APC by Schneider Electric Vision 2000MM LIB Rack with 8 X 100AH Battery Modules - LIBVIS8X100630IEC

APC by Schneider Electric LIBVIS8X100630IEC Li-Ion Battery Rack — 8-Module, 1000Ah, 630A CBMS IECOverviewThe LIBVIS8X100630IEC is a high-capacity lith…

$65,170.00 $44,155.99 SAVE $21014
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Vision 2000MM LIB Rack with 8 X 100AH Battery Modules - LIBVIS8X100630IEC

$65,170.00
$44,155.99

Overview

SKU: LIBVIS8X100630IEC
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric LIBVIS8X100630IEC Li-Ion Battery Rack — 8-Module, 1000Ah, 630A CBMS IEC

Overview

The LIBVIS8X100630IEC is a high-capacity lithium-ion battery rack designed for large-scale power continuity applications requiring a modular, high-current approach. Configured as a 2000mm tower housing eight 100Ah lithium-ion battery modules for a combined 1000Ah capacity, this unit pairs with a 630A Circuit Breaker Management System (CBMS) on an IEC bus — making it suited for data centers, critical facility infrastructure, and industrial UPS deployments where conventional lead-acid strings fall short on density and cycle life. If you're specifying power and UPS solutions that need to scale without floor-space penalties, the lithium-ion chemistry here is a meaningful operational advantage over legacy valve-regulated lead-acid (VRLA) racks.

Key Features

  • Lithium-Ion Chemistry (8 × 100Ah Modules): Li-Ion cells deliver significantly higher cycle counts and a longer service life than VRLA equivalents, reducing replacement frequency and total cost of ownership in facilities running 24/7. The modular design — eight discrete 100Ah units — means you can service or replace a single module without taking the entire string offline, which matters in environments where planned maintenance windows are hard to schedule.
  • 1000Ah Total Capacity: At 1000Ah, this rack supports extended runtime demands. Exact runtime depends on the connected load and system voltage — confirm those parameters with your UPS architecture before specifying. This is not a unit to size by capacity alone.
  • 630A CBMS with IEC Bus: The integrated 630A Circuit Breaker Management System provides overcurrent protection and bus management at the rack level. The IEC connector standard ensures broad compatibility with IEC-standard UPS and distribution equipment across major vendors.
  • 2000mm Tower Form Factor (600 × 1000mm Footprint): The 2000mm height fits standard data center row infrastructure. At 600mm wide and 1000mm deep, floor planning is straightforward — verify your raised-floor or slab load rating before deployment, since the unit ships at approximately 120 kg (265 lbs) and will weigh more fully populated with battery modules.
  • Grey/White Finish: The dual-tone grey and white finish is consistent with APC by Schneider Electric's Symmetra and Galaxy ecosystem aesthetics, simplifying visual integration in mixed-vendor equipment rooms.

Frequently Asked Questions

Q: What is the total battery capacity of the LIBVIS8X100630IEC?

A: The LIBVIS8X100630IEC holds eight 100Ah lithium-ion battery modules for a combined 1000Ah total capacity.

Q: What does the 630A CBMS IEC designation mean on this unit?

A: CBMS stands for Circuit Breaker Management System. The 630A rating indicates the overcurrent protection level at the bus, and IEC denotes the connector/bus standard used — confirm compatibility with your UPS and distribution equipment specifications before ordering.

Q: How much does the LIBVIS8X100630IEC weigh?

A: The packaged weight is approximately 120 kg (265 lbs). Plan your floor loading and installation crew accordingly — this is a two-person minimum lift, and raised-floor tiles must be rated for the concentrated load.

Q: Can individual battery modules be replaced without taking the whole rack offline?

A: The modular design with eight discrete 100Ah units is intended to support per-module serviceability, but confirm hot-swap capability and maintenance procedures with APC's technical documentation for your specific UPS architecture before relying on online replacement.

Q: What voltage does the LIBVIS8X100630IEC operate at?

A: Nominal system voltage is not confirmed in available evidence. Contact APC or your UPS vendor to verify voltage compatibility with your existing infrastructure before specifying this unit.

Marty Allison
Marty Allison

When I look at the LIBVIS8X100630IEC, the spec that stands out immediately is the 630A CBMS rating on an IEC bus — that's a significant current ceiling, and it tells me this rack is designed for large UPS architectures where battery strings feed high-current distribution switchgear, not small server closets. Combined with eight 100Ah lithium-ion modules totaling 1000Ah, you're looking at a system built for runtime-critical applications at scale.

Technical Highlights:

  • Modular 8 × 100Ah Architecture: Eight discrete modules mean granular serviceability — if one module degrades, you're not pulling the whole string. This is operationally significant in facilities where MTTR on power infrastructure directly impacts SLA compliance.
  • Lithium-Ion Chemistry: Li-Ion's cycle-life advantage over VRLA is well established — typically 3–5x more cycles before capacity fade — which translates to fewer replacement events and lower long-run operating costs in 24/7 data center or industrial environments.
  • 2000mm Tower at 120 kg Packaged: The full-height 2000mm enclosure maximizes module density in a standard data center row footprint (600 × 1000mm), but that 120 kg shipping weight means you need to account for floor loading and have the right lift equipment on-site before delivery day.

Deployment Considerations:

  • Voltage compatibility is not confirmed in available published specs — this is a non-negotiable pre-order verification. Mismatched bus voltage between this rack and your UPS is a commissioning failure, not a firmware fix.
  • At 120 kg packaged, installation requires at minimum a two-person team and likely a pallet jack or lift gate for data center floor placement — plan logistics before the unit arrives, not after.

This unit is best positioned for large facility UPS refreshes — enterprise data centers, industrial process control rooms, or utility-adjacent infrastructure — where lithium-ion density and modular serviceability justify the specification over legacy lead-acid string replacements.

Specifications
Form factor: Tower
Product colour: Grey, White
Battery technology: Lithium-Ion (Li-Ion)
Number of batteries supported: 8
Battery capacity: 1000 Ah
Quantity: 1
Package width: 600 mm
Package depth: 1000 mm
Package height: 2000 mm
Package weight: 120 kg
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources