Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU11350MO is APC by Schneider Electric's advanced metered-outlet, three-phase rack PDU built for high-density data center and enterprise server rack environments where per-outlet power visibility is non-negotiable. Rated at 34,600 VA (17.3 kW) across a 415V / 30A three-phase input, this 0U unit slots into the vertical channel of a rack PDU deployment without consuming any rack unit space — keeping all 42 outlet positions available for compute or storage gear. Explore the broader APC by Schneider Electric power management catalog for complementary UPS and monitoring solutions.
The APDU11350MO integrates into APC EcoStruxure IT and Data Center Expert environments via the NMC3 platform, enabling centralized monitoring alongside UPS systems, environmental sensors, and other network management cards in the same infrastructure stack. The five RJ-45 ports support PDU daisy-chaining in multi-PDU rack configurations — a common topology in blade server deployments where two PDUs per rack (for A/B feed redundancy) are standard. For organizations using DCIM platforms beyond EcoStruxure, NMC3 supports SNMP v1/v2c/v3 and Modbus TCP, enabling integration with third-party management tools. The 530P6 input connector is specific — verify your facility's whip termination matches before ordering; this is not a standard NEMA-L input configuration.
Q: What input connector does the APDU11350MO use?
A: The APDU11350MO uses a 530P6 three-phase input connector, rated for 415V / 30A. This is an IEC 60309 format connector standard in European and international three-phase power infrastructure. Verify your facility whips terminate in a compatible 530P6 receptacle before ordering.
Q: How many outlets does the APDU11350MO provide, and what types?
A: The APDU11350MO provides 42 IEC outlets across four types: C13, C15, C19, and C21. This mixed outlet array supports standard servers (C13), high-temperature devices (C15), blade enclosures and high-draw equipment (C19/C20), and the highest-draw appliances requiring C21 connections.
Q: Does the APDU11350MO support remote outlet-level monitoring?
A: Yes. The metered-outlet architecture combined with the onboard NMC3 management card enables per-outlet power monitoring accessible remotely over the network via the five onboard RJ-45 ports. This supports capacity planning, anomaly detection, and chargeback reporting in multi-tenant environments.
Q: What is the total load capacity of the APDU11350MO?
A: The APDU11350MO is rated at 34,600 VA on a three-phase 415V / 30A input. For continuous operation, plan to load to approximately 80% of rated capacity (roughly 27,700 VA) to maintain safe operating margins and avoid nuisance tripping.
Q: Can multiple APDU11350MO units be daisy-chained for centralized management?
A: Yes. The NMC3 management platform includes five RJ-45 ports specifically to support PDU daisy-chaining within a rack column, reducing the number of independent network management connections required for multi-PDU deployments.
Q: Is the APDU11350MO RoHS compliant?
A: Yes. The APDU11350MO carries RoHS compliance certification, making it suitable for procurement in regulated industries and public sector data center environments that require environmental compliance documentation from hardware vendors.

When I spec the APDU11350MO into a high-density rack design, the first thing I check is the input connector — the 530P6 three-phase plug is not something you'll find on every facility's existing whip infrastructure, and a mismatch here stalls a rack commissioning entirely. Get that confirmed with the facilities team before the PDU ships.
Technical Highlights:
Deployment Considerations:
The APDU11350MO is the right call for European or international colocation deployments running IEC 60309 three-phase infrastructure where per-outlet metering and NMC3 remote management are required in the same unit — specifically in racks mixing blade servers, high-temperature networking gear, and high-draw storage that demand the full C13/C15/C19/C21 outlet range.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price