Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: NPD-6001-IBT
UPC: 800549625081
Condition: New
Write a Review 0% OFF

Bosch 60W IEEE 802.3BT SINGLE PORT 20 60VDC INPUT INDOOR INDUSTRIAL TAA COMPLIANT - NPD-6001-IBT

Bosch NPD-6001-IBT 60W 802.3bt Industrial PoE InjectorOverviewThe Bosch NPD-6001-IBT is a single-port, 60W IEEE 802.3bt (PoE++) industrial injector de…

$501.00 $500.99 SAVE $0
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Bosch 60W IEEE 802.3BT SINGLE PORT 20 60VDC INPUT INDOOR INDUSTRIAL TAA COMPLIANT - NPD-6001-IBT

$501.00
$500.99

Overview

SKU: NPD-6001-IBT
UPC: 800549625081
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Bosch NPD-6001-IBT 60W 802.3bt Industrial PoE Injector

Overview

The Bosch NPD-6001-IBT is a single-port, 60W IEEE 802.3bt (PoE++) industrial injector designed for demanding environments where standard PoE midspans fall short. With a wide-range DC input of 20–60 VDC, it accepts power from solar arrays, battery banks, UPS systems, and distributed DC grids — making it the right tool when your power source isn't a standard AC outlet. The guaranteed 60W PoE output covers the full Class 4 and Class 5 device roster: PTZ cameras, multi-sensor units, high-draw access control panels, and VoIP endpoints that can't run on 802.3at. TAA compliance means it clears federal procurement requirements without exceptions or waivers.

Key Features

  • 60W Guaranteed PoE Output (IEEE 802.3bt): Most injectors advertise peak wattage — the NPD-6001-IBT specifies 60W guaranteed at the port. High-draw PTZ cameras and multi-sensor panoramic units that stall or reset under 802.3at finally stay running reliably.
  • 20–60 VDC Wide-Range Input: Accepts anything from a 24V industrial DC bus to a 48V telecom rack to a 60V solar/battery array. You're not hunting for an AC source in a remote cabinet or rooftop enclosure — wire it directly to whatever DC is available on site.
  • -40°C to 75°C Operating Range: Rated for -40°F to 167°F ambient, this unit survives unheated outdoor enclosures in northern climates and hot rooftop cabinets in summer without derating. Paired with a -40°C to 85°C storage range, it ships and stores without babysitting.
  • Single-Port 10/100/1000 Mbps Pass-Through: Full Gigabit data throughput on shielded RJ-45 (EIA 568A/568B compatible) means no bandwidth bottleneck for 4K or multi-stream cameras. One port, one device, full bandwidth — no shared backplane to contend with.
  • TAA Compliant: Sourced to meet Trade Agreements Act requirements. Federal, state, and municipal projects with domestic-sourcing mandates can spec this unit without triggering a compliance flag at the procurement desk.
  • 170,000-Hour MTBF at 25°C: That's just under 20 years of rated mean time between failures — relevant for installations where return visits are expensive (remote towers, buried enclosures, high-ceiling warehouses). Fewer unplanned replacements means lower lifecycle cost.
  • 32 BTU/h Maximum Heat Loss at 60 VDC: Minimal thermal output at full load means it co-locates cleanly in tight enclosures without forcing an oversized thermal management design. A well-ventilated NEMA box is sufficient; forced air is not required.
  • RoHS / WEEE / CE Compliant + UL508 / UL/EN/IEC 60950-1 Safety: Meets industrial control equipment safety standards (UL508) alongside IT equipment standards. FCC Part 15 Class A and EN 55032 Class A emissions ratings keep it legal in commercial and light-industrial RF environments.

Integration & Compatibility

The NPD-6001-IBT (often searched as NPD 6001 IBT) integrates directly into any IEEE 802.3bt-compliant powered device — no configuration required on the injector itself. The shielded RJ-45 connector supports both T568A and T568B wiring, so existing structured cabling installs don't need re-termination. PoE pin assignment follows the standard 802.3bt four-pair scheme: pairs 1/2 and 7/8 carry the negative rail, pairs 3/6 and 4/5 carry the positive rail at 55 VDC output — verify your PD's power sourcing equipment (PSE) polarity acceptance before deploying in non-standard cabling plants.

The wide DC input range makes this injector a natural fit for IP camera deployments powered off solar or backup battery systems, edge computing nodes in PoE network architectures, and high-power PTZ installations where the switch's per-port PoE budget is insufficient. Integrators building NVR-based systems with high-wattage edge devices will find the guaranteed 60W output eliminates the guesswork around power delivery. For more on matching PoE wattage to camera and device requirements, the PoE planning guide covers Class 4 through Class 8 load matching in detail. When mounting in outdoor enclosures, pair with an appropriate industrial housing rated for the site's environmental conditions.

Frequently Asked Questions

Q: What input voltage range does the NPD-6001-IBT accept?

A: The NPD-6001-IBT accepts 20–60 VDC input, covering 24V industrial DC buses, 48V telecom rails, and solar/battery arrays up to 60V. It does not accept AC input directly.

Q: How much PoE power does the NPD-6001-IBT deliver to a connected device?

A: It delivers 60W guaranteed at 55 VDC output on the PoE port, compliant with IEEE 802.3bt (Type 3). This covers Class 4 and Class 5 powered devices including high-draw PTZ cameras and multi-sensor units.

Q: Is the NPD-6001-IBT TAA compliant?

A: Yes. The NPD-6001-IBT is TAA (Trade Agreements Act) compliant, making it eligible for federal, state, and municipal procurement projects with domestic-sourcing requirements.

Q: What is the operating temperature range of the NPD-6001-IBT?

A: The unit operates from -40°C to 75°C (-40°F to 167°F), suitable for unheated outdoor enclosures in cold climates and hot rooftop or industrial cabinet installations.

Q: What data rate does the NPD-6001-IBT support?

A: It supports 10/100/1000 Mbps (Gigabit) data pass-through via a shielded RJ-45 connector compatible with EIA 568A and 568B wiring standards.

Q: What safety and emissions certifications does the NPD-6001-IBT carry?

A: The NPD-6001-IBT is certified to UL508 (industrial control equipment), UL/EN/IEC 60950-1 Ed. 2 (IT equipment safety), FCC Part 15 Class A, EN 55032 Class A, and EN 55024. It is also RoHS, WEEE, and CE compliant.

Marty Allison
Marty Allison

The spec that stands out on the NPD-6001-IBT isn't the 60W output — it's the 20–60 VDC input range paired with a -40°C to 75°C operating envelope. Most PoE injectors tie you to an AC source or a narrow DC window; this one lets you wire directly off a 24V industrial bus, a 48V telecom shelf, or a 60V solar system without a DC-DC converter in the chain. That combination genuinely expands where you can place high-wattage PoE devices.

Technical Highlights:

  • 60W Guaranteed Output: Not 'up to' 60W — guaranteed. At 55 VDC on the output pin pair, a Class 5 PTZ or multi-sensor unit gets the full budget every time, not derated by input sag.
  • 170,000h MTBF at 25°C: Nearly 20 years mean time between failures. For remote-tower or difficult-access installs where a service call costs $500+, specifying a unit with this MTBF is a defensible lifecycle decision.
  • 32 BTU/h Heat Loss at Full Load: Running a 60W injector that dumps only 32 BTU/h at 60 VDC input means thermal budget in a sealed enclosure stays manageable. No forced air, no oversized enclosure to hit thermal derate thresholds.

Deployment Considerations:

  • Verify that your powered device supports 802.3bt Type 3 four-pair power delivery — some legacy cameras and access control readers only accept two-pair (802.3af/at) and will not negotiate correctly with a Type 3 PSE.
  • The 4A maximum input current draw at the low end of the input range (20 VDC) means your DC source must be rated for at least 80W continuous at that voltage — a common oversight when drawing from a small battery-backed panel with multiple loads.

This unit earns its place on remote surveillance towers, solar-powered gate cameras, and industrial perimeter installs where the power source is DC-native and the ambient temperature range rules out consumer-grade alternatives. It's a deliberate infrastructure choice, not a substitute for a standard midspan.

Specifications
Dimensions H W D mm: 111 mm x 35 mm x 78 mm
Dimensions H W D in: 4.37 in x 1.38 in x 3.07 in
Weight g: 373 g
Weight lb: 0.82 lb
Input Current A: 4 A
Maximum Heat Loss BTU/h: 32 BTU/h at 60 VDC
Number Of Ports: 1
Data Rates Mbps: 10/100/1000 Mbps
Connectors: Shielded RJ-45, EIA 568A, 568B
Mtbf: 170,000 h at 25 ºC
Operating Temperature C: -40 °C – 75 °C
Operating Temperature F: -40 °F – 167 °F
Storage Temperature C: -40 °C – 85 °C
Storage Temperature F: -40 °F – 185 °F
PoE Input: IEEE 802.3bt type 3 compliant
PoE Output Pin Assignment Polarity: 1/2 (-), 3/6 (+), 4/5 (+), 7/8 (-)
PoE Output Power Voltage VDC: 55 VDC
PoE Output User Port Power W: 60 W (guaranteed)
Input Voltage VDC: 20 VDC – 60 VDC
Regulatory Compliance: IEEE 802.3bt (PoE), RoHS compliant, WEEE compliant, CE
Electromagnetic Emission Immunity: FCC Part 15, Class A, EN 55032 Class A, EN 55024
Safety: UL508, UL/EN/IEC 60950-1 (ed. 2)
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources