Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL36WLP-B-SE-00 Wall-Mount Low-Profile Enclosure

Overview

The Vertiv GL36WLP-B-SE-00 is a wall-mount low-profile cabinet designed for network closets, IDF rooms, and distributed equipment deployments where floor space is limited but secure, organized equipment housing is still required. Available in 24", 36", and 48" height configurations, this enclosure from the Vertiv wall-mount enclosure line gives integrators flexibility to match rack unit requirements without over-sizing the installation footprint. The gray finish suits standard IT and security infrastructure environments.

Three access control options — Swing Handle, SEAL Combo, and SEAL Electronic — let you match physical security posture to the sensitivity of the equipment housed inside. The SEAL Electronic option is particularly relevant in multi-tenant buildings or secured areas where audit-trail access control is expected by compliance teams. For wall-mount network enclosures, this tiered access approach is a practical differentiator over basic cam-lock alternatives.

Key Features

  • Three Height Options (24", 36", 48"): Selecting the right height at spec time avoids costly mid-project enclosure swaps — 24" suits shallow IDF closets and small security head-end deployments, while 48" accommodates full access control panels, patch fields, and associated switching in a single cabinet.
  • Swing Handle Access Control: The standard mechanical option keeps entry fast for authorized technicians during routine maintenance — no combination memorization or credential provisioning required. Appropriate for low-sensitivity back-of-house locations.
  • SEAL Combo Lock: Keyless mechanical access eliminates the lost-key problem common in facilities with rotating maintenance staff — no rekeying cost, no locksmith calls.
  • SEAL Electronic Lock: Credential-based electronic access supports auditable entry logging, making this option suitable for deployments in PCI-DSS, HIPAA, or physically secured areas where access records are required. Pair with your access control infrastructure if badge-reader integration is planned.
  • Airflow Configurations (None / Fan / Clear): The fan option provides active thermal management for heat-sensitive gear like PoE switches or NVRs mounted inside — critical in non-air-conditioned closets where passive cooling isn't sufficient. The clear door option supports passive convection and visual status checks without opening the cabinet.

Integration and Compatibility

The GL36WLP-B-SE-00 (often searched as GL36WLP B SE 00) is suited for housing security and network equipment in wall-mount configurations — NVRs, access control panels, small PoE switches, and patch panels are common inhabitants. The enclosure fits within the broader rack and enclosure infrastructure ecosystem and is sourced factory-new with no grey-market substitutions. Confirm mounting surface load ratings before installation: wall-mount enclosures fully loaded with active equipment can exceed 150 lbs depending on configuration, and stud or structural blocking is typically required rather than drywall anchors alone.

For deployments pairing this enclosure with active network or security gear, review your PoE switch sizing to ensure the chosen airflow configuration can handle the thermal load of the equipment you plan to house.

Frequently Asked Questions

Q: What height options are available for the Vertiv GL36WLP-B-SE-00?

A: The GL36WLP-B-SE-00 is available in 24", 36", and 48" height configurations, allowing you to match the enclosure to your rack unit requirements and available wall space.

Q: What access control options does the GL36WLP-B-SE-00 support?

A: Three options are available: Swing Handle (standard mechanical), SEAL Combo (keyless combination lock), and SEAL Electronic (credential-based electronic lock suitable for auditable-access environments).

Q: Does the GL36WLP-B-SE-00 support active cooling?

A: Yes. Airflow configuration options include None (no active cooling), Fan (active thermal management), and Clear (passive convection with a clear door panel for visual access).

Q: Is the GL36WLP-B-SE-00 appropriate for housing NVRs or PoE switches?

A: Yes, wall-mount low-profile enclosures in this family are commonly used to house NVRs, access control panels, small PoE switches, and patch panels in IDF rooms and security head-end locations. Select the fan airflow option if housing heat-generating active equipment in non-air-conditioned spaces.

Q: What wall construction is required for mounting the GL36WLP-B-SE-00?

A: Wall-mount enclosures of this type require structural support — stud mounting or wall blocking is standard practice. Drywall anchors alone are generally insufficient for fully loaded enclosures. Verify your wall construction and load capacity before installation.

James Everett
James Everett

The GL36WLP-B-SE-00 is the enclosure I reach for when a project needs a clean, auditable head-end in a space that can't spare floor area. The SEAL Electronic access control option is the spec that matters most on regulated-site deployments — it separates this from a basic locked cabinet and puts it in the same conversation as the broader physical security layer, not just the IT closet furniture.

Technical Highlights:

  • Height Flexibility (24"/36"/48"): Specifying the right height up front matters — a 24" unit fits a shallow alcove but won't accommodate a full access control panel plus a managed switch; the 48" gives you room to grow without a second enclosure.
  • SEAL Electronic Lock: Credential-based access means you can enforce and log who opened the cabinet and when — a real requirement on PCI-DSS scoped infrastructure or in multi-tenant MDU deployments where shared closets are the norm.
  • Fan Airflow Option: Active cooling in a sealed wall-mount enclosure is non-negotiable if you're housing a PoE switch with a 30W+ budget or an NVR with spinning drives — passive-only configurations in unconditioned closets routinely overheat equipment within the first summer.

Deployment Considerations:

  • Confirm wall construction before committing to a mounting location — structural blocking or stud spacing must support the fully loaded weight of the enclosure and all housed equipment; gypsum anchors are not adequate.
  • The three airflow options are not field-convertible after purchase — select Fan if there is any possibility of housing heat-generating active equipment, even if the initial load is light.

This enclosure is a strong fit for mid-size commercial security head-end deployments: a 48" unit with SEAL Electronic access and fan airflow can cleanly house an NVR, access control panel, small managed switch, and patch field in a single locked, auditable cabinet in an IDF room or secured closet.

Specifications
Height: 24"36"48"
Access Control: Swing HandleSEAL ComboSEAL Electronic
Airflow: NoneFanClear
Q&A
Reviews
Have Questions?

Vertiv WLP WM 6-10 UX27X10 Gray - GL36WLP-B-SE-00

$2,239.00
$1,521.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources