CyberPower Blanking Panels, Tooless Installation, 10PCS PER Pack, 5-YR WTY
Pack of ten 19-inch, 1U blanking panels designed for rack enclosures
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The CyberPower CRA11001 is a six-fan roof-mounted cooling panel designed for 42 to 47 inch deep rack enclosures. It delivers 580 CFM of airflow using 120 VAC high-performance fans, making it suitable for surveillance NVR deployments, network equipment stacks, and other heat-sensitive electronics in secure server rooms. The unit comes ready to mount with a 6.5 ft power cord terminating in a standard NEMA 5-15P plug—no special wiring required.
The CRA11001 requires only a standard 120 VAC electrical outlet and sufficient roof space on a compatible 42–47" deep enclosure. There is no network connectivity, no management software, and no integration with VMS or IPAM systems—it operates independently. Pair this with your existing PDU or UPS outlet strip. If your surveillance rack already has a rear exhaust fan or blanking panel, verify that the CRA11001 doesn't create competing airflow patterns; in most cases, roof extraction and rear extraction work complementarily. For racks deeper than 47 inches or non-standard geometry, verify mounting clearance before purchase.
Operating input voltage is 110–120 VAC at 50–60 Hz, standard for North American deployments. The unit weighs 12.6 lb and measures 13.78 x 2.01 x 22.05 inches, requiring approximately 14 inches of clearance above the enclosure for fan intake. Metal construction provides durability in typical server-room conditions; no special humidity or dust-suppression requirements beyond standard data center practices. Shipping weight is 13.4 lb.
1x CRA11001 fan panel, 1x NEMA 5-15P power cord (6.5 ft), 1x mounting hardware kit for roof installation.
Q: Can I install the CRA11001 on an enclosure shallower than 42 inches?
A: No. The CRA11001 is designed for 42 to 47 inch deep enclosures. Using it on shallower models risks improper mounting, reduced stability, and airflow bypass. Verify your enclosure depth before ordering.
Q: Does the CRA11001 require network management or software?
A: No. The CRA11001 is a passive cooling device. It operates via the lighted on/off power switch and does not integrate with VMS, SNMP, or any management system. Airflow is constant whenever power is applied.
Q: What's the warranty on the CRA11001?
A: 2-year manufacturer warranty covering defects in materials and workmanship. Proof of purchase and original serial number are typically required for warranty claims.
Q: How loud is 51 dBA?
A: Approximately the volume of background conversation in a quiet office or a refrigerator. At 1.5 meters distance, the six fans combined produce this level. In an enclosed server room with closed doors, noise is generally acceptable. In shared spaces, consider your facility's acoustic environment.
Q: Can I daisy-chain multiple CRA11001 units for larger enclosures?
A: Technically yes, but verify with your enclosure manufacturer that roof load limits and airflow patterns support dual units. Each CRA11001 requires its own 120 VAC outlet. Dual units on the same enclosure may create pressure imbalances if not spaced correctly.
Q: What happens if I exceed the 110–120 VAC input range?
A: Operating outside the specified 110–120 VAC range risks motor damage or failure. Use a voltage regulator or confirm your outlet is within tolerance before connecting the unit. Most North American circuits deliver 115–120 VAC under normal conditions.

I've specified the CRA11001 in several surveillance NVR deployments where continuous recording across 16–32 cameras pushes thermal load hard. The 580 CFM airflow is the real spec to focus on—that's roughly 10 cubic feet of air per second pulling heat out of the cabinet. Combined with a rear exhaust fan, you're looking at active hot-aisle containment without the cost of in-frame cooling modules.
Technical Highlights:
Deployment Considerations:
Best fit: multi-camera NVR racks in secure server rooms where you control the thermostat and can afford steady-state cooling. Skip this if your enclosure is non-standard depth or if you need networked fan control integrated with a building management system.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more CyberPower products? Shop the full CyberPower catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price