Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRZUP77Y002F027 24-Fiber OM4 PanMPO Plenum Trunk Cable, 27 ft, Polarity B

The FRZUP77Y002F027 is a 27-foot, 24-fiber OM4 multimode trunk assembly built for structured fiber environments where rework cost exceeds cable cost. PanMPO female connectors on both ends, plenum jacket, and Polarity B channel mapping make this a clean-install option for fiber optic trunk assemblies in enterprise and campus distribution frames. If you're spec'ing a dense switch-to-switch backbone or a data center inter-row link and need a ready-terminated, code-compliant run, this assembly addresses all three requirements in a single SKU.

Overview

High-fiber-count trunk assemblies like this one exist to solve a routing problem: running 24 individual patch cords between panels is messy, wastes rack space, and creates a maintenance headache. The FRZUP77Y002F027 consolidates 24 fibers into a single managed run with factory-terminated connectors — meaning your insertion loss numbers are consistent and repeatable from day one. The 27-foot length fits the typical rack-to-rack or row-to-row span in enterprise switching rooms and campus network closets without requiring a custom order. For the broader Panduit structured cabling line, this assembly fits within the PanNet fiber infrastructure ecosystem alongside cassettes, enclosures, and patch cords.

Key Features

  • OM4 50/125 µm Multimode Fiber: OM4 supports 40G and 100G Ethernet over short reaches — typically up to 150m for 100G — making this the right fiber grade for inter-switch and spine-to-leaf links that need headroom for future speed upgrades without re-pulling cable.
  • 24-Fiber Breakout Construction: Twenty-four fibers in one managed trunk replace what would otherwise be 12 duplex patch cords, cutting down on cable congestion at the panel face and simplifying moves-adds-changes. Denser fiber count per run means fewer trunks to manage across high-port-count switch stacks.
  • PanMPO Female Connectors on Both Ends: Factory-terminated PanMPO female connectors eliminate field polishing and the consistency problems that come with on-site termination. Both ends match, so you connect directly into PanMPO-compatible cassettes or modules without needing gender changers or hybrid adapters.
  • Polarity B Configuration: Polarity B preserves correct channel mapping in structured cabling designs using the opposite-end-swap method. If your cassettes and modules are spec'd for Polarity B, this trunk drops in without requiring polarity correction adapters — one less thing to troubleshoot during commissioning.
  • Plenum (CMP) Jacket: The plenum-rated jacket meets fire code requirements for installation in air-handling spaces — ceiling plenums, raised-floor data centers with open return-air paths, and inter-floor conduit runs where non-plenum cable isn't permitted. Skipping the jacket spec here is where installations get flagged during inspection.
  • Optimized Insertion Loss Design: The assembly is engineered for controlled insertion loss, which matters in dense multimode links where every interconnect in the path consumes a portion of the optical budget. Tighter loss numbers mean more headroom for additional connections or longer aggregate spans within the same link budget.
  • 27-Foot Fixed Length: At 27 feet, this trunk is sized for cross-row or adjacent-rack runs in typical enterprise switching environments. A pre-terminated fixed length eliminates the slack management problems that come with oversized trunk assemblies while keeping routing clean in cable managers.

Integration & Compatibility

The FRZUP77Y002F027 is designed for use with PanMPO-compatible cassettes, enclosures, and fiber distribution modules. It integrates into Panduit's PanNet fiber infrastructure but will also mate with any standard MPO ecosystem product that accepts female MPO connectors, provided polarity alignment is confirmed before installation. Verify that your cassettes and MPO modules are specified for Polarity B before ordering — mixing polarity types without correction adapters will result in crossed transmit/receive pairs. This trunk is appropriate for high-density switch interconnects, structured fiber patching in data center distribution areas, and short-reach backbone links in campus network rooms where plenum compliance is required. For planning trunk count and cassette configuration, reference a structured fiber planning guide to ensure channel mapping, polarity, and insertion loss budget are validated before procurement.

Frequently Asked Questions

Q: What connector type does the FRZUP77Y002F027 use on both ends?

A: Both ends use PanMPO female connectors. This is a female-to-female trunk assembly designed to connect into PanMPO-compatible cassettes or modules at each panel location.

Q: What polarity type is this cable, and does it matter for my installation?

A: This assembly is Polarity B. Polarity determines how fiber channels map from one end of the trunk to the other. You must confirm your cassettes and distribution modules are specified for Polarity B — installing a Polarity B trunk into a Polarity A system will cross your transmit and receive pairs and the link will not come up without correction adapters.

Q: Is the FRZUP77Y002F027 suitable for installation in air-handling ceiling spaces?

A: Yes. The plenum (CMP-rated) jacket makes it compliant for installation in air-handling spaces. If your run passes through a ceiling plenum or an open return-air path, plenum-rated cable is required by code in most jurisdictions — this assembly satisfies that requirement.

Q: What fiber grade is this, and what speeds does OM4 support?

A: This is OM4 multimode fiber with a 50/125 µm core-to-cladding ratio. OM4 is rated for 10G, 40G, and 100G Ethernet over appropriate distances. For 100G links, OM4 supports reaches up to 150 meters, making it suitable for intra-building and campus backbone applications.

Q: Can I use this trunk with non-Panduit MPO equipment?

A: The PanMPO female connectors are physically compatible with standard MPO ecosystems that accept female MPO connectors. Confirm polarity alignment and insertion loss budget with your specific equipment before installation — compatibility depends on your cassette and module specifications, not just the connector type.

Q: Why does insertion loss matter for this type of assembly?

A: Every optical connector in a fiber link consumes part of the transceiver's power budget. In dense multimode environments with multiple interconnects in series — trunk, cassette, patch cord — optimized insertion loss on each component preserves more of that budget for the actual link span. Assemblies with uncontrolled insertion loss are the leading cause of marginal links that test near the limit and fail intermittently under temperature variation.

Jerry Tildsen
Jerry Tildsen

The FRZUP77Y002F027 is a straightforward spec decision once you know your polarity scheme — 24 fibers, female PanMPO on both ends, Polarity B, plenum jacket, 27 feet. Where I see integrators get into trouble with assemblies like this is ordering without confirming polarity B across the entire link from cassette to cassette. One mismatched polarity component and you're chasing a link-down condition that looks like a bad transceiver until you trace it back to the trunk.

Technical Highlights:

  • OM4 50/125 µm Fiber: Gives you 100G capability to 150m — covers virtually any intra-building backbone run without touching single-mode pricing. Future-proofs the infrastructure for 100G/400G migration without re-pulling trunk cable.
  • 24-Fiber Count: Twelve duplex channels in a single managed assembly. In a 48-port switch environment, two of these trunks handle the full uplink capacity of a distribution row — versus 24 individual duplex patch cords that would fill a cable manager completely.
  • Optimized Insertion Loss: Factory-controlled loss numbers mean you can calculate your end-to-end optical budget with confidence rather than using a worst-case estimate. Particularly relevant in cascaded installations with trunk-cassette-patch cord links in series.

Deployment Considerations:

  • Verify Polarity B is consistent across every component in the link — trunk, cassettes at both ends, and any adapter panels in the path. A single Polarity A cassette in a Polarity B link will invert your transmit/receive mapping silently and the link will not come up.
  • The 27-foot fixed length works well for adjacent-rack or single-row cross-connects. If your rack-to-rack distance is materially shorter, plan for slack management — excess slack in a cable manager can obstruct airflow and create a congestion point in high-density enclosures.

This assembly is the right call for enterprise switching rooms and campus distribution frames where structured fiber patching is the standard, plenum compliance is required, and the cost of a field-terminated failure is higher than the cost of a factory-terminated assembly. Specify it on new installations where the polarity scheme is locked in from the design phase — not as a retrofit into a mixed-polarity existing plant.

Specifications
Fiber Type: OM4
Fiber Count: 24
Connector Type: PanMPO Female
Cable Length: 27 ft
Jacket Type: Plenum
Core Cladding: 50/125 µm
Q&A
Reviews
Have Questions?

Panduit 27FT OM4 24-FB ICT POL B OPT IL - FRZUP77Y002F027

$1,397.22
$827.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources