Panduit XG84522BS00C5 45RU 800mm Network Cabinet
45RU network cabinet engineered for high-density data center and telecommunications deployments where load capacity, thermal management, and
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit CUCFS08B1 is a 10-pack cabinet-to-floor sealing solution engineered for 800mm-wide enclosures in data centers, server rooms, and structured cabling environments where aisle containment integrity directly affects cooling efficiency and energy costs. At 31.49 inches wide and 3.51 inches tall, each seal closes the gap between the cabinet base and the raised floor or slab, blocking bypass airflow that undermines hot/cold aisle containment — one of the most common and most overlooked efficiency leaks in densely populated rows. This is a thermal management accessory that belongs in any serious cabinet and enclosure deployment where airflow discipline matters.
Each unit in the CUCFS08B1 pack is constructed from a PVC/steel composite and finished with a powder-coat in black, which means it handles the mechanical stress of floor contact without cracking or deforming over years of service. The steel backbone provides structural rigidity under cable loads or accidental contact; the PVC interface layer conforms to minor floor irregularities to maintain a consistent seal line. If you've ever watched a DCIM thermal map light up hot spots along cabinet bases where bypass air is sneaking through unsealed gaps, this is the fix.
The CUCFS08B1 is designed for the Panduit aisle containment and thermal management product line and fits 800mm-wide enclosures — the same footprint targeted by Panduit's Net-Access and SmartZone cabinet families. If your row uses a mix of 600mm and 800mm cabinets, confirm width per cabinet before ordering; 600mm footprints require a different part number. This seal integrates into both hot-aisle and cold-aisle containment configurations, closing the base gap regardless of which end of the airflow path you're sealing. For a complete data center infrastructure deployment, pair floor seals with top and side brush strips to eliminate all bypass airflow paths simultaneously — sealing the base alone while leaving gaps at the top returns only partial containment benefit. Review the aisle containment category for complementary components including overhead containment panels and blanking panels for open rack units.
Q: What cabinet width does the CUCFS08B1 fit?
A: The CUCFS08B1 is sized for 800mm-wide cabinets, with an overall width of 31.49 inches (800mm). It is not interchangeable with 600mm cabinet footprints — verify your enclosure width before ordering.
Q: How many seals are included in one CUCFS08B1 order?
A: Each CUCFS08B1 pack contains 10 floor seals, sufficient to cover a full row of 10 standard 800mm-wide cabinets in one order.
Q: Is the CUCFS08B1 RoHS compliant?
A: Yes. The CUCFS08B1 meets RoHS (Restriction of Hazardous Substances) compliance standards, making it suitable for public sector, enterprise, and LEED-certified facility deployments with environmental materials mandates.
Q: What is the CUCFS08B1 made of?
A: The seal is constructed from a PVC/steel composite with a powder-coated black finish. The steel core provides structural rigidity; the PVC layer provides a compliant floor-contact surface.
Q: What is the height of the CUCFS08B1 floor seal?
A: The seal stands 3.51 inches (89.1mm) tall — enough to bridge raised-floor tile gaps and minor leveling offsets at the cabinet base.
Q: Can the CUCFS08B1 be used in both hot-aisle and cold-aisle containment configurations?
A: Yes. The floor seal closes the gap between the cabinet base and the floor regardless of containment orientation, making it compatible with both hot-aisle and cold-aisle containment setups.

The CUCFS08B1 is the kind of component that doesn't get attention until the thermal audit comes back with hot-spot anomalies along the cabinet base — at which point it becomes urgent. The 89.1mm height and 800mm width are precision fits for standard high-density enclosures, and the PVC/steel composite is the right material call for a floor-contact application where an all-plastic part would eventually deform or crack under repeated thermal cycling and physical contact.
Technical Highlights:
Deployment Considerations:
The CUCFS08B1 is the right call for a new-build or retrofit row of 800mm enclosures in a data center or server room where aisle containment is already in place or being commissioned — specifically where the floor-to-cabinet gap has been identified as a bypass airflow contributor in a thermal audit or CFD model.