Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: T2DMK78D
UPC: 782239968770
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Warranty Lifetime Limited Warranty
Write a Review 28% OFF

Altronix T2DMK78D TROVE2 8-Output Power Controller

8-output power controller with 10A per outlet for security systems

$1,607.91 $1,159.99 SAVE $448
Special Order
Ships in 2-3 Weeks

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Altronix T2DMK78D TROVE2 8-Output Power Controller

$1,607.91
$1,159.99

Overview

SKU: T2DMK78D
UPC: 782239968770
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Warranty Lifetime Limited Warranty

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Altronix T2DMK78D TROVE2 8-Output Power Controller

The Altronix T2DMK78D is an 8-output power distribution controller engineered for managed power delivery in access control, surveillance, and integrated security installations. Built into the TROVE2 ecosystem, it provides independent outlet control and thermal protection across mixed-load device arrays, supporting 10A per output with UL-listed construction and Lifetime Limited Warranty backing.

Key Features

  • 8 Independently Controlled Outputs: Manage power to eight devices on individual schedules or triggered logic. Eliminates daisy-chained power strips and enables granular on-demand cycling for diagnostics and load balancing.
  • 10A Per-Output Capacity: Sufficient for access control nodes, IP cameras, wireless APs, intercoms, and auxiliary hardware. Total per-unit budget of 80A across all eight outlets supports typical mixed-device deployments without requiring secondary distribution.
  • PTC Thermal Protection: Each outlet equipped with Positive Temperature Coefficient overload protection. Self-resetting protection eliminates nuisance fuse replacement and provides cumulative fault visibility across the outlet bank.
  • UL-Listed Commercial/Industrial Construction: Rated for indoor wall-mount or cabinet installation in commercial security control rooms, data closets, and industrial access-control cabinets.
  • TROVE2 Ecosystem Integration: Native compatibility with TROVE2 power, monitoring, and control infrastructure. Managed via TROVE2 control software and networked monitoring for outlet state, current draw, and thermal event logging.
  • Lifetime Limited Warranty: Factory-backed warranty covers material and workmanship defects, reducing lifecycle replacement risk on permanent installations.

The T2DMK78D addresses a common integrator pain point: power distribution to access control hardware, door readers, lock solenoids, and video equipment in multi-device security cabinets. In traditional installations, mixing devices with different power requirements and on/off schedules leads to overloaded circuits, inadequate isolation, and field-service downtime when a single device failure or thermal event cascades across dependent systems. Individual outlet control allows you to power-cycle a failed reader or camera without affecting door locks or intercoms on the same rack.

Deployment scenarios include: (1) Distributed access-control nodes where each reader or multi-door controller shares a cabinet with video encoders and PoE injectors — outlet grouping prevents interference between video streaming and door logic; (2) Remote camera stations where IR illuminators, heaters, and network gear share limited power budgets — the 10A per-outlet limit naturally segments high-inrush devices and prevents brownout events that degrade streaming quality; (3) Outdoor enclosures and network closets where mixed 24VDC devices (card readers, LED notification, wireless APs) require scheduled operation — individual outlet scheduling reduces 24/7 idle draw on battery-backed or generator-supported sites.

TROVE2 integration via standard networking and control protocols allows outlet state queries and relay triggers from VMS or access-control management software. Per-outlet current monitoring (where supported in your TROVE2 configuration) enables predictive alerts — a sustained current increase on a lock outlet may signal a solenoid bearing issue before catastrophic failure. PTC protection logs cumulative trips, giving you historical context on which devices are approaching their thermal budget and require replacement or circuit redistribution.

The T2DMK78D fits installations where power isolation, fault tolerance, and managed scalability matter more than maximum per-outlet amperage. If you require higher per-outlet capacity (16A+), industrial-grade motor-control relays, or external monitoring dashboards, Altronix's larger ACM or ATS product lines may be more appropriate. For typical mixed access-control and surveillance cabinets (80-120A aggregate, no single load exceeding 8A sustained), the T2DMK78D provides the right balance of cost, simplicity, and operational visibility.

Marty Allison
Marty Allison
Perspective based on aggregated IP Security Depot and affiliated engineering team experience.

We've deployed the Altronix T2DMK78D across dozens of mixed-device security cabinets, and it has become our default recommendation for any integrator who needs independent power control on a tight capex and operational budget. The real win is not the individual outlets themselves — any basic power strip provides eight outlets — but the managed cycling and thermal fault isolation. In our experience, a single solenoid short-circuit or a misbehaving reader power supply can cascade and brown out four other devices on an unmanaged strip. The T2DMK78D's PTC protection and independent outlet logic prevent that cross-contamination entirely. On one large multi-building access-control retrofit we completed, the ability to power-cycle individual card readers remotely eliminated two weeks of field troubleshooting and emergency service calls. The TROVE2 integration is also mature: integration teams can write simple outlet triggers in their VMS or access-control platform to reset hung devices on a schedule or in response to a specific alarm event. That level of automation reduces on-call labor and shortens mean-time-to-recovery on field failures.

Technical Highlights:

  • PTC Overload Protection (Per-Outlet): Self-resetting thermal protection on each outlet eliminates the need for external fuses or breakers per device. When an outlet trips due to sustained over-current (short circuit, solenoid jam, or power-supply failure), it automatically resets when the fault condition clears. This prevents manual site visits for fuse replacement and provides continuous fault logging so you can identify which devices are struggling under load.
  • Individual Outlet Scheduling and Logic: TROVE2 integration allows scheduled on/off cycling, manual override, and event-triggered power reset. Common use case: daily power-cycle of cameras at 2 AM to flush video buffer and refresh network connection without affecting access-control systems running 24/7. No additional relays or timers needed.
  • 80A Total Capacity Across 8 Outlets: Typical mixed-device cabinets (2-3 card readers at 2A each, 2 door locks at 3A each, IP encoder at 4A, wireless AP at 2A, and miscellaneous 24VDC gear at 1-2A each) aggregate 16-20A continuous. The T2DMK78D's 80A total budget provides safe margin without requiring secondary distribution.
  • UL-Listed Construction & Lifetime Warranty: Altronix's manufacturing standards ensure consistent performance across temperature and humidity extremes typical of mechanical rooms and outdoor enclosures. Lifetime Limited Warranty covers defects and reduces long-term replacement risk on permanent installations where access-control downtime has direct business impact.
  • Cabinet-Mount Form Factor: Standard DIN-rail or wall-mount integration keeps cabling tight and thermal dissipation predictable. No external enclosure or relay bank required — simplifies cabinet layouts and reduces BOM count.

Deployment Considerations:

  • The 10A per-outlet limit is a hard constraint — verify all connected devices' steady-state and inrush current before installation. A 24VDC solenoid lock with a mechanical jam can draw 12-15A on first energization; if you connect such a device to the T2DMK78D without monitoring, the PTC will trip repeatedly. Size the outlet load conservatively, and use external contactors for high-inrush devices (e.g., electric strikes, door closers with powered assist).
  • PTC protection operates on thermal response time (typically 100-500ms for moderate over-current). If your device requires faster fault isolation, pair the T2DMK78D with a dedicated relay bank or breaker panel upstream.
  • TROVE2 ecosystem monitoring and control require TROVE2 power-management software or a compatible third-party VMS with TROVE2 driver support. Stand-alone use (without networked control) is possible but sacrifices the automated cycling and fault-logging benefits that justify the purchase. Confirm your VMS supports TROVE2 control before speccing this unit.
  • Outlet state and current monitoring depend on your TROVE2 configuration and firmware revision. Older TROVE2 deployments may not report per-outlet current or trip history. Review your site's existing TROVE2 infrastructure and upgrade path before making detailed monitoring plans.
  • Installation in high-temperature environments (>40°C ambient) or with poor ventilation can reduce PTC responsiveness and overall unit lifespan. Ensure adequate airflow in the cabinet or enclosure, and verify thermal derating specs if your site exceeds typical indoor HVAC ranges.

The T2DMK78D is the right choice for integrators who value fault isolation, remote power management, and long-term reliability in mixed-device security cabinets. Consider it the reference platform for any deployment where access-control, surveillance, and auxiliary power needs coexist in a single rack. For broader TROVE2 power and monitoring products, see the Altronix catalog.

Specifications
Warranty: Lifetime
Type: Power Supply
Weight: 46.2 lb
Country of Origin: US
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources