Panduit NK Modular Patch Panel Angled 48PT 2 RU
48-port angled flush-mount modular patch panel from the Panduit NetKey line built for structured copper cabling installations in standard 19-inch
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit CP48BLY is a 48-port, 2-rack-unit patch panel from the Pan-Net® line, built entirely from stainless steel and designed to accept up to 48 Mini-Com™ shielded keystone modules. If you're terminating a shielded structured-cabling run — whether copper Cat6A, shielded Cat5e, or specialty media — this panel gives you a clean, grounded, rack-native termination point without the flex and rattle you get from cheaper plastic-chassis alternatives.
Structured-cabling termination panels look simple on spec sheets, but the details determine whether a rack stays organized and maintainable for a decade or turns into a re-punch nightmare at year two. The CP48BLY addresses that with a flat, low-profile stainless steel chassis that occupies exactly 2RU (88.13 mm / 3.47 in) in a standard 19-inch rack — and also mounts in 23-inch racks, which matters in older telco-style enclosures and some industrial control cabinets where 23-inch rails are still common.
Capacity is 48 ports in a 2RU footprint, which keeps density reasonable without jamming cables into an unworkable bundle. Each port position accepts any Mini-Com™ shielded module, so the panel itself is media-agnostic — copper Cat6A, fiber, coax, or specialty inserts all drop in without swapping the panel. That modularity is the real operational advantage: when a single port type changes in a zone, you swap a module, not the panel.
The CP48BLY integrates directly into any standard modular patch panel infrastructure using Mini-Com™ shielded keystone inserts. Port count and 2RU height make it a natural fit alongside managed PoE switches in IDF closets — 48 ports matches a common 48-port switch chassis, keeping patch-to-switch runs clean and one-to-one. The 19-inch mounting width (482.6 mm) fits all standard four-post and two-post EIA racks; the 23-inch compatibility extends reach to legacy telco frames.
For cable management, pair this panel with a 1U or 2U horizontal cable manager above and below to keep patch cord routing orderly at full 48-port density. Without dedicated cable management on a fully-loaded panel, cord weight and routing friction will eventually stress individual module terminations. Review a structured cabling planning guide if you're sizing cable managers and patch cord lengths for a new IDF build-out.
Competitor cross-references for this panel include: 1933079-1, 1933322-2, AX103115, CPP-SDDM-SL-1U-48, CPP-SDDM-SL-2U-48, and HFTP-HD6B-2U-48. If you're replacing one of those models, verify that your existing keystone modules are Mini-Com™ compatible before ordering — the panel accepts Panduit Mini-Com™ modules specifically.
Q: What type of modules does the CP48BLY accept?
A: The CP48BLY accepts up to 48 Panduit Mini-Com™ shielded keystone modules. The panel itself does not include modules — they are purchased separately based on your port type (copper Cat6A, fiber, coax, etc.).
Q: Does the CP48BLY fit in a 23-inch rack?
A: Yes. The CP48BLY mounts in both standard 19-inch (482.6 mm) EIA racks and 23-inch telco-style frames, making it compatible with legacy IDF enclosures that predate 19-inch standardization.
Q: Does the CP48BLY support shielded cabling installations?
A: Yes. The panel is specifically designed to accept Mini-Com™ shielded keystone modules and includes integrated grounding terminals to complete the shield drain path from cable through the panel to rack ground — a requirement for properly terminated shielded (S/FTP or F/UTP) runs.
Q: How much rack space does the CP48BLY occupy?
A: The CP48BLY occupies 2 rack units (2RU), with an overall height of 88.13 mm (3.47 in). Plan for at least one additional 1U slot above and below for horizontal cable management when running at full 48-port density.
Q: Are modules or patch cords included with the CP48BLY?
A: No. The package contains the patch panel chassis only (quantity 1). Mini-Com™ keystone modules and patch cords are sold separately. Verify module compatibility with your cabling category and shielding type before ordering.
Q: What are the cross-reference part numbers for the CP48BLY?
A: Verified competitor cross-references include: 1933079-1, 1933322-2, AX103115, CPP-SDDM-SL-1U-48, CPP-SDDM-SL-2U-48, and HFTP-HD6B-2U-48. Confirm dimensional and module compatibility before substituting.

The CP48BLY is the panel I reach for when a shielded copper run needs a proper rack-native home. The stainless steel chassis and built-in grounding terminals are the two specs that separate it from budget plastic panels — in a shielded Cat6A installation, a panel without a real ground path is a liability, not just a gap in the spec sheet.
Technical Highlights:
Deployment Considerations:
This panel fits best in IDF closets running shielded Cat6A to high-interference environments — manufacturing floors, hospital wings with dense RF, or any zone where unshielded copper performance is unreliable and the shield path needs to be airtight all the way to the panel face.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Panduit products? Shop the full Panduit catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price