Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRZUP77Y002F029 29ft OM4 24-Fiber PanMPO Plenum Trunk Cable

The Panduit FRZUP77Y002F029 is a 29 ft OM4 multimode fiber trunk assembly built for enterprise data centers and structured cabling rooms where optical margin, polarity discipline, and installation consistency are non-negotiable. Fitted with 24-fiber PanMPO female connectors on both ends in a polarity B configuration, it targets high-density interconnect and cross-connect pathways where a mis-spec'd cable creates rework costs that far exceed the cable's price.

Overview

High-density multimode fiber backbones live and die by three variables: connector consistency, polarity scheme, and insertion loss. The FRZUP77Y002F029 addresses all three. The PanMPO female connectors lock into Panduit's structured fiber ecosystem with consistent endface geometry; polarity B is the standard mapping for straight-through MPO-to-MPO links in duplex-converted breakout applications; and the optimized insertion loss construction means you're not burning optical budget at the connector interface. The 29 ft cut is purpose-built for compact rack-to-rack and equipment-to-equipment spans inside a single data hall or wiring closet — not a general-purpose roll-cut, but an assembly specified for a defined run.

Key Features

  • OM4 Multimode Fiber: OM4 supports 400G at up to 150m and 100G at up to 150m in duplex applications — at a 29 ft intra-rack or cross-connect distance, you're well inside the margin envelope for any current short-reach transceiver. If you're running SR4 or SR8 optics, OM4 is the baseline the spec requires.
  • 24-Fiber PanMPO Female Connectors: A single 24-fiber MPO connection replaces 12 duplex LC pairs — critical when you're managing cable density in a fully loaded patch cabinet. Female (unfeatured) connectors on both ends are the correct choice when the mating cassette or adapter plate provides the guide pins, which is standard in Panduit's QuickNet ecosystem.
  • Polarity B Configuration: Polarity B (straight-through) is the right call for direct MPO-to-MPO interconnects and for duplex transceiver breakout when the cassette handles the pair flip. Specifying the wrong polarity here doesn't fail gracefully — it produces a silent link-down that takes time to debug. Confirming B before ordering is worth the 30 seconds.
  • Optimized Insertion Loss Construction: Tighter insertion loss at the connector means more optical power arrives at the receiver — which matters when you're cascading multiple connections (trunk + cassette + patch cord) inside a structured channel. Every fraction of a dB saved at the trunk connector directly extends the usable channel budget.
  • Plenum-Rated Jacket: The plenum rating (CMP) satisfies NEC requirements for cables run in air-handling spaces — above drop ceilings, in raised floor plenums, and in open-ceiling data centers with active HVAC. Installing a riser-rated (CMR) cable in a plenum path is a code violation; this assembly eliminates that risk without requiring a conduit workaround.
  • Aqua Jacket Color: The aqua jacket is the industry-standard visual identifier for OM3 and OM4 multimode fiber. In a mixed-fiber environment (where OS2 single-mode runs yellow and OM1/OM2 run orange), aqua lets technicians confirm fiber type at a glance — without touching a tester or reading a label under poor lighting conditions.
  • 29 ft Pre-Terminated Length: Pre-terminated assemblies eliminate field termination variables — no polishing, no epoxy, no on-site insertion loss testing. For structured cabling planners, specifying the exact run length also eliminates cable slack management problems that accumulate in high-density patch environments.
  • Breakout-Style Design: The breakout construction fans the 24 fibers into individually accessible strands, supporting both direct MPO-to-MPO trunk use and transition to individual fiber connections at the far end. This is the correct format for high-density backbone extensions and for inter-rack links feeding cassette-based distribution frames.

Integration and Compatibility

The FRZUP77Y002F029 is designed to integrate directly into Panduit's Panduit fiber infrastructure ecosystem — specifically QuickNet cassette modules, PanMPO adapter panels, and the broader fiber optic cable assemblies line. The 24-fiber PanMPO female interface mates with standard MPO-12 and MPO-24 adapter plates, making it interoperable with third-party cassette systems that use industry-standard MPO pin-and-socket geometry. Confirm guide-pin configuration on mating hardware before deployment: female-to-female requires a male-pinned adapter or cassette on the far side.

For data center planners using structured cabling systems, this assembly is a direct fit for MDA-to-HDA backbone links and for equipment-side interconnects feeding 40G/100G SR4 transceivers. Pair it with the appropriate Panduit breakout cassette for LC duplex fan-out, or use it as a direct MPO-to-MPO trunk where the active equipment supports MPO interfaces natively. If you're planning PoE infrastructure alongside fiber runs, see the PoE switch category for compatible distribution hardware.

Frequently Asked Questions

Q: What polarity scheme does the FRZUP77Y002F029 use, and when is it the right choice?

A: The FRZUP77Y002F029 uses polarity B (straight-through mapping). This is the correct choice for direct MPO-to-MPO trunk links and for installations where duplex transceiver breakout is handled at the cassette level. If your cassettes flip polarity internally (as most Panduit QuickNet cassettes do), polarity B on the trunk is the standard pairing. Verify your cassette polarity type before ordering to avoid a silent link-down at commissioning.

Q: Can the FRZUP77Y002F029 be used in air-handling spaces without conduit?

A: Yes. The plenum-rated (CMP) jacket satisfies NEC Article 770 requirements for cables installed in air-handling spaces — above drop ceilings, in raised floor plenums, and in open-ceiling data centers. No conduit is required in a plenum-rated pathway when using a CMP-rated assembly.

Q: Does the female PanMPO connector require guide pins in the mating adapter?

A: Yes. Female (unfeatured) MPO connectors do not carry guide pins — the mating side must supply them. In standard Panduit cassette and adapter panel configurations, the cassette or adapter plate provides the male-pinned (featured) side. Confirm pin configuration on all mating hardware before installation; a female-to-female mating without an intervening pinned adapter will result in a misaligned connection.

Q: What fiber types and speeds does OM4 support at 29 feet?

A: OM4 multimode supports 100G (100GBASE-SR4) at up to 150m and 400G at up to 150m in appropriate multi-lane configurations. At 29 ft — well under 10m — this cable is comfortably within the optical budget for any current short-reach transceiver standard including 10G, 25G, 40G, 100G, and 400G SR applications. OM4 is also backward-compatible with OM3 transceivers.

Q: How does the aqua jacket help in mixed-fiber environments?

A: Aqua is the TIA-598 standard color for OM3 and OM4 multimode fiber, distinguishing it from OS2 single-mode (yellow) and OM1/OM2 (orange). In a data center running both single-mode long-haul and multimode short-reach infrastructure, aqua allows technicians to visually confirm fiber type without a tester — reducing cross-fiber mating errors during moves, adds, and changes.

Q: Is the FRZUP77Y002F029 a field-terminatable cable or a factory-assembled product?

A: This is a factory pre-terminated assembly. The PanMPO connectors are installed and tested at the factory, eliminating on-site polishing, epoxy, and insertion loss variation from field termination. The 29 ft length is a fixed specification — this is not a bulk cable cut to length.

Marty Allison
Marty Allison

The spec I always confirm first on a trunk assembly is polarity — and the FRZUP77Y002F029 ships polarity B, which is the straight-through mapping that pairs correctly with most commercial cassette systems that handle the Tx/Rx flip internally. At 29 ft, you're looking at an intra-row or short cross-connect span where every connection in the channel contributes to your insertion loss budget; the optimized loss construction on this assembly means you're starting the math from a tighter baseline than a generic MPO trunk.

Technical Highlights:

  • 24-Fiber PanMPO Female Interface: Consolidates 12 duplex LC equivalent connections into a single MPO push-pull — essential when you're trying to maintain airflow discipline in a fully-loaded 2-post or 4-post rack environment. Female ends are correct for cassette-terminated pathways where the cassette supplies guide pins.
  • OM4 Multimode at 29 ft: At sub-10m distances, OM4 gives you substantial headroom against any SR transceiver spec in use today — 10G through 400G. The 29 ft factory length eliminates the slack coil problem that accumulates when installers cut bulk cable long and loop the excess inside the cabinet.
  • Plenum (CMP) Jacket Rating: CMP-rated jackets satisfy NEC 770 for open-plenum runs without conduit. In retrofit data center builds where ceiling plenum paths are shared with HVAC, this is not an optional upgrade — it's a code requirement, and a riser cable in that space is a failed inspection.

Deployment Considerations:

  • Confirm the guide-pin configuration on every mating cassette or adapter before pulling cable. Female-to-female MPO interfaces require a pinned adapter in the middle — this is the most common commissioning error on MPO trunk deployments and it produces a connection that seats but doesn't perform.
  • Polarity B is correct for most cassette-based structured systems, but verify against your specific cassette polarity documentation before ordering multiples. A full rack of trunks with the wrong polarity is a full rack of manual re-terminations.

This assembly is the right specification for a dense OM4 backbone in a single-hall data center or a colocation cage where the 29 ft span matches the actual rack-to-rack distance and plenum-path routing is required — particularly in environments standardizing on Panduit's QuickNet cassette infrastructure for consistent channel loss performance across multiple interconnect tiers.

Specifications
Cable Length: 29 ft
Fiber Type: OM4 Multimode
Connector Type: 24-fiber PanMPO Female
Jacket Rating: Plenum
Jacket Color: Aqua
Q&A
Reviews

Panduit 29FT OM4 24-FB ICT POL B OPT IL - FRZUP77Y002F029

$1,417.02
$835.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources