Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv PSI5-1100MT120 1100VA/990W Line-Interactive Mini Tower UPS

Overview

The Vertiv PSI5-1100MT120 is a 1,100 VA / 990 W line-interactive UPS in a compact mini tower form factor, designed for small server rooms, edge deployments, and surveillance head-end equipment where clean, regulated power is non-negotiable. At up to 97% efficiency in Normal Mode, it draws minimal overhead on your utility bill even running 24/7 — an important factor when stacking multiple UPS units in a security operations room. The built-in Automatic Voltage Regulation (AVR) topology keeps connected equipment online through sags and swells across a wide 75–146VAC input window, stepping in with battery power only when conditions fall outside that range — extending battery service life compared with double-conversion designs that cycle the battery on every minor disturbance.

For integrators specifying power protection alongside Vertiv power infrastructure or planning a complete UPS and power protection deployment, the PSI5-1100MT120 (often searched as PSI5 1100MT120) occupies the sweet spot between desktop-grade strip protection and rack-mounted enterprise UPS.

Key Features

  • 1,100 VA / 990 W Power Capacity: Enough headroom to carry a compact NVR, managed PoE switch, and ancillary networking gear simultaneously. Size to 80% load for runtime margin — that puts your practical ceiling around 792 W of connected load before runtime begins to compress.
  • Up to 97% Efficiency in Normal Mode: Line-interactive topology running near-unity efficiency means the PSI5-1100MT120 generates very little heat and adds minimal load to your facility circuits. In a closet with limited airflow, this matters more than the spec sheet implies.
  • Wide Input Range (75–146VAC): AVR steps up or down within this window without touching the battery. In buildings with known voltage instability — older facilities, construction-adjacent sites, or rural installations — this range catches most brownouts and swells that would otherwise age your connected equipment prematurely.
  • User-Configurable Output Voltage (100/110/115/125VAC): Lets you tune the output to match sensitive equipment tolerances or local standards without rewiring. Useful when integrating international equipment or when downstream devices specify a tighter input window than nominal 120VAC.
  • 5 × NEMA 5-15R Output Receptacles: Five individually accessible outlets on a 5-15P input plug — no IEC adapters needed in standard North American deployments. Layout the load across outlets with attention to which are battery-backed vs. surge-only if applicable to your configuration.
  • LCD Control Panel: Front-panel display gives real-time UPS status — load level, battery state, input/output voltage — without requiring a laptop or SNMP connection. Useful during commissioning and for quick field checks.
  • Flexible Communications Options: USB and RJ-45 ports are onboard. Optional UNITY communications cards (IS-UNITY-SNMP or IS-UNITY-DP) add SNMP and web management for remote monitoring via your NMS. EPO terminals support emergency power-off integration with building management or data center control systems.
  • Out-of-Band Serial Management: Serial connection for management independent of the primary network — critical when a network event is the cause of the outage you're trying to diagnose.
  • Operating Temperature +32 to +104 °F (0–40 °C): Covers standard conditioned space deployments. Not rated for uncontrolled outdoor enclosures or unconditioned attic installations — factor this into site surveys for remote edge locations.
  • Compliance: UL 1778, ANSI C62.41 Cat A Level 3, RoHS2, REACH: UL 1778 is the North American safety standard for UPS equipment. ANSI C62.41 Category A Level 3 reflects surge immunity testing at the branch-circuit level. RoHS2 and REACH compliance matter for enterprise procurement teams with environmental reporting requirements.

Integration & Compatibility

The PSI5-1100MT120 integrates with network management platforms via optional UNITY SNMP cards, enabling trap-based alerting and SNMP polling from tools like SolarWinds, PRTG, or Nagios. The USB interface supports UPS-to-server communication for graceful shutdown sequencing — pair it with the Vertiv Intelligent Power Transfer (IPT) software or compatible open-source agents. EPO terminal integration connects to building emergency stop systems, a common requirement in data center and campus security head-end builds. For broader power protection planning, consider pairing this unit with a dedicated surge protection device on the utility feed side for layered transient suppression beyond what the internal AVR provides.

Frequently Asked Questions

Q: What is the input plug and output receptacle configuration on the PSI5-1100MT120?

A: The PSI5-1100MT120 uses a NEMA 5-15P input plug and provides five NEMA 5-15R output receptacles — standard North American 15A configuration. No adapters required for typical US deployments.

Q: Does the PSI5-1100MT120 include an SNMP card, or is that sold separately?

A: SNMP capability requires an optional communications card — either the IS-UNITY-SNMP or IS-UNITY-DP — sold separately. The base unit includes USB and RJ-45 interfaces onboard, along with EPO terminals.

Q: What is the input voltage range the PSI5-1100MT120 can handle before switching to battery?

A: The AVR topology accepts input from 75 to 146VAC without engaging the battery. Outside that window, the unit transfers to battery. Nominal input is 120VAC.

Q: Can I configure the output voltage on the PSI5-1100MT120?

A: Yes. Output voltage is user-configurable among 100, 110, 115, and 125VAC via the onboard LCD control panel, allowing you to match downstream equipment tolerances without rewiring.

Q: What certifications does the PSI5-1100MT120 carry?

A: The unit is listed to UL 1778 (North American UPS safety standard), ANSI C62.41 Category A Level 3 (surge immunity), RoHS2, and REACH.

Q: Is the PSI5-1100MT120 rack-mountable?

A: The PSI5-1100MT120 ships in a mini tower form factor. Rack conversion options may be available separately — consult Vertiv accessories for compatible rail kits if rack integration is required.

Karl Wilson
Karl Wilson

The PSI5-1100MT120's 97% Normal Mode efficiency is the spec I keep coming back to when specifying this unit for edge surveillance closets — at 990 W capacity running near-continuously, you're dissipating very little heat compared with older ferro-resonant or double-conversion alternatives of similar capacity. That thermal advantage is real in a locked IDF closet with passive ventilation.

Technical Highlights:

  • 97% Efficiency (Normal Mode): Minimizes heat output and facility power draw in 24/7 operation — meaningful when multiple UPS units share a small, lightly cooled space.
  • 75–146VAC AVR Input Window: Catches a wide band of voltage disturbances without cycling the battery, extending battery service intervals in electrically noisy environments like industrial facilities or older commercial buildings.
  • Optional UNITY SNMP/DP Cards: Add IS-UNITY-SNMP or IS-UNITY-DP to pull this unit into your NMS with full SNMP trap and web management — the base unit ships without this capability, so budget for it if remote monitoring is a requirement.

Deployment Considerations:

  • Size connected load to 80% of the 990 W rating (~792 W practical ceiling) to maintain meaningful runtime margin; an NVR, PoE switch, and fiber media converter typically land well within that envelope.
  • The mini tower form factor weighs 26 lb — plan for shelf or floor placement in the closet; rack mounting requires a separate conversion kit not included in the base SKU.

The PSI5-1100MT120 is well-matched to compact surveillance head-end builds: a single NVR, one managed PoE switch, and a network appliance sit comfortably inside the 990 W envelope, and the wide AVR input range handles the voltage irregularities common in warehouse and light-industrial sites without prematurely aging the battery.

Specifications
Weight: 26.0 lb
Height: 9.4 in
Width: 5.7 in
Depth: 14.8 in
Operating Temp: +32 to +104 °F (0 to 40 °C)
Power Rating: 1,100 VA / 990 W
Input Voltage Range: Nominal: 120VAC / Range: 75-146VAC
Output Voltage Range: 120VAC (100/110/115/125VAC user-configurable)
Efficiency: Up to 97% (Normal Mode)
Wiring: Input: 5-15P; Ouput: 5 x 5-15R
Interface Options: Optional communications card (IS-UNITY-SNMP, or IS-UNITY-DP), USB, RJ-45, EPO Terminals
Protocols: SNMP and web management enabled with optional UNITY communications cards; serial connection for out-of-band management
Control Panel: LCD display, provides insight to UPS status for easy installation, configuration and operation
Operating Temperature: +32 to +104 °F (0 to 40 °C)
Listings: ANSI C62.41 Category A, Level 3, UL 1778, RoHS2, REACH
Topology: Line-Interactive AVR UPS; compact mini tower form factor
Q&A
Reviews

Vertiv Liebert PSI5 1100 990W 120VAC - PSI5-1100MT120

$811.00
$556.99

RELATED PRODUCTS

Save $515.01
Vertiv Liebert PSI5 1100 990W 120VAC RT W/ RDU120 Card - PSI5-1100RT120N
Add to Cart The item has been added

Vertiv PSI5-1100RT120N

Vertiv Liebert PSI5 1100 990W 120VAC RT W/ RDU120 Card - PSI5-1100RT120N

1100VA/990W line-interactive Uninterruptible Power Supply (UPS) designed to protect critical IT infrastructure, including servers and network

    In stock · Ships same business day Free shipping over $499
    $1,641.00 $1,125.99 Save $515.01
    The item has been added Add to quote
    $1,641.00 $1,125.99 Save $515.01
    Save $515.01 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources