Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: UPX-RLNK-1500R-8
UPC: 656747395642
Condition: New
Write a Review 49% OFF

Middle Atlantic 1500VA 120V UPS Rlnk Outlet Control - UPX-RLNK-1500R-8

Middle Atlantic UPX-RLNK-1500R-8 1500VA Line-Interactive RackLink UPS with Individual Outlet ControlThe Middle Atlantic UPX-RLNK-1500R-8 is a 1500VA /…

$3,789.00 $1,940.99 SAVE $1848
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Middle Atlantic 1500VA 120V UPS Rlnk Outlet Control - UPX-RLNK-1500R-8

$3,789.00
$1,940.99

Overview

SKU: UPX-RLNK-1500R-8
UPC: 656747395642
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Middle Atlantic UPX-RLNK-1500R-8 1500VA Line-Interactive RackLink UPS with Individual Outlet Control

The Middle Atlantic UPX-RLNK-1500R-8 is a 1500VA / 1350W line-interactive rack UPS built specifically for AV, security, and IT rack environments where you need both runtime protection and per-outlet switched control from the network. At 2RU and 16 inches deep, it fits cleanly in shallow telecom and security equipment racks without consuming excessive real estate. The integrated RackLink network card and individual outlet switching make this a managed power distribution solution as much as a UPS — not just a battery backup you forget about until the power fails.

Overview

Line-interactive topology keeps the inverter continuously in the power path, correcting voltage sags and surges without switching to battery — a meaningful difference from standby (offline) UPS designs that only engage the inverter on full outage. In surveillance and access control deployments where brownouts are a regular occurrence, that continuous regulation protects NVRs, controllers, and network switches from the slow damage of undervoltage cycles. The rack UPS category is full of standby units; the UPX-RLNK-1500R-8 sits in a more capable tier. For deeper background on sizing and topology selection, the power planning and UPS sizing guide is worth a read before you commit to a VA rating.

Key Features

  • 1500VA / 1350W Capacity: 1350W of real power handles a fully loaded 2U NVR, a managed PoE switch, and ancillary gear simultaneously. At 90% power factor (1350W / 1500VA), this is a more honest real-world number than VA alone — size your load against watts, not just VA.
  • Line-Interactive Topology with MOV Surge Protection: The inverter actively conditions incoming 120 VAC continuously, absorbing sags, surges, and brownouts before they reach connected equipment. MOV surge protection adds a secondary layer against transient spikes. Combined, this is the architecture you want behind recorders and controllers in buildings with unreliable utility power.
  • 8 Individually Switched NEMA 5-15R Outlets: Each of the eight outlets can be toggled on/off independently via the network interface — useful for forcing a remote reboot of a locked-up NVR or camera encoder without dispatching a technician. At 15A total circuit capacity, plan your load distribution across the eight ports carefully to stay within thermal limits.
  • Integrated RackLink Network Card: Network management is built in — no separate card to purchase or slot. RackLink gives you remote outlet control, UPS status monitoring, scheduled power cycling, and event alerting over your LAN. For security integrators managing distributed rack closets, this eliminates the need for hands-on access just to reboot a device or check battery health.
  • 2RU Rack Form Factor, 16-Inch Depth: At 19 inches wide × 3.46 inches tall × 16 inches deep, the UPX-RLNK-1500R-8 mounts in standard 19-inch racks with a mounting depth range of 22 to 36 inches. The 44.1 lb weight (20 kg) is significant — confirm your rack's weight capacity and use the full 4 mounting points for structural stability.
  • 120 VAC Input / 110-127 VAC Output, NEMA 5-15P Plug: Draws from a standard 15A, 120V circuit — no dedicated outlet or hardwiring required. Output regulation holds between 110 and 127 VAC, protecting connected gear from the voltage excursions that erode capacitors and power supply longevity over time.
  • Operating Temperature 32°–104°F (0°–40°C): The 40°C upper limit is adequate for most conditioned equipment rooms but is a hard constraint — if your rack closet runs warm in summer, verify ambient temperature before installation. Exceeding the operating range degrades battery life and runtime.
  • RoHS and FCC Compliant: The UPX-RLNK-1500R-8 carries FCC (CSA) and RoHS/REACH certifications, confirming it meets North American EMI standards and restricts hazardous materials — relevant for enterprise procurement and green building requirements. Note: TAA compliant is not claimed for this SKU.

Integration and Compatibility

The RackLink network interface communicates over a standard LAN connection, making it compatible with SNMP-based management platforms and building management systems that support network-managed PDU/UPS integration. Individual outlet control is accessible via the RackLink web interface or CLI, supporting integration into automated runbook workflows for remote site management. The Middle Atlantic power and rack product line includes compatible rack enclosures, cable management, and power distribution accessories engineered to work alongside NEXSYS UPS units in structured rack builds. For installations pairing this UPS with managed PoE switches or NVR systems, the 1350W capacity and 8-outlet layout supports a typical mid-size security rack without requiring a second UPS unit. Consider rack accessories such as cable managers and blanking panels to complete the build and maintain proper airflow around the unit.

Frequently Asked Questions

Q: What is the UPS topology of the UPX-RLNK-1500R-8 — is it standby, line-interactive, or online double-conversion?

A: The UPX-RLNK-1500R-8 uses line-interactive topology. This means the inverter is continuously active and regulates voltage in real time, correcting sags and surges without switching to battery. It is not a standby (offline) unit, and it is not double-conversion (online).

Q: Does the UPX-RLNK-1500R-8 include a network management card, or is that a separate purchase?

A: The network card is included — no separate purchase required. The integrated RackLink interface provides network-based outlet control, UPS monitoring, scheduled power cycling, and alerting out of the box.

Q: How many outlets does the UPX-RLNK-1500R-8 have, and can they be controlled individually?

A: It has 8 NEMA 5-15R outlets, and each can be switched on or off independently via the RackLink network interface. This allows remote reboot of individual devices without affecting other connected equipment.

Q: Is the UPX-RLNK-1500R-8 TAA compliant for government procurement?

A: No. The UPX-RLNK-1500R-8 is manufactured in China and is not TAA compliant. It should not be specified for federal government contracts or projects requiring TAA-compliant equipment.

Q: What rack depth is required to install the UPX-RLNK-1500R-8?

A: The unit itself is 16 inches (40.6 cm) deep, and the rack must support a mounting depth between 22 and 36 inches. It occupies 2 rack units (2RU) of vertical space in a standard 19-inch rack.

Q: What is the warranty on the UPX-RLNK-1500R-8?

A: Per manufacturer documentation, the UPX-RLNK-1500R-8 carries a 2-year product warranty and a 3-year battery warranty.

Eden Phillips
Eden Phillips

The UPX-RLNK-1500R-8 is the unit I reach for when a security integrator needs true per-outlet remote switching — not just monitoring — built into a 2RU UPS without a separate network card purchase. The integrated RackLink interface at 1500VA/1350W puts meaningful managed power capability into mid-size security rack builds without requiring a separate managed PDU alongside the UPS.

Technical Highlights:

  • Line-Interactive at 1350W Real Power: The 90% power factor (1350W / 1500VA) means you can actually load this unit close to its rating. I've seen standby UPS units with poor power factors leave integrators short on runtime when they discover the gap between VA and watts under real load.
  • Individual Outlet Switching via RackLink: Each of the 8 NEMA 5-15R outlets can be cycled remotely — critical for NVR and controller reboots at unmanned remote sites. The built-in network card eliminates the $150–200 add-on card cost common on competing platforms.
  • 2-Year Product / 3-Year Battery Warranty: The extended 3-year battery warranty is worth noting — UPS battery replacement is the recurring cost that catches integrators off guard. A 3-year battery warranty provides a meaningful coverage window on that consumable component.

Deployment Considerations:

  • At 44.1 lbs and 16 inches deep, confirm your rack's weight rating and available depth (22–36 inch mounting range) before specifying. The 4 mounting points are all load-bearing at this weight — do not install with fewer than 4.
  • The 40°C (104°F) operating temperature ceiling is a real constraint in poorly ventilated closets. If ambient rack temperatures exceed this in summer months, battery life degrades measurably and runtime calculations become unreliable.

This unit fits cleanly in a commercial security rack build — a 2RU NVR, a 24-port managed PoE switch, and access control hardware — where the combination of line-interactive conditioning, 1350W capacity, and network-managed per-outlet switching eliminates both a separate PDU and the need for on-site visits to reboot locked equipment.

Specifications
Mount Type: Rack
Input Voltage: 120 VAC
Cord Length: 6 ft (1.8 m)
Depth: 16 in (40.6 cm)
Height: 3.46 in (8.8 cm)
Operating Temp: 32° - 104°F (0° - 40°C)
Weight: 44.1 lbs (20 kg)
Rack Units: 2 RU
Shipping Weight: 527 lbs (239 kg)
Output Voltage: 36 VDC
Width: 19 in (48.3 cm)
Country Origin: China
Mounting Points: 4
Plug Type: NEMA 5-15P
Receptacle Type: NEMA 5-15R
Special Features: NEXSYS UPS
Taa Compliant: No
Upc: 656747395642
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources