Altronix TROVE3M3/16DR/20A/220 - T3MK77F16QVFM
Power distribution module designed to provide regulated 12VDC or 24VDC output for up to sixteen surveillance cameras or other low-voltage devices
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Altronix T3MK7716LQVFM is a TROVE3M3-based integrated power and access control distribution package engineered for large-scale door deployments. Supporting up to 16 doors from a single enclosure at 20 amps across a 220V input, this unit consolidates power distribution, control wiring, and status monitoring into one cabinet — eliminating the rat's nest of discrete power supplies and homerun wiring that plagues multi-door installations. If you're commissioning a mid-to-large commercial facility where every homerun back to a central IDF or security closet adds cost and complexity, the T3MK7716LQVFM is designed specifically to compress that scope.
Altronix's TROVE series is purpose-built for integrators running multi-door access control at scale. This variant pairs a TROVE3M3 backplane with the power and output capacity to drive 16 reader/lock circuits without splitting the job across multiple enclosures. For anyone pricing a campus retrofit, hospital wing, or multi-tenant commercial build, consolidating to a single T3MK7716LQVFM per zone cuts both labor hours and service callbacks.
The TROVE3M3 platform is designed to integrate with compatible access control panels and boards from major manufacturers. The 16-door capacity and 20A power budget accommodate typical enterprise access controller configurations. Confirm your specific access control board's physical and electrical compatibility with the TROVE3M3 backplane dimensions before ordering — Altronix publishes board compatibility guides that specify which controller modules seat correctly in this enclosure. The 220V input requires a correctly rated branch circuit; coordinate with the electrical contractor early to avoid jobsite delays at energization.
Q: How many doors can the T3MK7716LQVFM support?
A: The T3MK7716LQVFM supports up to 16 doors from a single enclosure, making it suitable for large commercial floors, campus buildings, or multi-tenant facilities where centralizing access control power per zone reduces wiring complexity.
Q: What is the input voltage requirement for the T3MK7716LQVFM?
A: The T3MK7716LQVFM operates on a 220V input. Ensure your electrical contractor provisions a correctly rated 220V branch circuit and breaker before installation.
Q: What is the total output current capacity of the T3MK7716LQVFM?
A: The unit delivers 20A of total output power, sufficient to drive mixed loads including mag-locks, electric strikes, card readers, and REX devices across all 16 door circuits simultaneously with headroom remaining.
Q: Does the T3MK7716LQVFM include status indicators for individual outputs?
A: Yes. LED status indicators are included and provide per-circuit visual feedback at the enclosure, which accelerates fault isolation during commissioning and service calls without requiring a meter.
Q: What access control boards are compatible with the TROVE3M3 backplane in the T3MK7716LQVFM?
A: Altronix publishes a compatibility matrix for TROVE3-series enclosures listing supported access control boards by manufacturer. Confirm your specific controller module against that guide before ordering to ensure correct physical and electrical fit.
Q: Is the T3MK7716LQVFM suitable for international deployments?
A: The 220V input makes this unit well-suited for facilities where 220V distribution is standard, including many international commercial buildings, reducing or eliminating the need for step-down transformers.

The T3MK7716LQVFM is a unit I'd spec for any project where the door count crosses 8 and you're trying to keep the security closet footprint manageable. The 20A output budget at 220V is the practical spec to anchor your load calculation on — at 16 doors fully populated with 500mA mag-locks and 150mA readers, you're drawing roughly 10.4A, leaving 9.6A of headroom for door contacts, REX devices, and any future circuit additions without revisiting the panel.
Technical Highlights:
Deployment Considerations:
The T3MK7716LQVFM is the right specification for a mid-sized commercial tenant improvement or a campus building retrofit where a single security closet needs to own 16 doors cleanly — hospital floors, university classroom wings, and multi-tenant office builds are the natural fit.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Altronix products? Shop the full Altronix catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price