Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU11151SM is APC's high-density, zero-rack-unit switched metered outlet PDU rated for 5.0 kW single-phase 208V at 30A — purpose-built for dense data center cabinets, colocation deployments, and enterprise server rooms where per-outlet switching and individual circuit metering matter. Unlike basic metered PDUs that only report aggregate load, the APDU11151SM gives operators outlet-level on/off control and real-time monitoring through APC's APC by Schneider Electric NMC3 network management card platform, which is the same management architecture used across APC's enterprise rack power distribution lineup. The 0U vertical form factor keeps all 40 outlet positions accessible along the cabinet rail without consuming a single rack unit of usable space — a meaningful advantage in fully loaded racks.
The APDU11151SM integrates with APC's EcoStruxure IT and Data Center Expert platforms via the NMC3 interface, providing real-time power monitoring, environmental sensor support, and alert-based automation. SNMP v3 support means it can feed data into third-party DCIM and BMS platforms without requiring proprietary software. The five RJ-45 ports enable a cascaded PDU topology where an entire cabinet's worth of PDUs reports through a single switch port — pair this with managed network switches that support SNMP polling for a complete power visibility picture. Input plug type for the APDU11151SM is L6-30P, matching standard 208V/30A single-phase receptacles common in North American data centers; verify your existing PDPs (power distribution panels) or UPS output connections are L6-30 before ordering.
Q: What outlet types does the APDU11151SM provide, and how many of each?
A: The APDU11151SM provides 40 IEC outlets across four coupler types: C13, C15, C19, and C21. The C13 and C15 outlets serve standard and high-temperature server connections respectively, while the C19 and C21 outlets accommodate higher-draw equipment requiring 16A or 20A IEC connections.
Q: What is the input plug type and maximum load for the APDU11151SM?
A: The APDU11151SM uses an L6-30P input plug (208V, 30A single-phase) and has a rated load capacity of 4,992 VA. For continuous operation, plan to stay at or below 24A (80% of the 30A rating) to comply with electrical best practice.
Q: Does the APDU11151SM support remote outlet switching?
A: Yes. The APDU11151SM is a switched metered outlet PDU, meaning each outlet can be individually powered on, off, or rebooted remotely via the NMC3 network management interface — useful for remote power cycling of hung equipment without a physical site visit.
Q: What management protocols does the NMC3 platform on the APDU11151SM support?
A: NMC3 supports SNMP v1/v2c/v3, Modbus TCP, and HTTPS web interface, enabling integration with DCIM platforms, building management systems, and network monitoring tools. The five onboard RJ-45 Ethernet ports support cascaded PDU topologies to reduce upstream switch port consumption.
Q: Does the APDU11151SM take up rack unit space?
A: No. The APDU11151SM is a 0U vertical-mount PDU. Its 56mm-wide × 75mm-deep chassis mounts in the vertical zero-U channel of standard server cabinets, leaving all horizontal rack units free for equipment.
Q: Is the APDU11151SM RoHS compliant?
A: Yes, the APDU11151SM carries RoHS certification, confirming it is manufactured without restricted hazardous substances — a procurement requirement for many government, healthcare, and EU-destination deployments.

The APDU11151SM is the PDU I'd specify for any dense 208V cabinet where the operations team needs outlet-level granularity — not just aggregate branch metering. The 4,992 VA load capacity and 30A L6-30P input cover a fully loaded 42U cabinet of modern 1U servers comfortably, and the NMC3 platform means you're not bolting on a management layer after the fact; it's built in from day one.
Technical Highlights:
Deployment Considerations:
The APDU11151SM fits best in enterprise data center rows and co-location cabinets running 208V single-phase infrastructure where per-outlet remote switching is a day-two operational requirement — not an afterthought.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price