Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL48WMCMS-W-SC-00-CM 25U Wall-Mount Network Cabinet

Overview

The Vertiv GL48WMCMS-W-SC-00-CM is a 48-inch (25U) wall-mount cabinet finished in Winter White — a practical choice for open-office IT closets, classroom AV installations, and retail back-of-house environments where a standard black enclosure reads as an eyesore. This unit ships in the W-SC-00-CM configuration: Winter White color, SEAL Combo access control, no supplemental airflow (fan-ready but fan not included in this SKU), and integrated cable management. If you're evaluating the Vertiv Geist wall-mount line or the broader Vertiv infrastructure catalog, the GL48WMCMS-W-SC-00-CM (often searched as GL48WMCMS W SC 00 CM) represents the mid-tier cabinet in a family that scales from 12U to 25U across three height options.

Wall-mount enclosures in the network cabinet category often get underspecified on paper because the real differentiators — access control type, door style, cable management depth, airflow provisions — are buried in the model suffix. This page decodes each of those choices and explains what they mean for your specific install.

Key Features

  • 25U usable depth (48-inch chassis): At 25U, this enclosure handles a real mixed-use load — patch panel, managed PoE switch, small UPS, and a cable modem stack — without the depth penalty of a full-width floor cabinet. Wall-mounting keeps the gear off the floor, which matters in areas with custodial traffic or periodic flooding risk. Size up to the wall-mount cabinet collection if your gear count is growing faster than expected.
  • Winter White color option: The W suffix on GL48WMCMS-W-SC-00-CM indicates Winter White finish. In healthcare corridors, education buildings, and retail floor installations, white cabinets blend into painted drywall and avoid triggering facilities complaints about industrial-looking equipment. If you need the same cabinet in black, the non-W variant is available in the same family.
  • SEAL Combo access control: The SC suffix specifies the SEAL Combo lock — a keypad combination lock that eliminates key management entirely. For multi-tenant buildings or school environments where IT staff turnover is frequent, a combinator lock lets you rotate the code without cutting new keys. The SEAL Electronic (SE) variant adds electronic audit-trail capability if compliance logging is a requirement.
  • Door options — Plexi, Mesh, or Solid: This family supports three door styles. Plexi doors let you visually confirm indicator light status without opening the cabinet — useful in low-traffic areas where you want passive monitoring. Mesh doors maximize passive convection airflow and are the right call when fan units aren't installed. Solid doors provide the cleanest visual appearance but will require the fan accessory if heat-generating gear is inside.
  • Fan-ready airflow provisions: The 00 in the model string indicates this unit ships without fans installed. The chassis supports fan kit additions, so you can start fan-free if your equipment load is light (passive cooling via mesh door), then add fans when you add higher-density switching or UPS hardware. Don't install solid-door + zero fans with anything generating more than modest thermal load.
  • Cable Bar management (CM suffix): The CM configuration includes a cable bar for horizontal cable dressing inside the cabinet. Compared to the None variant, cable bar gives you a defined path for patch cords and prevents bundle sag across active gear. If your runs are dense enough to need vertical cable management on both rails, verify the accessory compatibility — this model ships with the basic horizontal bar, not a full vertical manager.
  • Multiple height options in the same family: If 25U is more than you need, the same cabinet line is available at 12U (24-inch chassis) and 19U (36-inch chassis). All three heights share the same access control, door, and cable management suffix system, so scaling down means specifying the shorter variant — not a different product family.

Integration and Compatibility

The GL48WMCMS-W-SC-00-CM is designed for standard 19-inch EIA rack equipment. Most 1U and 2U managed switches, patch panels, and wall-plate consolidation points mount directly. Pair this enclosure with a compatible PoE switch for a clean IDF closet build — the cable bar keeps patch cord runs organized between the switch and panel. If you're deploying security infrastructure, this cabinet suits a small NVR, a PoE switch, and a patch panel stack in a single neat enclosure, particularly in locations where a full floor-standing rack would be disproportionate. For power delivery inside the cabinet, a horizontal PDU or small UPS fits within the 25U budget — size your UPS rack unit count before finalizing your gear list.

Frequently Asked Questions

Q: What does the model suffix 'W-SC-00-CM' mean on the GL48WMCMS-W-SC-00-CM?

A: Each segment encodes a configuration choice: W = Winter White color, SC = SEAL Combo access control (keypad combination lock), 00 = no fans included, CM = cable bar cable management. Changing any segment selects a different configuration within the same cabinet family.

Q: Can fans be added to the GL48WMCMS-W-SC-00-CM after purchase?

A: Yes. The 00 in the model string means this unit ships without fans, but the chassis is fan-ready. Compatible Vertiv fan kit accessories can be added when your equipment load generates more heat than passive convection handles — typically when dense switching or UPS hardware is installed.

Q: What door styles are available for this cabinet?

A: The GL48WMCMS family supports Plexi (see-through acrylic for passive visual monitoring), Mesh (maximum passive airflow, best for fan-free installs), and Solid (cleanest appearance, requires active cooling for heat-generating equipment). Verify the door suffix in your specific model string to confirm which is installed.

Q: Is the SEAL Combo lock rekeyed or reprogrammed if the code is compromised?

A: SEAL Combo locks use a mechanical keypad combination. The code can be changed without cutting keys, which simplifies access management when staff turns over. If audit-trail logging is required, consider the SEAL Electronic (SE) variant in the same cabinet family instead.

Q: What is the usable rack space in the 48-inch (25U) version of this cabinet?

A: The GL48WMCMS-W-SC-00-CM provides 25U of usable rack space. The same cabinet line also ships in 24-inch (12U) and 36-inch (19U) configurations if a smaller footprint better fits the wall space available.

Q: Is the GL48WMCMS-W-SC-00-CM rated for outdoor or environmental use?

A: No environmental or ingress protection rating is specified for this model. It is a commercial-grade indoor enclosure intended for climate-controlled spaces such as IT closets, office environments, classrooms, and retail back-of-house areas.

Marty Allison
Marty Allison

The detail I always flag on a wall-mount cabinet spec sheet is the access control suffix — and on the GL48WMCMS-W-SC-00-CM, the SC designation for SEAL Combo is the right call for most multi-user environments. A mechanical combo lock eliminates the key-cutting cycle when IT staff changes, which is a recurring friction point in school districts and multi-tenant office builds where I see this cabinet installed most frequently.

Technical Highlights:

  • 25U capacity (48-inch chassis): Enough vertical space to host a managed PoE switch, 24-port patch panel, small UPS, and a cable consolidation block simultaneously — without the floor footprint of a full-standing rack.
  • Fan-ready, ships without fans (00 config): Passive cooling via mesh door is viable for low-density switch and patch panel installs. Adding a Vertiv fan kit later is straightforward, so you're not paying for active cooling until your heat load justifies it.
  • Winter White finish: Not cosmetic filler — white enclosures in healthcare and education environments reduce facilities pushback on visible IT gear, and in some jurisdictions are part of interior design compliance for public-use spaces.

Deployment Considerations:

  • Confirm wall stud or blocking capacity before mounting a populated 25U cabinet — a full load of switching and UPS gear exceeds what a drywall anchor pattern handles safely. Steel stud or solid blocking is the right substrate.
  • The 00 fan configuration with a solid door is a thermal risk if you're running anything above light patch-and-switch density — either spec the mesh door or plan the fan kit into the initial order, not as an afterthought.

This cabinet is a strong fit for K-12 IDF closets and retail back-of-house IT builds where 25U covers the gear count, the Winter White finish meets aesthetics requirements, and SEAL Combo simplifies access management across a distributed facilities team.

Specifications
Height: 24" (12U)36" (19U)48" (25U)
Color: BlackWinter White
Door: PlexiMeshSolid
Access Control: Swing HandleSEAL ComboSEAL Electronic
Airflow: NoneFan
Cable Management: NoneCable BarClear
freight: 565.40
Q&A
Reviews
Have Questions?

Vertiv WM Premium 25UX24X32 Gray - GL48WMCMS-W-SC-00-CM

$2,572.00
$1,744.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources