Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL48WMCMS-B-SE-00-00 25U Wall-Mount Network Enclosure

Overview

The Vertiv GL48WMCMS-B-SE-00-00 is a 25U (48-inch tall) wall-mount network enclosure built for edge deployments where floor space is unavailable or impractical — IDF closets, remote security equipment rooms, and branch office wiring rooms being the most common fit. This model ships in black with a mesh door and SEAL Electronic access control, pairing physical security with airflow management in a single configurable unit. If you've been searching for this enclosure as GL48WMCMS B SE 00 00, this is the same SKU.

Vertiv's GL-series wall-mount line offers the same enclosure chassis across three heights — 12U (24 inches), 19U (36 inches), and 25U (48 inches) — which matters when you're standardizing on a single cabinet form factor across multiple sites but have varying equipment densities per location. The GL48WMCMS-B-SE-00-00 represents the largest of the three, giving you the runway to mount switches, patch panels, UPS units, and edge compute gear without moving to a floor-standing rack.

Key Features

  • 25U capacity (48-inch height): The largest available in the GL-series wall-mount line, this unit can accommodate more gear than a typical 12U or 19U IDF cabinet without requiring floor footprint. When you're planning for NVR expansion, managed PoE switches, or structured cabling terminations in a confined security room, 25U gives you meaningful headroom.
  • SEAL Electronic access control: This model includes SEAL Electronic locking — a credential-based lock rather than a standard key swing handle. In multi-tenant facilities or any environment where physical access to network gear requires an audit trail, electronic access control eliminates the shared-key problem common to conventional cabinet locks. Note that SEAL Combo is also an available option across the family if you need a PIN-plus-key fallback.
  • Mesh door: The mesh door option on this configuration promotes passive airflow across the full door surface, reducing thermal resistance compared to solid or plexi doors. In dense equipment installs — particularly PoE switches drawing sustained wattage — passive airflow through a mesh front makes a measurable difference in sustained operating temperatures. If you need visual inspection without opening the door, note that a plexi door is available in alternate configurations.
  • Fan airflow option: The GL48WMCMS-B-SE-00-00 is configured with active fan airflow support, which is the right call for edge enclosures housing equipment that runs 24/7 at elevated ambient temperatures. In unconditioned spaces like warehouse equipment rooms or exterior building closets without dedicated HVAC, passive convection alone is often insufficient — active fan units move air directionally through the equipment space.
  • Cable bar management: This configuration includes a cable bar, which provides horizontal strain relief and routing control for patch cables and power cords. In wall-mount installs, cable management discipline is more critical than in floor-standing racks — unconstrained cables can interfere with door closure and airflow paths. A clear cable management option is also available in alternate builds for installers who prefer visibility into cable routing without opening the cabinet.
  • Black finish: The GL48WMCMS-B-SE-00-00 ships in black. The GL-series also offers Winter White as an alternate finish when enclosure aesthetics matter — retail environments, healthcare lobbies, or office areas where standard rack black reads as industrial. Specify during procurement if finish matters for your environment; it's a configuration-level selection, not a field modification.
  • Multi-height family standardization: The 12U (24-inch), 19U (36-inch), and 25U (48-inch) variants share the same mounting footprint pattern and door/lock/airflow option matrix. For MSPs and integrators managing multiple customer sites, standardizing on the GL-series means consistent installation procedures, consistent spare parts, and consistent access control credentials across all three sizes.

Integration and Compatibility

The GL48WMCMS-B-SE-00-00 is a passive enclosure infrastructure product compatible with standard 19-inch rackmount equipment — switches, patch panels, NVRs, UPS units, and edge servers that fall within the 25U depth envelope. The SEAL Electronic locking system is a Vertiv-family access control mechanism; confirm credential management compatibility with your facility access control platform before specifying if centralized lock management is a requirement. The fan and cable bar are factory-installed in this configuration; verify with Vertiv that field upgrade kits exist before ordering a base configuration with intent to add these later.

For deployments integrating this enclosure into a network switch stack or pairing it with UPS and power equipment, confirm the combined equipment weight against the wall-mount load rating for your wall construction type — drywall, concrete, and CMU block have significantly different load capacities. Consult the Vertiv Vertiv enclosure catalog for wall-mount hardware specifications and installation templates. For security integrators mounting NVR appliances and PoE switch infrastructure in this enclosure, the 25U depth accommodates most 1U–2U NVR form factors alongside a managed switch without exceeding the chassis depth envelope.

Frequently Asked Questions

Q: What is the rack unit capacity of the GL48WMCMS-B-SE-00-00?

A: The GL48WMCMS-B-SE-00-00 is the 25U (48-inch tall) configuration in the GL-series wall-mount line. The family also includes 12U (24-inch) and 19U (36-inch) variants if you need a smaller footprint.

Q: What type of access control does the GL48WMCMS-B-SE-00-00 use?

A: This model is configured with SEAL Electronic access control. The GL-series also supports Swing Handle and SEAL Combo configurations in alternate builds, but this specific SKU ships with the electronic lock option.

Q: Does the GL48WMCMS-B-SE-00-00 include active cooling?

A: Yes. This configuration includes fan airflow support. The GL-series offers a no-airflow option in other builds, but the GL48WMCMS-B-SE-00-00 is spec'd with fans — appropriate for 24/7 edge equipment installs in ambient or unconditioned spaces.

Q: What door type is included with the GL48WMCMS-B-SE-00-00?

A: This unit ships with a mesh door, which promotes passive airflow through the door face. Plexiglass and solid door options are available in alternate configurations within the GL-series family.

Q: What color does the GL48WMCMS-B-SE-00-00 come in?

A: Black. A Winter White finish is available as an alternate configuration in the GL-series for environments where aesthetics are a factor.

Q: Does this enclosure include cable management?

A: Yes — the GL48WMCMS-B-SE-00-00 includes a cable bar for horizontal cable routing and strain relief. A clear cable management panel option is available in alternate builds. A no-management option also exists within the family.

Ted Perry
Ted Perry

The GL48WMCMS-B-SE-00-00 is the configuration I'd reach for on a security equipment room build-out where floor space is constrained but you still need a credible 25U of rack capacity — the SEAL Electronic lock is what separates this from a standard swing-handle wall-mount in any environment where physical access to the equipment needs to be controlled and logged rather than just locked.

Technical Highlights:

  • 25U (48-inch) chassis: The largest GL-series wall-mount option gives you room for a managed PoE switch, NVR, patch panel, and a small UPS — the full edge stack — without a floor-standing rack. That's a practical fit in IDF closets where a floor cabinet simply won't fit.
  • SEAL Electronic access control: Credential-based locking on the GL48WMCMS-B-SE-00-00 means no shared physical keys. In multi-tenant or enterprise environments where cabinet access needs to align with user identity, this is the correct option — the swing-handle variant solves nothing for access governance.
  • Mesh door plus fan airflow: The combination of a mesh door and active fan support is the right thermal spec for a densely loaded edge enclosure running 24/7. In an unconditioned wiring closet, solid doors plus passive cooling is a known failure mode — this configuration avoids it.

Deployment Considerations:

  • Wall-mount load rating is a function of your wall substrate — concrete and CMU can typically support the full loaded weight of a 25U enclosure, but standard drywall over wood stud cannot without reinforcement. Confirm the structural load path before mounting, especially in retrofits.
  • The cable bar in this configuration provides routing control, but 25U of gear generates more patch cable volume than most integrators plan for. Size your cable management accordingly before the enclosure is populated — retrofitting management in a loaded wall-mount is difficult.

This unit is a direct fit for IDF-room security deployments in enterprise or multi-site environments where electronic access control, active cooling, and a full 25U equipment capacity are all required in a wall-mount form factor — specifically in spaces where a floor-standing rack is ruled out by room constraints.

Specifications
Height: 24" (12U)36" (19U)48" (25U)
Color: BlackWinter White
Door: PlexiMeshSolid
Access Control: Swing HandleSEAL ComboSEAL Electronic
Airflow: NoneFan
Cable Management: NoneCable BarClear
freight: 565.40
Q&A
Reviews

Vertiv WM Premium 25UX24X32 Gray - GL48WMCMS-B-SE-00-00

$3,222.00
$2,356.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources