Panduit 47FT OM4 24-FB ICT POL B OPT IL - FRZUP77Y002F047
47-foot, OM4, 24-fiber interconnect (ICT) optical fiber cable
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit FRZUP77Y002F029 is a 29 ft OM4 multimode fiber trunk assembly built for enterprise data centers and structured cabling rooms where optical margin, polarity discipline, and installation consistency are non-negotiable. Fitted with 24-fiber PanMPO female connectors on both ends in a polarity B configuration, it targets high-density interconnect and cross-connect pathways where a mis-spec'd cable creates rework costs that far exceed the cable's price.
High-density multimode fiber backbones live and die by three variables: connector consistency, polarity scheme, and insertion loss. The FRZUP77Y002F029 addresses all three. The PanMPO female connectors lock into Panduit's structured fiber ecosystem with consistent endface geometry; polarity B is the standard mapping for straight-through MPO-to-MPO links in duplex-converted breakout applications; and the optimized insertion loss construction means you're not burning optical budget at the connector interface. The 29 ft cut is purpose-built for compact rack-to-rack and equipment-to-equipment spans inside a single data hall or wiring closet — not a general-purpose roll-cut, but an assembly specified for a defined run.
The FRZUP77Y002F029 is designed to integrate directly into Panduit's Panduit fiber infrastructure ecosystem — specifically QuickNet cassette modules, PanMPO adapter panels, and the broader fiber optic cable assemblies line. The 24-fiber PanMPO female interface mates with standard MPO-12 and MPO-24 adapter plates, making it interoperable with third-party cassette systems that use industry-standard MPO pin-and-socket geometry. Confirm guide-pin configuration on mating hardware before deployment: female-to-female requires a male-pinned adapter or cassette on the far side.
For data center planners using structured cabling systems, this assembly is a direct fit for MDA-to-HDA backbone links and for equipment-side interconnects feeding 40G/100G SR4 transceivers. Pair it with the appropriate Panduit breakout cassette for LC duplex fan-out, or use it as a direct MPO-to-MPO trunk where the active equipment supports MPO interfaces natively. If you're planning PoE infrastructure alongside fiber runs, see the PoE switch category for compatible distribution hardware.
Q: What polarity scheme does the FRZUP77Y002F029 use, and when is it the right choice?
A: The FRZUP77Y002F029 uses polarity B (straight-through mapping). This is the correct choice for direct MPO-to-MPO trunk links and for installations where duplex transceiver breakout is handled at the cassette level. If your cassettes flip polarity internally (as most Panduit QuickNet cassettes do), polarity B on the trunk is the standard pairing. Verify your cassette polarity type before ordering to avoid a silent link-down at commissioning.
Q: Can the FRZUP77Y002F029 be used in air-handling spaces without conduit?
A: Yes. The plenum-rated (CMP) jacket satisfies NEC Article 770 requirements for cables installed in air-handling spaces — above drop ceilings, in raised floor plenums, and in open-ceiling data centers. No conduit is required in a plenum-rated pathway when using a CMP-rated assembly.
Q: Does the female PanMPO connector require guide pins in the mating adapter?
A: Yes. Female (unfeatured) MPO connectors do not carry guide pins — the mating side must supply them. In standard Panduit cassette and adapter panel configurations, the cassette or adapter plate provides the male-pinned (featured) side. Confirm pin configuration on all mating hardware before installation; a female-to-female mating without an intervening pinned adapter will result in a misaligned connection.
Q: What fiber types and speeds does OM4 support at 29 feet?
A: OM4 multimode supports 100G (100GBASE-SR4) at up to 150m and 400G at up to 150m in appropriate multi-lane configurations. At 29 ft — well under 10m — this cable is comfortably within the optical budget for any current short-reach transceiver standard including 10G, 25G, 40G, 100G, and 400G SR applications. OM4 is also backward-compatible with OM3 transceivers.
Q: How does the aqua jacket help in mixed-fiber environments?
A: Aqua is the TIA-598 standard color for OM3 and OM4 multimode fiber, distinguishing it from OS2 single-mode (yellow) and OM1/OM2 (orange). In a data center running both single-mode long-haul and multimode short-reach infrastructure, aqua allows technicians to visually confirm fiber type without a tester — reducing cross-fiber mating errors during moves, adds, and changes.
Q: Is the FRZUP77Y002F029 a field-terminatable cable or a factory-assembled product?
A: This is a factory pre-terminated assembly. The PanMPO connectors are installed and tested at the factory, eliminating on-site polishing, epoxy, and insertion loss variation from field termination. The 29 ft length is a fixed specification — this is not a bulk cable cut to length.

The spec I always confirm first on a trunk assembly is polarity — and the FRZUP77Y002F029 ships polarity B, which is the straight-through mapping that pairs correctly with most commercial cassette systems that handle the Tx/Rx flip internally. At 29 ft, you're looking at an intra-row or short cross-connect span where every connection in the channel contributes to your insertion loss budget; the optimized loss construction on this assembly means you're starting the math from a tighter baseline than a generic MPO trunk.
Technical Highlights:
Deployment Considerations:
This assembly is the right specification for a dense OM4 backbone in a single-hall data center or a colocation cage where the 29 ft span matches the actual rack-to-rack distance and plenum-path routing is required — particularly in environments standardizing on Panduit's QuickNet cassette infrastructure for consistent channel loss performance across multiple interconnect tiers.