Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit D82RDEB Net-Verse 42RU x 800mm Split-Hinged Rear Door

The Panduit D82RDEB is a split-hinged rear door designed specifically for 42RU, 800mm-wide Panduit Net-Verse™ cabinets. If you're finishing out a data center row or a security head-end enclosure and need a rear door that matches the cabinet's footprint exactly, this is the part — dimensionally verified at 78.19 inches (2,253.2mm) tall and 800mm wide to align with the Net-Verse chassis it was built for.

Overview

The D82RDEB ships as a single split-hinged door panel in black, purpose-built for the Net-Verse rack enclosure line. The split-hinge design allows each half of the door to open independently, which is the practical detail that matters most in tight rows — you can open one side for rear cable access or equipment swaps without swinging a full-width panel into an adjacent cabinet or a hot-aisle containment barrier. For integrators managing dense IDF/MDF closets or security equipment rooms where clearance behind the rack is measured in inches, that distinction between a split door and a single-panel door isn't cosmetic.

Key Features

  • Split-Hinge Configuration: Each half of the door opens independently, so rear cable management and equipment servicing don't require full aisle clearance behind the rack — a real advantage in contained hot-aisle deployments or back-to-back cabinet rows where a swing-out full door would be physically blocked.
  • 42RU Height (78.19 in / 2,253.2mm): Matches the full usable height of a standard 42U Net-Verse enclosure. A door that doesn't span the full rack height leaves gaps that disrupt airflow containment and negate the thermal management benefits of the enclosure system.
  • 800mm Width: Dimensionally matched to 800mm-wide Net-Verse cabinets. Ordering a door for a 600mm cabinet when your enclosures are 800mm is a common procurement error — confirm your existing cabinet width before ordering.
  • Black Finish: Matches standard Net-Verse cabinet colorways, keeping the rack row visually consistent. In customer-facing server rooms or security NOCs, an unmatched door color signals a parts mismatch and creates unnecessary questions during audits.
  • RoHS Compliant: Meets Restriction of Hazardous Substances requirements, which matters for enterprise deployments subject to environmental compliance documentation and for projects in jurisdictions where RoHS conformity is a procurement requirement.
  • Net-Verse™ Sub-Brand Fit: Designed and sourced within the Net-Verse product family, so mounting hardware, hinge geometry, and latch mechanisms are engineered to the same tolerances as the cabinet — no field modification, no shimming, no aftermarket bracket work.
  • Single Package Quantity: Ships as one door per order, which keeps procurement straightforward when you need to door out a specific number of enclosures without ordering in bulk.

Integration & Compatibility

The D82RDEB is engineered for Panduit Net-Verse™ cabinets in the 42RU, 800mm-wide configuration. Before ordering, verify both the rack unit count (42RU) and the cabinet width (800mm) of your existing enclosures — Net-Verse cabinets are available in multiple widths (600mm, 700mm, 800mm) and depths, and doors are not interchangeable across width classes. This door will not fit a 600mm or 700mm wide cabinet without forced modification, which would void fit and finish guarantees.

For deployments pairing this door with active thermal management, confirm that any blanking panels and airflow accessories in your cabinet are installed before the rear door is fitted — accessing blanking panel positions through a mounted rear door is inconvenient on split-hinge designs where the inner panel clearance is limited.

This door is catalog number D82RDEB in Panduit's cabinets-thermal-management-racks-enclosures product line. Integrators building out full enclosure packages should verify compatibility with the specific Net-Verse cabinet model number in their BOM; Panduit's product configurator maps rear door SKUs to cabinet chassis SKUs by width and height. If you are specifying a complete rack enclosure solution from scratch, cross-reference the cabinet model's accessory compatibility list to confirm D82RDEB is the correct rear door for your chassis variant.

Frequently Asked Questions

Q: What cabinet dimensions does the D82RDEB fit?

A: The D82RDEB is designed for Panduit Net-Verse cabinets that are 42RU tall and 800mm wide. The door measures 78.19 inches (2,253.2mm) in height and 800mm in width. It is not compatible with 600mm or 700mm wide Net-Verse cabinets.

Q: What does the split-hinge design mean in practice?

A: A split-hinged door is divided into two independently swinging halves. Each half can be opened separately, which allows rear access to the cabinet without requiring the full door-swing clearance that a single-panel rear door demands. This is particularly useful in tight rows or hot-aisle/cold-aisle containment environments where aisle clearance is limited.

Q: Is the D82RDEB RoHS compliant?

A: Yes. The D82RDEB meets RoHS (Restriction of Hazardous Substances) compliance standards, as indicated in the product specifications.

Q: Does this door come with mounting hardware?

A: The product ships as a single door (Package Quantity: 1). For specific hardware included in the package, consult the Panduit Net-Verse product documentation or contact Panduit directly to confirm what mounting hardware is provided with the D82RDEB.

Q: Can the D82RDEB be used on non-Panduit cabinets?

A: The D82RDEB is engineered specifically for the Panduit Net-Verse cabinet line at 42RU x 800mm. Fitting it to a third-party enclosure would require verification that hinge mounting points, latch positions, and overall dimensions are compatible — something that cannot be confirmed without the third-party cabinet's specifications. Net-Verse accessories are designed to tolerance-match the Net-Verse chassis.

Q: What color is the D82RDEB?

A: The D82RDEB ships in black, consistent with the standard Net-Verse cabinet colorway.

Ted Perry
Ted Perry

The D82RDEB is one of those parts that gets overlooked in BOM reviews until someone shows up on site with a completed 42RU Net-Verse cabinet row and no rear door — at which point the 78.19-inch height and 800mm width become very specific numbers very quickly. The split-hinge mechanism on this door is the spec that actually drives the purchasing decision for dense rows; a single-panel rear door on a 42RU cabinet requires roughly 36 inches of unobstructed swing clearance behind the rack, while the split design cuts that requirement roughly in half per leaf.

Technical Highlights:

  • Split-Hinge Operation: Two independently operable door halves mean you can service rear-mounted patch panels, power strips, or cabling infrastructure on one side of the cabinet without disturbing the other — useful when cables are routed through only one half of the rear opening.
  • Dimensional Precision (78.19 in H × 800mm W): The height matches 42RU Net-Verse cabinet chassis to within manufacturing tolerance. A door that gaps at the top or bottom disrupts containment pressure differentials in hot-aisle deployments, which shows up as elevated inlet temperatures on equipment two or three cabinets away.
  • RoHS Compliance: Relevant for government, education, and EU-destined deployments where hazardous substance restrictions are a documentation requirement at the product level, not just the system level.

Deployment Considerations:

  • Confirm your Net-Verse cabinet's width class before ordering — this door is sized for 800mm cabinets specifically. Net-Verse also ships in 600mm and 700mm widths, and those chassis use different rear door SKUs. Measuring the existing cabinet before procurement is faster than a return.
  • If the rack row is in a hot-aisle containment system, install this rear door as the final step after all cable management, blanking panels, and rear-mounted accessories are in place — working through the split-hinge opening after the door is mounted is inconvenient for anything requiring both hands at the rear of the cabinet.

Best fit: security equipment rooms and IDF closets where Net-Verse 42RU x 800mm cabinets are already deployed and the installation requires a matched rear door that won't compromise airflow containment or require full aisle clearance to open.

Specifications
Sub Brand: Net-Verse™
Color: Black
Height In: 78.19
Height Mm: 2253.2
Width In: 2.6
Width Mm: 800
Product Type: Split-Hinged Door
Carton Qty: 0
Package Qty: 1
Standards: RoHS Compliant
Upc: 61305676644
Cable Category: cabinets-thermal-management-racks-enclosures
Q&A
Reviews
Have Questions?

Panduit 42RU X 800MM Width Split RR Door Blacea

$824.43
$488.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources