APC by Schneider Electric 100KVA PDU - PDPM100F-M
100KVA modular power distribution unit designed for 208V systems requiring robust, stand-alone power management
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric SUG5100A90UL is a 100 kVA (90,000 W) three-phase, double-conversion online UPS in tower form factor — built for data centers, industrial facilities, and large commercial installations where a power event cannot be tolerated for even a fraction of a second. Part of the MGE Galaxy 5000 platform, this unit accepts a wide input voltage range (408–600 V) on a three-phase supply and delivers a regulated 480 V to 600 V output, making it well-suited for North American facilities running 480 V distribution. All output connections are via hardwired terminal blocks — there are no NEMA outlet strips at this power class. If you are sizing a critical infrastructure power chain for a large network operations center, a manufacturing floor, or a campus data room, this is the scale of UPS the application demands.
Explore the full APC by Schneider Electric power portfolio for complementary products across this platform family.
The SUG5100A90UL integrates into three-phase 480 V distribution systems via hardwired terminal input and output connections — no plug-and-play connectivity. Installation requires a licensed electrician and coordination with the facility's electrical infrastructure. The unit supports three-phase input and output (3-phase in, 3-phase out), so single-phase load banks require downstream distribution panels or PDUs to split phases. An network management card or compatible SNMP/Modbus interface (consult APC's compatibility matrix for this platform) enables remote monitoring and integration with DCIM or BMS platforms. For facilities requiring structured UPS accessories and battery cabinets, the external battery architecture accommodates up to 4 battery strings for extended runtime.
Q: What input voltage does the SUG5100A90UL require?
A: The SUG5100A90UL accepts three-phase input from 408 V to 600 V at 45–65 Hz. It is designed for North American 480 V three-phase distribution systems but tolerates the full range within that window.
Q: Does the SUG5100A90UL include batteries?
A: No. The battery type is listed as external, and the unit supports up to 4 external battery cabinets. Runtime depends on how many battery strings are connected and the actual load — batteries and runtime extension cabinets are purchased separately.
Q: What certifications does the SUG5100A90UL carry?
A: The SUG5100A90UL is certified to UL 1778 (UPS equipment standard) and UL 924 (emergency lighting equipment). Both are confirmed for this SKU from the source documentation.
Q: What are the physical dimensions of the SUG5100A90UL?
A: The unit is 5,646 mm wide × 813 mm deep × 1,900 mm tall and weighs 8,974.5 kg. This is a very large, heavy installation requiring professional rigging, structural floor load assessment, and coordinated delivery logistics well in advance of installation.
Q: What output connections does the SUG5100A90UL provide?
A: All output connections are hardwired terminal blocks — there are zero NEMA AC outlets. Downstream load distribution requires a compatible three-phase PDU or distribution panel wired directly to the output terminals.
Q: What is the noise level of the SUG5100A90UL?
A: The unit operates at 63 dB under normal conditions. Plan accordingly if the equipment room is adjacent to occupied office areas — acoustic isolation or distance may be warranted.

The SUG5100A90UL is one of those UPS platforms where the physical installation planning is as important as the electrical design — at 8,974.5 kg and 5,646 mm wide, this is not a unit you drop into a standard equipment room without a structural engineer reviewing floor load capacity and a rigging crew coordinating the move-in. The double-conversion topology means zero transfer time to battery, which is the right answer for any load that can't tolerate even a half-cycle interruption, but the operational tradeoff is heat: at 92.9% efficiency, roughly 6,500 W is dissipated as heat at full load, which needs to be accounted for in the room's cooling capacity budget.
Technical Highlights:
Deployment Considerations:
The SUG5100A90UL is the right specification for a greenfield data center or large network operations center buildout at the 100 kVA tier where three-phase 480 V distribution is already in place and the load profile includes server infrastructure that cannot tolerate any transfer gap. It is not the right pick for a small server room, a single-phase application, or any installation without professional electrical and rigging resources on-site.