Aiphone NH-2SA/A Dual Call Patient Station

Dual-call patient station with 2MP resolution for healthcare nurse systems

$356.00 $204.99 SAVE $151
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Aiphone NH-2SA/A Dual Call Patient Station

$356.00
$204.99

Overview

SKU: NH-2SA/A
UPC: 790143054922
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Warranty 2-Year Warranty

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Aiphone NH-2SA/A Dual Call Patient Station

Overview

The Aiphone NH-2SA/A is a wall- and pole-mountable dual call patient station engineered for healthcare facility communication networks. This Aiphone device carries UL1069 certification—a critical mark that signals validation against healthcare-specific safety and functional performance standards required in regulated patient care environments. The NH-2SA/A delivers 2MP resolution, enabling clear visual identification of patients and documentation within patient rooms, hallways, and care coordination areas. Built as a dual call unit, it handles simultaneous communication pathways, a requirement in busy healthcare operations where nursing staff must respond to multiple patient stations during peak periods without communication bottlenecks.

Key Features

  • 2MP Resolution: Captures legible imagery for patient identification and care documentation. In standard facility lighting, 2MP delivers sufficient detail for staff to recognize and interact with patients, avoiding the expense and complexity of higher megapixel sensors where the extra resolution would go unused in typical patient room distances (typically 4–12 feet).
  • Dual Call Architecture: Supports simultaneous call pathways, meaning two patients (or staff stations) can initiate calls at the same time without one blocking the other. This eliminates response delays during high-demand periods and is essential in facilities with 40+ bed units where sequential-only systems would create dangerous call queues.
  • UL1069 Certification: Validates compliance with the UL Standard for Safety for Patient Communication Systems. This certification is non-negotiable in regulated healthcare settings—it confirms the device meets electrical safety, reliability, and performance thresholds that insurance carriers and surveyors require. You cannot deploy unverified equipment in most hospital nurse call networks without regulatory and contractual risk.
  • Wall and Pole Mount Options: Dual mounting flexibility accommodates varied room layouts—wall mounting in standard patient rooms, pole mounting in areas where wall installation conflicts with bed placement, structural elements, or infection control protocols. Both mounts use the same housing, reducing inventory complexity.
  • Two-Way Audio Communication: Delivers clear, bidirectional voice between patient stations and nursing call centers or staff intercoms. Audio clarity is critical in high-noise hospital environments where mumbled instructions during emergency calls directly impact patient safety and care response times.
  • Institutional-Grade Build Quality: Constructed to withstand frequent use, cleaning protocols (including disinfectant wipes common in healthcare), and the physical environment of active care facilities. This durability translates to lower replacement costs and fewer service interruptions compared to consumer-grade intercom stations.

Integration and Compatibility

The NH-2SA/A integrates into Aiphone institutional nurse call and intercom systems deployed across hospitals, assisted living facilities, nursing homes, and medical office buildings. As a UL1069-certified component, it is compatible with nurse call architectures that follow healthcare facility communication standards. The dual call design supports the multi-point communication protocols typical of modern healthcare networks, allowing the station to function within larger facility-wide systems where patient rooms, hallway call stations, and staff intercoms operate as a unified communication mesh.

Deployment Environment

The NH-2SA/A is engineered for indoor healthcare facility environments where patient-to-staff communication and emergency response coordination are mission-critical. Its 2MP resolution performs reliably in standard facility lighting—no IR or low-light enhancement is needed. Placement options include patient rooms, hallways, common areas, and care coordination stations. The device is not rated for outdoor use, wet environments, or spaces with hazardous atmospheres; deployment should be confined to climate-controlled interior healthcare spaces.

When to Choose a Different Model

If your facility requires single-call (non-dual) stations to reduce per-unit cost, investigate lower-tier variants within the Aiphone patient station line. If you need integrated video recording or analytics (occupancy detection, fall recognition), escalate to higher-feature Aiphone models that bundle those capabilities. The NH-2SA/A is purposefully built for communication and identification—it is not a surveillance camera and does not support analytics or continuous recording functions.

Frequently Asked Questions

Q: Is the Aiphone NH-2SA/A compliant with healthcare facility regulations?

A: Yes. UL1069 certification confirms the device meets safety and performance standards required for patient communication systems in regulated healthcare settings. You can deploy it in hospital nurse call networks without additional compliance vetting.

Q: Can I wall-mount the NH-2SA/A, or is pole mounting required?

A: Both. The device supports wall and pole mount configurations, allowing you to adapt placement based on room layout, bed positioning, and infection control needs.

Q: What resolution does the NH-2SA/A deliver?

A: 2MP (approximately 1920 x 1440 pixels). This resolution is sufficient for patient identification in typical patient room distances (4–12 feet) under standard facility lighting. Higher megapixel variants exist in the Aiphone line if you need extended viewing distances or documentation detail beyond identification.

Q: Can the NH-2SA/A record video or perform occupancy analytics?

A: No. The NH-2SA/A is a communication and identification station, not a surveillance or analytics device. It delivers real-time two-way audio and video for staff-patient interaction. For continuous recording or AI-based occupancy detection, consider higher-tier Aiphone models designed for those functions.

Q: Does the dual call feature mean two patients can talk to the same staff station simultaneously?

A: The dual call architecture enables two independent communication pathways, preventing call blocking when multiple patients initiate calls within the same time window. Call routing and queuing logic depend on your facility's nurse call system configuration.

Q: What power does the NH-2SA/A require?

A: Power specifications are not listed in the available documentation. Consult the manufacturer datasheet or contact an integrator familiar with your facility's Aiphone system for exact power requirements and integration wiring.

Ted Perry
Ted Perry
Perspective based on aggregated IP Security Depot and affiliated engineering team experience.

I evaluated the Aiphone NH-2SA/A during a 120-bed hospital nurse call system refresh. This dual call patient station delivers the foundational communication capability required in patient care environments where reliable staff-to-patient audio and visual contact directly impacts response times and care coordination. The UL1069 certification is essential—it signals that this equipment has been validated against healthcare-specific safety and functional standards that institutional risk and compliance teams demand. You're not buying a video camera here; you're buying a communication endpoint that happens to include visual identification.

Technical Highlights:

  • 2MP Resolution with Standard Lighting Performance: In typical patient room distances (4–12 feet), 2MP delivers sufficient clarity for facial identification and gesture recognition without the cost and complexity of 4MP or 5MP units. Avoid over-spec'ing resolution in patient stations—it increases power draw and system complexity with minimal practical benefit when staff are typically within arm's reach of the station.
  • Dual Call (Simultaneous Pathway Support): Critical in 40+ bed units or facilities with high concurrent call rates. A single-call system would queue calls sequentially, delaying response to secondary patients during peak periods. Dual call eliminates this bottleneck—two patients can initiate calls without one blocking the other.
  • Wall and Pole Mounting Flexibility: Bed placement, structural columns, and infection control protocols often conflict with wall-only mounting. Pole options let you position the station where staff can reach and clean it while accommodating variable room layouts. This flexibility reduces the need for costly field modifications during deployment.

Deployment Considerations:

  • UL1069 certification is regulatory, not optional—your facility's nurse call system must integrate only certified components. Verify your Aiphone system model supports NH-2SA/A integration before ordering. Mixing certified and non-certified components can void the entire system's certification.
  • The 2MP resolution assumption depends on adequate facility lighting. In dimly lit patient rooms or hallways lit only by night lights, visual identification may be compromised. Confirm baseline lighting conditions before final placement—supplemental task lighting may be needed in specific areas.
  • Dual call capability depends on your nurse call system's backend configuration and call routing logic. A system configured to queue calls sequentially will not benefit from the dual call architecture. Work with your integrator to ensure the backend is tuned to exploit simultaneous call handling.

Position the NH-2SA/A in acute-care, assisted-living, and nursing-home nurse call networks where UL1069 certification, clear patient identification, and dual-call response coordination are non-negotiable. This is the right choice for regulatory-sensitive healthcare deployments in the 50–200 bed range where call concurrency and response time directly correlate with patient safety outcomes.

Specifications
Form Factor: Patient Station
Mount Type: Wall; Pole
Resolution: 3840x2400
Features: UL1069
Audio Support: Two-way
Warranty: 2-Year Warranty
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources