three-phase input at 60A means this PDU can carry full-rack compute loads that would saturate multiple single-phase units. In practice, this is the right capacity tier for blade chassis, high-density hyperconverged nodes, or AI inference racks pulling 10–16KW sustained — you have headroom rather than running near the breaker trip point.
  • 42 AC Outlets — Four Receptacle Types (C13, C15, C19, C21): The mix of C13, C15, C19, and C21 connectors matters in mixed hardware environments. C15 handles high-temperature equipment (switches, some UPS-adjacent gear) where standard C13 cords are rated too low; C19/C21 cover high-current server PSUs and PDU-chained devices. Having all four types on a single unit eliminates the adapter proliferation that creates cable-management headaches and potential loose-connection faults in production racks.
  • Switched Outlet Control (Per-Outlet): Per-outlet switching lets you remotely power-cycle an unresponsive server, sequence startup order across a rack to protect upstream UPS capacity, or de-energize a specific outlet for maintenance — without touching adjacent live equipment. This is the feature that separates this unit from basic metered PDUs and justifies its position in data center power infrastructure requiring remote hands reduction.
  • NMC3 Management Platform with 5x RJ-45 Ethernet Ports: The NMC3 (Network Management Card 3) is APC's current-generation embedded controller. Five RJ-45 ports — not one — support network segmentation, dual-network or out-of-band management topologies, and higher-availability architectures. This matters in colocation or multi-tenant environments where management traffic must be isolated from production networks. NMC3 also supports HTTPS, SNMPv3, RADIUS, and modern cybersecurity baselines that NMC2 deployments couldn't satisfy.
  • Metered Outlet-Level Monitoring: Branch-level and per-outlet current metering gives operations teams live load data without relying on IPMI polling or out-of-band server agents. Proactive load balancing across phases becomes data-driven rather than guesswork — you see exactly which outlets are pulling how much before a phase imbalance trips a breaker.
  • 0U Vertical Form Factor: Zero rack-unit footprint means this PDU mounts vertically in the side channels of a standard 19-inch rack without consuming a single U of server or switch space. In fully populated racks, that distinction is the difference between fitting the PDU and losing two units of revenue-generating compute.
  • 50/60 Hz Input Compatibility: Dual-frequency support (50/60 Hz) makes the APDU11350SM deployable across North American and European power infrastructure without hardware substitution — relevant for multinational enterprise deployments or colocation operators managing mixed-region equipment pools.
  • USB Port for Local Management: The single USB port provides a local console access path for initial configuration or recovery scenarios where the network management interface is unreachable — useful during commissioning or network outages without requiring a separate serial adapter.
  • RoHS Compliance: RoHS certification confirms hazardous substance restrictions are met, which matters for enterprise procurement teams with environmental compliance mandates or EU-region deployments subject to directive requirements.

Integration and Compatibility

The APDU11350SM integrates into environments running APC's EcoStruxure IT platform, enabling DCIM-layer monitoring alongside other APC and Schneider Electric infrastructure. The NMC3 card supports industry-standard protocols (SNMP, Modbus) that feed into third-party DCIM and power management platforms. With five Ethernet ports, this unit can participate in redundant management network topologies without external switches. The four outlet types (C13/C15/C19/C21) ensure broad compatibility with standard server PSUs, network switch power inputs, and specialty high-temperature equipment — reducing the need for adapter cords that complicate audits and introduce failure points. Consider pairing with a compatible APC UPS system upstream to provide the runtime buffer that a switched PDU cannot supply on its own.

Frequently Asked Questions

Q: What input voltage and phase configuration does the APDU11350SM require?

A: The APDU11350SM requires a 400V three-phase input at up to 60A, with 50/60 Hz compatibility. This is a 3PH unit — it is not compatible with single-phase circuits.

Q: How many outlets does the APDU11350SM provide, and what connector types are included?

A: It provides 42 AC outlets in four types: C13, C15, C19, and C21. This covers standard IEC server connections, high-temperature C15 applications, and high-current C19/C21 loads.

Q: Does the APDU11350SM support per-outlet switching, or only branch-level control?

A: The APDU11350SM is a switched metered outlet PDU, meaning it supports per-outlet switching — individual outlets can be remotely powered on, off, or cycled independently through the NMC3 management interface.

Q: What management platform does the APDU11350SM use, and how many network ports does it have?

A: It uses APC's NMC3 (Network Management Card 3) platform with five RJ-45 Ethernet ports, supporting network segmentation and out-of-band management topologies.

Q: Does the APDU11350SM take up rack unit space?

A: No. The APDU11350SM is a 0U device — it mounts vertically in a rack's side channel and consumes zero rack units, preserving all available U-space for compute and networking equipment.

Q: Is the APDU11350SM RoHS compliant?

A: Yes. The APDU11350SM carries RoHS compliance certification, meeting EU hazardous substance restrictions for deployments with environmental compliance requirements.

Eden Phillips
Eden Phillips

The APDU11350SM is the unit I recommend when a customer needs outlet-level switching at genuine three-phase scale — 34,600 VA across a 400V/60A feed is not a spec you find on entry-tier PDUs, and the NMC3 with five Ethernet ports puts this in a different class than most competitors' single-port management cards. If you're running a high-density compute row and need both granular control and real network management flexibility, this is where the hardware earns its position.

Technical Highlights:

  • 42 Mixed-Type Outlets: C13/C15/C19/C21 on one PDU eliminates adapter chains — C15 for high-temp switch gear, C19/C21 for high-current server PSUs, all on the same unit without retrofitting.
  • 34,600 VA / 60A Three-Phase Input: Headroom matters at high-density. Running at 60A on a 3PH 400V feed means you're well within safe operating range on a fully loaded AI inference or blade chassis rack without tripping breakers at peak draw.
  • 5x RJ-45 NMC3 Ports: Five management ports let you put this PDU on separate management VLANs or redundant management networks simultaneously — a real operational advantage in colo or multi-tenant environments where network isolation is contractually required.

Deployment Considerations:

  • This unit is 400V three-phase only — confirm your facility's power distribution provides 3PH at 400V before specifying. It is not field-configurable to single-phase or 208V operation.
  • At 56mm wide and 75mm deep in its 0U vertical profile, verify your rack's side-channel clearance before ordering — some third-party racks have narrower vertical mounting channels than APC Netshelter standards assume.

The APDU11350SM is best matched to European or multinational data center rows running high-density compute at 400V three-phase, where operators need per-outlet switching, live load metering, and a management network that can be properly segmented — colocation providers and enterprise data centers with strict change-management and remote-hands-reduction mandates are the primary fit.

Specifications
PDU types: Metered
Type: Three-phase
Rack capacity: 0U
Product colour: Black
AC outlets quantity: 42 AC outlet(s)
AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports: 5
USB ports quantity: 1
Management platform: NMC3
Nominal input voltage: 400 V
AC input frequency: 50/60 Hz
Maximum current: 60 A
Nominal output voltage: 400 V
Load capacity: 34600 VA
Number of phases: 3
Compliance certificates: RoHS
Width: 56 mm
Depth: 75 mm
Q&A
Reviews
Have Questions?

APC Netshelter Rack PDU Advanced Switched Metered Outlet 17.3KW 3PH 415V 30 - APDU11350SM

$6,985.00
$4,650.99

RELATED PRODUCTS

Save $2,283.01
APC Netshelter Rack PDU Advanced Switched Metered Outlet 17.3KW 3PH 415V 30 - AP
Add to Cart The item has been added

APC by Schneider Electric APDU10350SM

APC Netshelter Rack PDU Advanced Switched Metered Outlet 17.3KW 3PH 415V 30 - APDU10350SM

PC's three-phase vertical rack PDU built for high-density data center and network equipment rooms where per-outlet switching and metering are

    Usually Ships in 2-3 Weeks Free shipping over $499
    $6,825.00 $4,541.99 Save $2,283.01
    The item has been added Add to quote
    $6,825.00 $4,541.99 Save $2,283.01
    Save $2,283.01 Add to cart Add to quote
    Save $2,069.01
    APC Netshelter Rack PDU Advanced Metered Outlet 17.3KW 3PH 415V 30A 530P6 - APDU
    Add to Cart The item has been added

    APC by Schneider Electric APDU10350MO

    APC Netshelter Rack PDU Advanced Metered Outlet 17.3KW 3PH 415V 30A 530P6 - APDU10350MO

    3-phase, 415V/30A rack-mount power distribution unit delivering 17.3KW across 48 metered outlets — purpose-built for high-density rack environments

      Usually Ships in 2-3 Weeks Free shipping over $499
      $6,355.00 $4,285.99 Save $2,069.01
      The item has been added Add to quote
      $6,355.00 $4,285.99 Save $2,069.01
      Save $2,069.01 Add to cart Add to quote
      Save $2,098.01
      APC Netshelter Rack PDU Advanced Metered Outlet 17.3KW 3PH 415V 30A 530P6 - APDU
      Add to Cart The item has been added

      APC by Schneider Electric APDU11350MO

      APC Netshelter Rack PDU Advanced Metered Outlet 17.3KW 3PH 415V 30A 530P6 - APDU11350MO

      PC by Schneider Electric's advanced metered-outlet, three-phase rack PDU built for high-density data center and enterprise server rack environments

        Usually Ships in 2-3 Weeks Free shipping over $499
        $6,505.00 $4,406.99 Save $2,098.01
        The item has been added Add to quote
        $6,505.00 $4,406.99 Save $2,098.01
        Save $2,098.01 Add to cart Add to quote
        Save $2,687.01
        APC Netshelter Rack PDU Advanced Switched Metered Outlet 3PH 17.3KW 208V 60 - APDU11452SM
        Add to Cart The item has been added

        APC by Schneider Electric APDU11452SM

        APC Netshelter Rack PDU Advanced Switched Metered Outlet 3PH 17.3KW 208V 60 - APDU11452SM

        N advanced switched, metered rack Power Distribution Unit (PDU) designed for high-density data center environments

          Usually Ships in 2-3 Weeks Free shipping over $499
          $8,035.00 $5,347.99 Save $2,687.01
          The item has been added Add to quote
          $8,035.00 $5,347.99 Save $2,687.01
          Save $2,687.01 Add to cart Add to quote
          Save $3,106.01
          APC Netshelter Rack PDU Advanced Switched Metered Outlet 34.6KW 3PH 415V 60 - AP
          Add to Cart The item has been added

          APC by Schneider Electric APDU11450SM

          APC Netshelter Rack PDU Advanced Switched Metered Outlet 34.6KW 3PH 415V 60 - APDU11450SM

          PC's high-density, three-phase advanced switched metered outlet PDU built for enterprise data centers and large network equipment rooms where 34.6kW

            Usually Ships in 2-3 Weeks Free shipping over $499
            $9,290.00 $6,183.99 Save $3,106.01
            The item has been added Add to quote
            $9,290.00 $6,183.99 Save $3,106.01
            Save $3,106.01 Add to cart Add to quote

            System Design, Deployment & Technical Support

            Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

            Fixed scope • Fixed price

            System Design Assistance

            • Get help validating product compatibility
            • Coverage requirements
            • Storage planning and deployment architecture before you buy.
            Request Design Help

            Deployment & Configuration Support

            • Access fixed-scope support for rollout planning
            • User setup guidance
            • Migration and system standardization across single-site or multi-site deployments
            View Support Services

            Guides, Tools & Calculators

            • PoE requirements
            • Storage retention
            • Camera selection and deployment methodology
            Open Technical Resources