Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL48WLP-B-SC-00 48U Wall-Mount Network Enclosure

Overview

The Vertiv GL48WLP-B-SC-00 is a wall-mount enclosure from Vertiv's Geist/Liebert line, available in 24U, 36U, and 48U configurations, finished in gray. It's designed for network closets, wiring rooms, and distributed IT deployments where floor space is unavailable but structured cabling and active network gear still need a secure, managed home. GL48WLP-B-SC-00 (often searched as GL48WLP B SC 00) targets environments where access control and cable management are non-negotiable — not an afterthought.

If you're deploying edge compute, telecommunications distribution frames, or branch network infrastructure, explore the broader Vertiv enclosure and power catalog for rack PDUs, UPS systems, and thermal management that complement this unit.

Key Features

  • Three Height Configurations (24", 36", 48U): A single SKU covers three rack sizes — useful when you're standardizing across sites with different density requirements. The 48U variant handles a full complement of patch panels, switches, and edge appliances without stacking separate enclosures.
  • Swing Handle Access Control: The standard swing handle keeps unauthorized personnel out without requiring a key or credential — appropriate for low-security back-of-house locations like wiring closets in controlled facilities. Fast access for your network team during maintenance windows.
  • SEAL Combo Lock Option: The SEAL combination lock provides a step up in access control without adding infrastructure complexity. No badge reader, no power run — just a configurable mechanical combo that works during a power outage. Right for remote branch offices where IT staff are infrequent visitors.
  • SEAL Electronic Lock Option: Electronic access control via the SEAL Electronic variant integrates with credential management systems, providing an audit trail of who opened the enclosure and when. This matters in regulated environments (HIPAA, PCI-DSS, SOC 2) where access logging is a compliance requirement, not just a best practice.
  • Airflow Flexibility — None, Fan, or Clear Panel: Three airflow configurations mean you match the enclosure to the heat load of its contents. Passive (None) works for low-density patch panels. Fan-equipped handles switches and active gear running 24/7. Clear panel keeps the cavity ventilated while maintaining a physical barrier — common in shared spaces where visibility into the enclosure aids troubleshooting without opening the door.
  • Gray Finish: The gray finish blends into standard commercial and data center environments. Less visually intrusive than black in bright office or healthcare corridors, which matters when the enclosure is customer-facing or in a semi-public space.

Integration and Compatibility

The GL48WLP-B-SC-00 is designed to house standard 19-inch rack equipment. The electronic access control variant is compatible with access control systems that support dry-contact or relay-based door monitoring — verify your access control panel's input type before specifying the electronic option. For structured cabling deployments, pair with patch panels and cabling management accessories to complete the distribution frame. Teams running PoE network switches inside wall-mount enclosures should verify heat dissipation against the fan configuration to avoid thermal throttling on active ports. For full-site rack planning, review the rack and enclosure selection guide to match rack depth, load rating, and airflow strategy to your deployment.

Frequently Asked Questions

Q: What access control options are available on the GL48WLP-B-SC-00?

A: Three options: Swing Handle (standard mechanical), SEAL Combo (configurable combination lock, no power required), and SEAL Electronic (credential-based with audit capability).

Q: What rack heights does the GL48WLP-B-SC-00 support?

A: The enclosure is available in 24U, 36U, and 48U configurations under this product family.

Q: What airflow configurations are available?

A: Three configurations: None (passive), Fan (active cooling for heat-producing gear), and Clear panel (ventilated barrier).

Q: Is the GL48WLP-B-SC-00 suitable for active network equipment like PoE switches?

A: Yes, provided you specify the Fan airflow configuration to manage heat from continuously powered active gear. Passive (None) is appropriate only for low-density passive infrastructure like patch panels.

Q: Does the electronic lock option require a separate power supply?

A: Electronic access control typically requires a low-voltage power input and integration with an access control panel. Confirm wiring and power requirements with your access control system vendor before installation.

James Everett
James Everett

The GL48WLP-B-SC-00 is one of those enclosures I recommend when a project has a wiring closet that needs to look professional and stay locked — the three-tier access control stack (swing handle → SEAL combo → SEAL electronic) means you can spec this across a multi-site rollout and match the lock type to each site's security posture without sourcing three different enclosures.

Technical Highlights:

  • SEAL Electronic Access Control: Provides a hardware-enforced audit trail on enclosure entry — directly addresses compliance requirements in regulated verticals where a simple key log isn't sufficient evidence during an audit.
  • Fan Airflow Option: Active cooling inside a wall-mount is the difference between a switch running at 45°C and one throttling at 75°C. Specify fan-equipped whenever active PoE gear occupies more than half the usable U-space.
  • 24U / 36U / 48U Flexibility: Standardizing on this SKU family across a 20-site campus deployment lets your team carry consistent spare parts and mounting hardware — a real operational advantage at scale.

Deployment Considerations:

  • Wall-load capacity: always verify the wall structure (stud spacing, drywall vs. masonry) can support the combined weight of the enclosure plus fully loaded active gear before mounting — this is the most commonly skipped step on wall-mount installs.
  • The SEAL Electronic option adds wiring complexity; budget conduit and low-voltage cable runs to the enclosure location during rough-in, not after drywall is closed.

This enclosure is well-positioned for healthcare branch offices and education IDF closets where access logging is required, physical space is constrained, and IT staff visit infrequently — the SEAL Electronic variant paired with the fan airflow option covers both the compliance and thermal angles in a single unit.

Specifications
Height: 24"36"48"
Access Control: Swing HandleSEAL ComboSEAL Electronic
Airflow: NoneFanClear
freight: 565.40
Q&A
Reviews

Vertiv WLP WM 6-10 UX27X10 Gray - GL48WLP-B-SC-00

$1,670.00
$1,138.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources