Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Middle Atlantic RLNK-920R is a 1U rackmount power distribution unit built for AV integrators, security system installers, and IT rack builders who need per-outlet switching control without stepping up to a full managed PDU. At 20 amps on a single NEMA 5-20P circuit, it handles the power distribution demands of a densely loaded equipment rack — NVRs, managed switches, access control panels, and ancillary gear — while giving you the ability to reboot individual devices remotely rather than cycling the entire rack. If you've ever had to physically pull a switch or recorder out of a rack to hard-reset it, the RLNK-920R addresses exactly that problem.
The RLNK-920R is part of Middle Atlantic's RackLink Select PDU line, which integrates with the RackLink control ecosystem for network-based outlet management, energy monitoring, and scheduled switching. In a security integration context, it pairs naturally with rackmount PDUs and power accessories from the same ecosystem, allowing consistent power management across multiple racks on a single platform.
The NEMA 5-20P input is compatible with any standard 20A commercial branch circuit — the same circuit used by most commercial UPS units in the 1–3 kVA range. Pairing the RLNK-920R downstream of a rackmount UPS gives you both ride-through during power events and per-outlet reboot control during normal operations — a combination that covers the two most common field service scenarios: power outages and frozen devices.
For system integrators building out complete rack solutions, the RLNK-920R fits within Middle Atlantic rack enclosures and cabinets without requiring custom mounting hardware. The standard 19-inch rack width (17.36 in / 44.1 cm) mounts in any EIA-310-compliant enclosure.
Note: the RLNK-920R ships for domestic US deployment only and is not available for international orders. Verify your facility's branch circuit is 20A-rated and protected by a NEMA 5-20R receptacle before installation — the 5-20P plug will not seat in a standard 15A (5-15R) outlet. For rack power planning guidance, sizing the branch circuit correctly to 80% of breaker capacity is the starting point for any reliable rack power design.
Q: What type of outlets does the RLNK-920R provide, and how many can I control independently?
A: The RLNK-920R has 9 IEC-type outlets. All 8 controllable outlets can be switched independently, allowing you to reboot or power-cycle individual devices without affecting others in the rack.
Q: What input plug does the RLNK-920R use, and what branch circuit do I need?
A: It uses a NEMA 5-20P plug, which requires a dedicated 20A branch circuit with a NEMA 5-20R receptacle. Standard 15A outlets will not accept this plug. Plan for 80% utilization (16A maximum continuous load) per NEC guidelines.
Q: Does the RLNK-920R include a UPS or battery backup?
A: No. The RLNK-920R provides basic surge protection only — it does not include battery backup. For ride-through during power outages, install it downstream of a compatible rackmount UPS.
Q: How long is the power cord, and will it reach a standard rack room power panel?
A: The cord is 9 ft (2.7 m) long, which reaches from a rack-mounted PDU to most wall-mounted or overhead power panels in standard equipment rooms without extension cords.
Q: Is the RLNK-920R available for international shipment?
A: No. The RLNK-920R is configured for North American power standards (NEMA 5-20P, 120V) and is not available for international orders.
Q: What rack space does the RLNK-920R occupy?
A: At 1.74 inches tall, the RLNK-920R occupies 1U of rack space. Its 9.67-inch depth fits in shallow wall-mount enclosures as well as standard mid-depth rack cabinets.

The spec I come back to on the RLNK-920R is the 8-outlet independent control on a single 20A circuit — that's the operational difference between a managed PDU and a plain power strip, and it's the spec that pays for itself the first time you remotely reboot a frozen access controller at 2 AM without rolling a truck. If you're speccing racks for multi-site security deployments, the RLNK-920R (also searched as RLNK 920R) belongs in any rack where remote power cycling is a service expectation, not a luxury.
Technical Highlights:
Deployment Considerations:
Best fit: multi-device security and AV racks in commercial facilities where remote outlet-level reboot capability is a managed services requirement — specifically any rack that a technician cannot reach within the same business day.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Middle Atlantic products? Shop the full Middle Atlantic catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price