Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL36WDXM-B-SC-AF 18U Wall-Mount Mesh Rack with Fan and SEAL Combo Lock

Overview

The Vertiv GL36WDXM-B-SC-AF is an 18U wall-mount enclosure built for edge deployments, telecommunications closets, and security equipment rooms where floor space is not available but reliable airflow and access control still matter. Available in 11U (24"), 18U (36"), and 25U (48") height configurations within the WDX family, this specific model ships in the 18U/36" form factor with a black finish, mesh door, active fan module, and SEAL Combo locking mechanism — a combination that addresses three of the most common failure modes in wall-hung network and surveillance hardware: heat buildup, unauthorized physical access, and poor cable management.

If you're sourcing Vertiv wall-mount racks for a distributed surveillance or network infrastructure project, the GL36WDXM-B-SC-AF lands in the middle of the WDX depth range at 24 inches — enough clearance for most PoE switches, patch panels, NVRs, and UPS units without projecting excessively from the wall.

Key Features

  • Mesh Front Door: The perforated mesh door allows passive convective airflow even when the fan isn't running at full speed — a meaningful advantage in warm IT closets where a solid door would trap heat around active switching or NVR hardware. If your equipment runs hot, this is the door style you want, not plexi or solid.
  • Active Fan Module (Fan Airflow Configuration): The GL36WDXM-B-SC-AF ships with a fan airflow option rather than a passive-only setup. Active cooling in a wall-mount enclosure matters most in sealed rooms, high-density PoE deployments, or any location where ambient temperature climbs above 77°F. The fan pulls heat away from equipment before it can degrade switch or recorder performance.
  • SEAL Combo Access Control: The SEAL Combo lock provides keyless combination access — no key management, no lockouts from lost keys, and no need to coordinate with facilities for physical key copies. For distributed security deployments across multiple sites where technicians rotate, a combination lock is often more practical than key-based options. The WDX line also supports Swing Handle and SEAL Electronic variants if your access control policy requires audit-trail logging.
  • 18U Capacity (36" Height): Eighteen rack units of usable space covers a typical edge security stack: a PoE switch (1–2U), an NVR (2–4U), a patch panel (1–2U), a small UPS (2U), and still leaves room for future expansion. The 18U form factor is the most commonly specified for security closets in commercial buildings — deep enough to be useful, compact enough to comply with most wall-mount structural load limits.
  • 24" Mounting Depth: At 24 inches, this enclosure accommodates full-depth 1U switches and recorders without shimming or modified mounting rails. Shallower 12" or 18" wall mounts frequently force workarounds for standard-depth gear; this depth eliminates that problem for the vast majority of commercial security and IT equipment.
  • Black Finish: The black powder-coat finish blends into server room environments and reduces visual footprint in customer-facing spaces like retail back-of-house or lobby IT closets. Functionally equivalent to the grey variant — finish choice is aesthetic and occasionally specified by interior design standards.
  • Multiple Configuration Options in the WDX Family: The WDX line spans 11U through 25U heights, three door styles (Mesh, Plexi, Solid), three access control options (Swing Handle, SEAL Combo, SEAL Electronic), and three airflow options (None, Fan, Clear). This means the GL36WDXM-B-SC-AF can be cross-referenced against sibling models if your project requires a different door or lock type without changing the enclosure depth or footprint.

Integration and Compatibility

The GL36WDXM-B-SC-AF follows standard 19-inch EIA rack rail spacing, making it compatible with any 19" rackmount equipment — PoE switches, network video recorders, patch panels, fiber distribution units, and small-form UPS devices. The 24" depth accommodates virtually all 1U and 2U commercial network and surveillance equipment without requiring extender rails. For projects where power protection is part of the stack, consult the UPS and power conditioning category to identify units that fit the 18U envelope. If access control logging is required at this enclosure, the SEAL Electronic variant (a sibling in the WDX line) provides electronic credential management; the SEAL Combo on this model does not produce an access log.

For teams planning a wall-mount rack deployment across multiple sites, the WDX family's consistent rail geometry means accessories, blanking panels, and cable management hardware are interchangeable across height variants — reducing the parts list for multi-site rollouts.

Frequently Asked Questions

Q: What is the usable rack space in the GL36WDXM-B-SC-AF?

A: The GL36WDXM-B-SC-AF is an 18U enclosure with a 36-inch overall height. The WDX family also includes 11U (24") and 25U (48") height variants if you need more or less capacity.

Q: Does the GL36WDXM-B-SC-AF include active cooling?

A: Yes. This model ships in the Fan airflow configuration, which means an active fan module is included. The WDX line also offers None (passive only) and Clear (no door restriction) airflow options in sibling models if your thermal requirements differ.

Q: What type of lock does the GL36WDXM-B-SC-AF use?

A: It uses a SEAL Combo lock — a keyless combination mechanism. The WDX family also offers Swing Handle (no lock) and SEAL Electronic (electronic credential with audit trail) options. The Combo lock does not produce an access log; if audit logging is required, specify the SEAL Electronic variant.

Q: Will standard 19-inch 1U and 2U equipment fit in the GL36WDXM-B-SC-AF?

A: Yes. The enclosure uses standard EIA 19-inch rail spacing and has a 24-inch mounting depth, which accommodates full-depth 1U switches, NVRs, and patch panels without extender rails.

Q: What door style does the GL36WDXM-B-SC-AF have?

A: This model ships with a mesh front door, which allows airflow even during passive operation. The WDX line also offers Plexi (transparent, closed) and Solid door options if your environment requires a different configuration.

Q: Can the GL36WDXM-B-SC-AF be used in a multi-site security deployment where technicians rotate between locations?

A: Yes. The SEAL Combo lock is well-suited to multi-site deployments because it eliminates key management — technicians can be given the combination without issuing physical keys, and the combination can be changed without a locksmith. If you need per-technician access logging, the SEAL Electronic variant is the appropriate upgrade.

Eden Phillips
Eden Phillips

The GL36WDXM-B-SC-AF sits in the sweet spot of the Vertiv WDX wall-mount line for edge security installs — the 18U/36" height gives you enough runway to build a real stack (switch, NVR, patch panel, UPS) without exceeding typical wall-mount structural limits, and the Fan airflow configuration means you're not gambling on passive convection alone in a warm telecom closet.

Technical Highlights:

  • Fan Airflow Configuration: Active cooling in a wall-mount enclosure is the difference between equipment running at rated temperature and thermal throttling or early failure in any closet that sees ambient temps above 77°F — a common condition in commercial mechanical rooms and retail back-of-house locations.
  • Mesh Door: Even when the fan cycles down, the mesh door maintains convective airflow across front-mounted switch and NVR ports. A solid or plexi door in the same scenario traps heat; this door doesn't.
  • SEAL Combo Lock: For multi-site security integrators managing 10+ locations, combination locks reduce service calls from locked-out technicians and eliminate the facilities coordination overhead that key-based locks require. No key inventory to track, no re-keying cost when personnel changes.

Deployment Considerations:

  • The 24" depth handles full-depth 1U and 2U gear cleanly, but verify wall stud spacing and load rating before specifying for heavier NVR configurations — a fully loaded 18U enclosure with a UPS can approach or exceed 150 lbs depending on equipment.
  • The SEAL Combo lock does not log access events. If your security policy or compliance framework requires an audit trail of who opened the enclosure and when, this model is the wrong choice — specify the SEAL Electronic variant instead.

This enclosure is a strong fit for commercial building security closets, retail back-office NVR installations, and distributed enterprise edge deployments where the thermal and access-control configuration of GL36WDXM-B-SC-AF aligns with the site conditions — active cooling needed, key management not practical, 18U capacity sufficient.

Specifications
Height: 24" (11U)36" (18U)48" (25U)
Door: PlexiMeshSolid
Access Control: Swing HandleSEAL ComboSEAL Electronic
Airflow: NoneFanClear
freight: 565.40
Q&A
Reviews
Have Questions?

Vertiv WDX WM 18UX24X32 Mesh Black Combo FAN - GL36WDXM-B-SC-AF

$2,286.00
$1,550.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources