Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

StarTech FAN6X1TX3 60mm Ball Bearing Chassis Cooling Fan

Overview

The StarTech FAN6X1TX3 is a 60mm ball bearing fan designed to add supplemental airflow inside PC chassis, NVR enclosures, and similar equipment cabinets where thermal headroom matters. Running at a fixed 4000 RPM and moving 15.49 CFM of air, it connects via a standard 3-pin Tx3 connector on a 12V DC supply — a straightforward drop-in for most motherboards and case fan headers without any special wiring or adapter. If you are managing a rack of recording servers or a cluster of edge computing appliances in a surveillance closet and need to push hot air out of a tight enclosure, this fan delivers a meaningful airflow increase for under 2 watts of draw.

Key Features

  • 4000 RPM Fixed Speed: Running continuously at 4000 RPM, the FAN6X1TX3 delivers consistent, predictable airflow regardless of thermal load fluctuation — useful in always-on environments like NVR rooms where you cannot afford thermal throttling events during a recording cycle.
  • 15.49 CFM Airflow: For a 60mm fan, 15.49 CFM is a solid figure that makes a real difference inside constrained chassis. More CFM means more heat-laden air displaced per minute, which directly extends component lifespan in enclosed deployments.
  • Ball Bearing Construction: Ball bearing fans last significantly longer than sleeve bearing alternatives under continuous 24/7 operation — the design tolerates heat and horizontal or vertical mounting equally well. In equipment that runs without shutdown for months or years, bearing type is not a cosmetic spec.
  • 28 dBA Noise Level: At 28 dBA, this fan is audible in a quiet office but unremarkable in a server room or equipment closet. If noise is a constraint (e.g., a reception-area NVR cabinet), plan accordingly. If the hardware lives in a dedicated comms room, 28 dBA will go unnoticed.
  • 1.92W Power Consumption: Drawing only 160mA at 12V DC, this fan adds essentially nothing to your system power budget. In multi-fan configurations — say, three or four added to a high-density chassis — total added load still stays well under 10W.
  • 3-Pin Tx3 Connector: The Tx3 connector is backward compatible with standard 3-pin motherboard fan headers. No speed control via PWM, but the connector seats securely and is the correct interface for the majority of case fan headers found on NVR motherboards and commodity server boards.
  • -10°C to 80°C Operating Range: The rated operating temperature of -10 to 80°C means it remains functional in cold unheated equipment rooms in winter and in chassis where internal temperatures run high — both realistic conditions in security infrastructure deployments.
  • 60mm Form Factor: At 60mm square, this fan fits the standard 60mm mounting pattern used on many chassis side panels, rear exhaust positions, and bracket mounts. Verify your chassis accepts a 60mm fan before ordering — this is not a universal fit across all enclosure sizes.

Integration and Compatibility

The FAN6X1TX3 connects to any 3-pin fan header supplying 12V DC. It is not PWM-controlled (that requires a 4-pin header), so speed will not vary with thermal load — it runs at full 4000 RPM continuously. This is acceptable in dedicated equipment rooms but worth noting if the host system uses fan speed monitoring software that expects a variable RPM signal. The 60mm mounting pattern is a standard chassis dimension, but confirm the target enclosure actually has a 60mm fan bay or bracket before purchase. Suitable for use in NVR chassis, edge server appliances, industrial PCs, and similar always-on security infrastructure where supplemental airflow extends hardware reliability.

Frequently Asked Questions

Q: What connector does the FAN6X1TX3 use, and is it compatible with standard motherboard fan headers?

A: The FAN6X1TX3 uses a 3-pin Tx3 connector, which is compatible with standard 3-pin motherboard and chassis fan headers. It does not support 4-pin PWM headers for variable speed control — it runs at a fixed 4000 RPM.

Q: What is the airflow rating of the FAN6X1TX3?

A: The FAN6X1TX3 moves 15.49 CFM at its rated 4000 RPM operating speed.

Q: How loud is the FAN6X1TX3?

A: The rated noise level is 28 dBA. This is noticeable in a quiet room but unremarkable in a server room or dedicated equipment closet.

Q: What is the warranty on the FAN6X1TX3?

A: The FAN6X1TX3 carries a 2-year manufacturer warranty.

Q: Is the FAN6X1TX3 suitable for 24/7 continuous operation?

A: Yes. The ball bearing design is well-suited to continuous 24/7 operation and tolerates both vertical and horizontal mounting orientations. It is rated for operating temperatures from -10°C to 80°C.

Q: How much power does the FAN6X1TX3 consume?

A: It draws 160mA at 12V DC for a total power consumption of 1.92W — minimal impact on system power budgets even in multi-fan configurations.

Ted Perry
Ted Perry

The spec that matters most here is the ball bearing construction — in 24/7 security infrastructure environments, I have watched sleeve bearing fans fail inside NVR chassis well before the drives or compute hardware shows any signs of wear. The FAN6X1TX3 addresses that by using a ball bearing rated across a -10°C to 80°C operating envelope, which covers the realistic internal temperature range of a working NVR or edge appliance even in a warm equipment room.

Technical Highlights:

  • 4000 RPM / 15.49 CFM: Consistent full-speed airflow without thermal-dependent variation — at 4000 RPM you are moving 15.49 CFM continuously, which is the right profile for chassis positions where the goal is steady exhaust rather than reactive cooling.
  • 1.92W Draw: At 160mA on 12V DC, deploying three or four of these in a high-density chassis adds under 8W total — negligible on any modern PSU and no impact on UPS runtime calculations for security equipment rooms.
  • 28 dBA: Audible but not disruptive. This rating is appropriate for any dedicated comms room or equipment closet — if the fan is going into a mixed-use office space with open equipment racks, factor in the noise floor before committing.

Deployment Considerations:

  • Confirm the target chassis has a 60mm fan bay or bracket before ordering — the 60mm form factor is common but not universal, and forcing a wrong-size fan into an enclosure with adapters introduces vibration and reduces airflow efficiency.
  • The 3-pin Tx3 connector runs at fixed 4000 RPM with no PWM speed control. If your monitoring software flags a missing PWM tach signal as a fan fault, you will need to configure that header as a DC fan or disable the RPM alarm for that zone.

The FAN6X1TX3 is the right pick for adding exhaust capacity to a tight 1U or 2U NVR chassis in a surveillance equipment closet where the box runs continuously and thermal margin is thin — especially in summer months when ambient room temperatures climb and component temperatures follow.

Specifications
Fan Bearing Type: Ball Bearing
Air Flow Rate: 15.49 CFM
Noise Level: 28 dBA
Fan RPM: 4000
Connector Type: 3-pin Tx3
Input Voltage: 12V DC
Input Current: 160mA
Power Consumption: 1.92W
Operating Temperature: -10 to 80
Product Length: 60 mm
Product Width: 1 cm
Product Height: 6 cm
Weight: 28 g
Warranty: 2 Years
Brand: StarTech
MPN: FAN6X1TX3
Type: Mounting Bracket
Power: 12V DC
Q&A
Reviews
Have Questions?

StarTech ADD Additional Chassis Cooling With A 60MM - FAN6X1TX3

$12.29
$8.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources