Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv CPQ-1052342-01 240V 30A Rackmount Power Distribution Unit

The Vertiv CPQ-1052342-01 is a rackmount power distribution unit (PDU) rated at 240V / 30A with an L14-30P input connector and 12 output receptacles — sized for server rooms, network closets, and edge data center deployments where a single, high-amperage 240V feed needs to be split cleanly across multiple loads. The CPQ-1052342-01 (often searched as CPQ 1052342 01) is sourced factory-new through channel-direct supply with no grey-market risk.

Overview

Rack power distribution is one of those specs buyers often underestimate until a mismatch causes a rollback. This unit is engineered around a 30A / 240V input on a locking L14-30P plug — meaning it won't pull from a standard 20A branch circuit by accident. The 12-outlet configuration gives enough receptacle density for a moderately loaded rack without requiring a second PDU run. The -R suffix in the product family name indicates rackmount form factor, compatible with standard 19-inch EIA rack infrastructure.

Key Features

  • L14-30P Locking Input Connector: The twist-lock L14-30P plug mates to a standard NEMA L14-30R receptacle and physically locks in place — no accidental disconnection under rack vibration or during cable management work. This is the correct input for 240V / 30A dedicated branch circuits found in most data center and telecom room designs.
  • 30A / 240V Capacity: A 30-amp 240V feed delivers up to 7,200W of available power before derating — enough headroom for a dense 1U/2U server rack or a network equipment cabinet loaded with switches, patch panels, and PoE injectors. Budget to 80% of nameplate (5,760W continuous) per NEC 210.19(A).
  • 12 Output Receptacles: Twelve outlets on a single feed keeps per-rack cabling clean. For a UPS and power management strategy, pair this PDU downstream of a compatible Vertiv UPS to extend runtime coverage across all 12 connected loads simultaneously.
  • Rackmount Form Factor: Designed for 19-inch standard rack rails, this unit installs vertically or horizontally (confirm U-height with Vertiv documentation for your specific installation). The rackmount profile keeps outlet access clean and avoids floor-standing power strips that violate raised-floor airflow planning.
  • Vertiv Platform Compatibility: As part of the broader Vertiv power and infrastructure lineup, the CPQ-1052342-01 integrates with Vertiv's broader rack power ecosystem, including compatible UPS systems and monitoring infrastructure where applicable.

Integration & Compatibility

The L14-30P input on this unit requires a matching L14-30R receptacle at the panel or UPS output — verify your upstream power source before ordering. Standard 240V / 30A dedicated branch circuits in North American data centers, telecom rooms, and edge deployments will be compatible. This PDU is appropriate for network infrastructure racks housing switches, routers, NAS units, and similar equipment drawing from a shared 240V feed. If your rack load exceeds the 30A nameplate or requires 208V three-phase distribution, evaluate higher-amperage or three-phase Vertiv PDU variants in the same family. For deployments requiring intelligent per-outlet monitoring or remote switching, confirm with Vertiv whether a managed PDU variant in this family better fits your power monitoring requirements — the CPQ-1052342-01 spec evidence does not indicate built-in remote management capability.

Frequently Asked Questions

Q: What input connector does the CPQ-1052342-01 use?

A: The CPQ-1052342-01 uses an NEMA L14-30P locking plug, which connects to a standard L14-30R receptacle. This is a 240V, 30A twist-lock connector common in North American data center and commercial electrical installations.

Q: How many outlets does the CPQ-1052342-01 provide?

A: The CPQ-1052342-01 provides 12 output receptacles, suitable for distributing power across multiple servers, switches, or other rack-mounted equipment from a single 30A / 240V feed.

Q: What is the maximum power capacity of the CPQ-1052342-01?

A: At 240V / 30A, the nameplate capacity is 7,200W. Per NEC 210.19(A), continuous loads should be derated to 80% of nameplate — plan for a maximum of 5,760W of sustained draw across all connected equipment.

Q: Does the CPQ-1052342-01 fit a standard 19-inch rack?

A: Based on the product family designation (the -R suffix indicating rackmount), this PDU is designed for standard 19-inch EIA rack installation. Confirm exact U-height and rail compatibility with Vertiv product documentation prior to deployment.

Q: Is the CPQ-1052342-01 compatible with Vertiv UPS systems?

A: The CPQ-1052342-01 is part of the Vertiv infrastructure lineup. For UPS pairing, ensure the upstream Vertiv UPS provides an L14-30R output at 240V / 30A or higher capacity. Specific UPS model compatibility should be confirmed against Vertiv's system documentation.

Marty Allison
Marty Allison

When I review a PDU order for a rack deployment, the first thing I check is the input connector and amperage — and the CPQ-1052342-01 gets those right for a specific job: 240V / 30A on a locking L14-30P, feeding 12 receptacles. That combination targets the mid-density rack that's too loaded for a single 20A circuit but doesn't yet need a three-phase or dual-feed solution.

Technical Highlights:

  • L14-30P Locking Input: The twist-lock mechanism is underrated — in a busy data center where someone is always pulling cables, a locking connector on your main feed is a real safeguard. It won't pull free without deliberate quarter-turn release.
  • 30A / 240V Rating: At 7,200W nameplate (5,760W derated for continuous NEC-compliant operation), this unit has enough capacity for a rack of 1U servers or a network closet loaded with managed switches and PoE infrastructure — without pushing a 20A circuit into thermal stress.
  • 12-Outlet Configuration: Twelve receptacles is the sweet spot for single-PDU coverage in a half-loaded rack. Avoids the cable sprawl of daisy-chaining two smaller units and keeps your power audit clean at the panel.

Deployment Considerations:

  • Verify your upstream panel or UPS output provides an L14-30R receptacle at 240V / 30A before procurement — retrofitting a mismatched outlet is a delay you don't want on a rollout timeline.
  • The available evidence does not confirm built-in remote monitoring or per-outlet switching on this unit. If your operations team requires remote power cycling or per-outlet metering, evaluate managed PDU variants in the Vertiv lineup before finalizing this SKU.

The CPQ-1052342-01 is the right call for a server room or network closet deployment where you have a dedicated 240V / 30A branch circuit, need clean distribution across 12 loads, and want the mechanical reliability of a locking L14-30P input — not for high-density blade environments or three-phase deployments where you'd need a higher-capacity or intelligent PDU.

Specifications
Sku: CPQ-1052342-01
Input Connector: L14-30P
Amperage Rating: 30A
Voltage Rating: 240V
Number of Outlets: 12
Q&A
Reviews
Have Questions?

Vertiv VPN-ERV_L14-30P-30A_24NO-12D-R - CPQ-1052342-01

$4,098.00
$2,810.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services