Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL36WMCMM-W-SH-AF-CM 19U Wall Mount Network Enclosure with Fan and Cable Management

Overview

The Vertiv GL36WMCMM-W-SH-AF-CM is a commercial-grade 19U wall mount enclosure built for edge network closets, IDF rooms, and distributed AV or security equipment installations where rack space is limited and floor-mounted cabinets are impractical. Configured in Winter White with a swing handle, active fan airflow, and cable management, the GL36WMCMM-W-SH-AF-CM targets deployments where ventilation and cable discipline matter as much as the physical footprint.

Rated to UL2416 and compliant with RoHS II, this enclosure meets the certification baseline required by facilities managers and AV/IT integrators alike — useful when building specifications or customer procurement policies require documented safety and environmental compliance.

Key Features

  • 19U Rack Space in a Wall-Mount Form Factor: 19U of usable space lets you mount a managed PoE switch, patch panel, a small NVR, and ancillary gear — all off the floor. That matters in server rooms without raised flooring, IT closets converted from storage, or retail back-of-house installations where square footage is constrained.
  • Active Fan Airflow (AF Configuration): The integrated fan module moves air through the enclosure continuously, preventing heat buildup around densely populated switch or recorder shelves. Passive venting alone is inadequate once a managed PoE switch and a recording appliance share the same enclosure — the fan configuration directly addresses that scenario.
  • Swing Handle Access: The swing handle (SH) allows single-handed door release and pull-open access without tools — practical during maintenance rounds when both hands are occupied with a laptop or cable tester. Compared to a keyed cam-lock-only door, swing handle access reduces service time on routine visits.
  • Cable Management Included (CM Configuration): Integrated cable management channels keep patch cables, power runs, and signal wiring separated and routed cleanly. Unmanaged cabling in a wall enclosure restricts airflow and turns a 20-minute swap into an hour-long untangle — the built-in management bar prevents that from becoming routine.
  • Winter White Finish: The Winter White color is specified for environments where a gray or black cabinet would visually clash — lobbies, open office spaces, healthcare corridors, or education common areas where the enclosure is visible and aesthetics are part of the installation requirement.
  • UL2416 Listed: UL2416 is the standard for information technology equipment cabinets. Listing under this standard confirms the enclosure has been independently tested for structural integrity and fire-resistance characteristics — a checkbox requirement on many commercial construction and tenant-improvement projects.
  • RoHS II Compliant: RoHS II restricts hazardous substances in electrical and electronic equipment. Compliance is a procurement gate for government, healthcare, and EU-destined installations — it also simplifies disposal at end of life without special-waste handling.
  • Plexi/Mesh/Solid Door Options Available in the GL36WMC Family: While this SKU (GL36WMCMM-W-SH-AF-CM) ships in a specific door configuration, the broader enclosure family supports plexi, mesh, and solid door variants — useful context when specifying for environments with different visibility, security, or airflow requirements across multiple rooms.

Integration and Compatibility

The GL36WMCMM-W-SH-AF-CM uses standard EIA 19-inch rack spacing, making it compatible with any 19U-rated network, AV, or security equipment. It integrates naturally into wall mount enclosure deployments alongside managed PoE switches powering IP cameras or access control readers, small-form-factor NVRs, patch panels, and UPS battery backup units sized for IDF loads. When planning power density, account for the fan draw plus the combined wattage of all installed equipment — the enclosure itself does not include a built-in PDU, so a separately mounted power strip or rack PDU should be part of the bill of materials.

For installations requiring a full network cabinet rather than a wall mount — or where equipment depth exceeds the enclosure's rated depth — consider a floor-standing unit from the Vertiv VR or VX series instead. The GL36WMC family is designed for shallower equipment profiles typical of patch panels, compact switches, and 1U appliances.

Frequently Asked Questions

Q: What standards does the GL36WMCMM-W-SH-AF-CM comply with?

A: The GL36WMCMM-W-SH-AF-CM is UL2416 listed and RoHS II compliant. UL2416 covers information technology equipment cabinets and is required on many commercial construction projects. RoHS II restricts hazardous substances and is a procurement requirement for government, healthcare, and EU-based installations.

Q: Does this enclosure include active cooling, or is it passively ventilated?

A: This SKU includes an active fan (AF configuration), which continuously moves air through the enclosure. For installations with a managed PoE switch and recording appliance sharing the same cabinet, active cooling is strongly recommended over passive venting alone.

Q: What does the swing handle provide that a standard cam lock does not?

A: The swing handle allows tool-free, single-handed door release. This is practical during maintenance visits when a technician is carrying equipment or a laptop — it reduces service time compared to fumbling for a key on a cam-lock door.

Q: Is the Winter White finish standard, or can I order this in gray or black?

A: The GL36WMCMM-W-SH-AF-CM is specifically the Winter White configuration. The GL36WMC family includes gray and black variants under different SKUs — confirm the correct color code when ordering for multi-room deployments to ensure visual consistency.

Q: Does the enclosure ship with cable management hardware?

A: Yes — the CM suffix in the SKU indicates the cable management configuration is included. This provides routed channels for patch cables, power runs, and signal wiring to keep the interior organized and airflow unobstructed.

Q: What equipment depth does this wall mount enclosure support?

A: The GL36WMC family is designed for equipment profiles typical of patch panels, compact switches, and 1U appliances. For deeper equipment (2-post rail gear, full-depth servers, or large UPS units), a floor-standing enclosure from the Vertiv VR or VX series is the appropriate alternative.

Ted Perry
Ted Perry

The GL36WMCMM-W-SH-AF-CM covers a specific gap in the Vertiv wall mount line: the combination of active fan airflow, integrated cable management, and swing handle access in a single 19U Winter White SKU. Most integrators order these for IDF closets and edge security equipment rooms where the cabinet is visible — the Winter White finish is a genuine aesthetic specification, not a cosmetic afterthought, and it matters on healthcare and education projects where facilities managers have color standards.

Technical Highlights:

  • UL2416 Listing: This isn't a self-declared compliance — it's third-party listed, which clears the procurement gate on commercial construction and tenant-improvement projects that require independent safety certification for rack enclosures.
  • Active Fan (AF) Configuration: The fan moves air continuously, not on a thermal trigger. That matters when a compact managed switch and a small NVR are sharing the same 19U space — passive convection stalls under combined load in a sealed wall cabinet.
  • RoHS II Compliance: Relevant for any installation with a government, healthcare, or EU-destined component — it's a documented procurement requirement in those verticals, not just an environmental preference.

Deployment Considerations:

  • Plan your PDU before the enclosure ships. The GL36WMCMM-W-SH-AF-CM does not include a built-in power distribution unit — a separately mounted rack PDU needs to be on the BOM, or you'll be field-improvising power on install day.
  • The swing handle reduces service time but does not replace a locking mechanism for secure-area deployments. If the enclosure is in an unsecured corridor or public-facing space, verify whether the access control configuration (SH vs. SEAL vs. Electronic) matches your physical security policy before ordering.

This enclosure is the right call for an education or healthcare IDF room where the cabinet is wall-mounted in a visible corridor, aesthetics are part of the specification, and the equipment load includes at least one active switching or recording device that generates enough heat to warrant a fan — not just passive patch panels.

Specifications
Dimensions: 24" (12U) 36" (19U) 48" (25U)
Door: Plexi Mesh Solid
Color: Black Winter White
Access Control: Swing Handle SEAL Combo SEAL Electronic Swing Handle ▾
Airflow: None Fan None ▾
Cable Management: None Cable Bar None ▾ Clear
Standards: UL2416, RoHS II
freight: 565.40
Q&A
Reviews
Have Questions?

Vertiv WM Premium 19UX24X32 FAN Gray - GL36WMCMM-W-SH-AF-CM

$2,571.00
$1,743.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources