Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit PZICEA Active In-Ceiling Zone Cabling Enclosure

The Panduit PZICEA is a 2RU active in-ceiling enclosure designed for zone cabling and fiber-to-zone network infrastructure topologies — the kind of structured horizontal distribution you find in open-ceiling commercial interiors, healthcare facilities, and large office floors where running cable home-run to the MDF is impractical. Built under the Panduit PanZone line, this enclosure keeps active switching and patching gear overhead and out of the way while meeting the plenum fire and smoke requirements those spaces demand.

Key Features

  • 2RU Active Equipment Capacity: Accepts up to 2RU of active gear (switches, PoE injectors) plus 6RU or 8RU for patching — enough room to terminate a full zone's worth of horizontal runs and house the edge switch feeding them, all in one overhead location.
  • 50 lb Verified Load Rating: The confirmed 50 lb structural capacity means you can install a real managed switch plus patch panels without worrying about ceiling grid stress — relevant when you're specifying for T-bar ceilings with standard 15/16" grid systems.
  • Active Thermal Management: Built-in heat dissipation handles high-heat applications — critical when you're running a PoE switch at sustained load inside an enclosed ceiling space where ambient temps can climb. Passive enclosures in similar applications frequently cause switch throttling or premature failure.
  • UL 2043 Plenum Rating: Tested and listed for plenum air-handling spaces per UL 2043, which is the code requirement for any equipment installed in the air return above a suspended ceiling in most US jurisdictions. Skipping this certification creates a code violation and a liability problem on commercial buildouts.
  • UL 1863 Listed: Listed under UL 1863 for communications circuit accessories — confirms the enclosure meets the additional requirements for housing telecom and data termination equipment, not just structural compliance.
  • OSHPD (OPM) Approved: Carries California OSHPD (Office of Statewide Health Planning and Development) seismic approval for use in healthcare facilities — opens this unit for hospital and clinic deployments in California where seismic compliance is mandatory for overhead equipment.
  • RoHS Compliant: Meets RoHS hazardous substance restrictions — required for projects with environmental procurement mandates or EU-destined equipment.
  • Steel Construction, White Finish: 23.5" wide (596.9 mm) by 13.43" tall (341.1 mm) steel body. The white finish integrates cleanly with standard commercial ceiling tile environments and reduces the visual intrusion of an overhead enclosure in occupied spaces.
  • Multiple Cable Entry/Exit Points: Designed with additional cable ingress and egress points to handle higher cable counts — relevant on dense zone distributions where a single port cluster creates a cable management bottleneck.

Integration and Compatibility

The PZICEA is purpose-built for structured cabling zone distribution architectures where fiber or copper backbone terminates at a zone enclosure and horizontal runs fan out to workstations, APs, or IP devices. It accommodates standard 19" rack-mount equipment at 2RU active depth. Pair with Panduit patch panels and compatible zone cabling connectors to build a complete PanZone-compliant distribution point. The plenum and OSHPD ratings make it directly specifiable on healthcare, education, and Class A commercial projects without substitution risk.

Frequently Asked Questions

Q: Is the Panduit PZICEA rated for installation in plenum air-handling spaces?

A: Yes. The PZICEA carries UL 2043 plenum rating and UL 1863 listing, making it code-compliant for installation above suspended ceilings used as air return plenums in commercial construction.

Q: What is the maximum equipment load the PZICEA can support?

A: The PZICEA has a verified structural load capacity of 50 lbs, supporting 2RU of active equipment and 6RU or 8RU of patching gear simultaneously.

Q: Can the PZICEA be used in California hospital or healthcare projects?

A: Yes. The PZICEA holds OSHPD (OPM) approval, which satisfies California's seismic compliance requirement for overhead-mounted equipment in healthcare facilities.

Q: Does the PZICEA include thermal management for active switching equipment?

A: Yes. The enclosure incorporates active thermal management designed to handle high-heat equipment loads — important for preventing switch throttling in enclosed ceiling environments.

Q: What are the physical dimensions of the PZICEA?

A: The PZICEA measures 23.5 inches wide (596.9 mm) by 13.43 inches tall (341.1 mm). It is constructed from steel with a white finish.

Jerry Tildsen
Jerry Tildsen

The PZICEA is the unit I specify when a project needs a compliant zone distribution point above the ceiling and the AHJ is going to inspect for UL 2043 — which on healthcare and Class A commercial is nearly every job. The 50 lb verified load capacity is the spec that matters most at installation time; I've seen integrators try to hang unrated enclosures on standard T-bar grid and end up with a sagging ceiling and a punch-list item that kills the closeout.

Technical Highlights:

  • UL 2043 Plenum + UL 1863: Dual-listed — UL 2043 covers the plenum fire/smoke requirement; UL 1863 covers the communications circuit accessory classification. Both are needed on a commercial submittal, and having them on a single SKU simplifies the approval package.
  • 2RU Active + 6–8RU Patching: The mixed active/patching capacity in one ceiling-mount footprint means you can terminate horizontal runs AND house the zone switch at the same overhead location — reduces the number of distribution points and the amount of exposed conduit needed to connect them.
  • Active Thermal Management: Most passive in-ceiling enclosures throttle a loaded PoE switch within a few hours in summer. The built-in thermal management in the PZICEA is the reason to choose it over a passive box when you're running 802.3at or 802.3bt class switches at sustained load.

Deployment Considerations:

  • OSHPD (OPM) approval means this unit can go on California healthcare submittals without a seismic equivalency letter — confirm your local AHJ recognizes OPM approval (most California-based inspectors do), but outside California this certification is irrelevant to the approval path.
  • The enclosure ships as a single unit (package quantity 1) — confirm ceiling grid spacing and available knockout positions before ordering; the 23.5" width requires adequate T-bar bay clearance and the installation crew should verify load path to the structural deck, not just the grid wire.

Best-fit deployment: open-plan commercial floors, hospital wing horizontal distribution, or education building zones where plenum compliance is non-negotiable, active switching must live overhead, and the project will face a formal inspection at closeout.

Specifications
Sub Brand: PanZone®
Color: Weiß
Material: Stahl
Height In: 13.43
Height Mm: 341.1
Width In: 23.5
Width Mm: 596.9
Product Type: In Decke integriertes Gehäuse
Carton Qty: 0
Package Qty: 1
Standards: UL 2043 Plenum-bemessen und UL 1863 bemessen, OSPHD (OPM), RoHS-konform
Upc: 07498300908
Cable Category: cabinets-thermal-management-racks-enclosures
Q&A
Reviews
Have Questions?

Panduit Zone Cabling Active In-ceiling Encl

$4,841.02
$2,823.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources