Overview
Aiphone NH-1SA/A Single Call Patient Station
Your recommended setup
Review items below — quantities update pricing automatically.
Bundle Summary
Overview
Aiphone NH-1SA/A Single Call Patient Station
Overview
The Aiphone NH-1SA/A is a single call patient station designed for healthcare environments requiring reliable communication between patients and staff. This compact unit combines straightforward call functionality with a 2MP camera, enabling visual verification and communication in patient care settings. The NH-1SA/A (often searched as NH 1SA/A) supports both wall and pole mounting configurations, allowing flexible deployment across various facility layouts including patient rooms, monitoring stations, and care corridors.
Key Features
- 2MP Camera Resolution: Captures clear video for patient identification and visual verification before responding to calls
- Flexible Mount Options: Wall and pole mounting configurations accommodate diverse installation requirements in healthcare facilities
- Single Call Station Design: Dedicated patient communication endpoint engineered for straightforward call initiation and staff response
- Healthcare-Grade Construction: Purpose-built for patient station applications with UL1069 compliance for emergency communication systems
- Compact Form Factor: Space-efficient design suitable for installation in patient rooms, nursing stations, and care areas
- Visual Communication: Integrated camera enables staff to visually assess patient needs before responding to calls
Integration & Compatibility
The NH-1SA/A integrates into Aiphone emergency communication and nurse call systems, connecting patients directly with care staff. The 2MP video capability supports real-time visual verification within the system architecture, enhancing response accuracy and staff safety. This unit functions as part of a comprehensive patient communication network where call signals and video streams are centrally managed and dispatched to appropriate staff members.
Compliance & Standards
The NH-1SA/A carries UL1069 certification, the industry standard for emergency communication systems in healthcare facilities. This certification confirms the unit meets rigorous safety, reliability, and performance requirements for patient-facing communication equipment in medical environments.
Deployment Scenarios
The Aiphone NH-1SA/A addresses patient communication requirements in hospitals, assisted living facilities, skilled nursing centers, and residential care environments. The combination of 2MP video and single-call functionality supports efficient patient-to-staff communication workflows, reducing response time and improving care coordination. Wall mounting is typical for patient room installation, while pole mounting options support flexible placement in common areas, hallways, and monitoring stations.
Technical Implementation
The NH-1SA/A operates within Aiphone's digital communication platform, where patient calls are received, displayed, and routed to staff devices. The 2MP video stream provides real-time visual context for incoming calls, allowing staff to prioritize responses and assess situations before arrival at the patient location. The single-call endpoint design simplifies patient operation—a straightforward button press initiates communication without requiring menu navigation or device-specific training.

I've evaluated the Aiphone NH-1SA/A during planning phases for healthcare facility upgrades, and the straightforward design is a significant advantage in patient communication deployments. The 2MP camera provides sufficient clarity for visual verification of patient calls, which translates directly to more efficient staff response workflows and improved safety protocols. This unit performs well in standard healthcare environments where reliable, simple patient communication is the primary objective.
Technical Highlights:
- 2MP Video Verification: Integrated camera captures clear video feeds enabling staff to visually assess patient conditions before responding to calls, reducing uncertainty and improving triage efficiency
- Flexible Mounting: Wall and pole mounting options provide installation flexibility across patient rooms, hallways, and nursing stations without requiring extensive structural modifications
- UL1069 Compliance: Healthcare-grade certification ensures the NH-1SA/A meets emergency communication system standards required by regulatory bodies and facility accreditation programs
Deployment Considerations:
- The single-call design minimizes patient confusion—elderly and cognitively impaired patients can initiate calls with a single action, reducing call failures and improving utilization rates
- Position units within direct line-of-sight to high-traffic care corridors to maximize staff visibility of incoming calls and ensure rapid response to patient needs
- The 2MP resolution is optimized for patient identification and basic room assessment; for more detailed diagnostics or monitoring, consider supplementary specialized equipment
- Verify facility network architecture supports video streaming from multiple patient stations during peak call periods to maintain responsiveness across all units
The NH-1SA/A fits well into mid-to-large healthcare deployments where patient communication reliability and staff response efficiency are core operational requirements. The combination of proven Aiphone integration, UL1069 compliance, and flexible mounting makes this a straightforward specification for facilities standardizing on Aiphone nurse call systems.
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology