Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Altronix T2HW16Q Access and Power Integration Kit

Overview

The Altronix T2HW16Q is a factory-assembled access and power integration kit that combines an enclosure, power supply, and network communication module into a single deployable unit. Rather than sourcing and wiring these components separately, the T2HW16Q ships as a pre-configured assembly — reducing rack time on multi-door commercial access control deployments where clean, auditable power distribution is non-negotiable.

The kit is built around the TROVE2 enclosure paired with the THWD2 power supply and Altronix LINQ network management, delivering both 12VDC and 24VDC outputs under a single 115VAC feed. With 16A total output capacity across 8 individually managed outputs, it covers the power requirements of most mid-scale access control panels, electric locks, and credential readers without requiring a secondary power chassis.

Explore the full Altronix surveillance and access control line for compatible panels, power supplies, and enclosures, or browse the broader access control category to match the T2HW16Q with door controllers and credential hardware.

Key Features

  • Dual-Voltage Output (12VDC / 24VDC): Supporting both voltage rails from a single kit means you can power 12V credential readers and 24V electric strikes simultaneously without splitting across two chassis — critical on multi-door installations where voltage mismatches create service calls.
  • 16A Total Output Capacity: At 16A across 8 outputs, this kit supports a realistic mix of mag-locks, electric strikes, and reader hardware at full load. Average mag-lock draws 500mA–650mA at 12V; at 16A you have headroom for 20+ devices before hitting the ceiling — enough for a mid-floor wiring closet serving an entire access zone.
  • 8 Individually Managed Outputs: Eight discrete outputs let you map one circuit per controlled door or device group, simplifying fault isolation. When a door fails to release, you can trace the issue to a specific output without de-powering adjacent hardware.
  • LINQ Network Communication Module: The integrated LINQ module brings remote monitoring and management to the power supply — letting security operations staff verify output status, receive fault alerts, and document power events without dispatching to the MDF. For multi-site enterprise deployments, this is the difference between a service truck roll and a 2-minute remote diagnostic.
  • 115VAC / 60Hz Input: Standard North American single-phase input means no transformer or step-down converter is required in US installations — wire directly to a standard 20A commercial circuit.
  • Compact Enclosure (13″ × 12″ × 3.5″, 10 lbs): At under 3.5 inches deep, the T2HW16Q fits in shallow wall-mount or surface-mount wiring closets where full-depth enclosures won't clear conduit runs or door swing. At 10 lbs, a single technician can position and anchor it without a lift assist.
  • Pre-Integrated Kit Configuration: Factory assembly of the TROVE2 enclosure, THWD2 power supply, and LINQ module reduces field wiring errors and inspection time. On projects with AHJ oversight, a pre-configured assembly simplifies the inspection checklist compared to field-built equivalents.

Integration and Compatibility

The T2HW16Q is designed for commercial access control environments and pairs with standard access control power supplies and door hardware operating on 12VDC or 24VDC rails. The LINQ network module integrates with Altronix's network management ecosystem for centralized supervision. For installations requiring PoE-powered readers or IP-connected controllers, pair with a managed PoE switch mounted in the same IDF. The dual-voltage output is compatible with the wide majority of commercial mag-locks, electric strikes, and card readers available from major access control manufacturers.

If your project calls for supervised power with tamper detection and battery backup, verify whether the THWD2 component within this kit supports those features per the Altronix THWD2 datasheet — the T2HW16Q's kit configuration inherits those capabilities from its component modules.

Frequently Asked Questions

Q: What voltages does the T2HW16Q supply?

A: The T2HW16Q provides both 12VDC and 24VDC output, allowing simultaneous power to devices operating on either voltage rail from a single unit.

Q: How many outputs does the T2HW16Q have, and what is the total current capacity?

A: The kit provides 8 individually managed outputs with a combined maximum output current of 16A.

Q: What is the input power requirement for the T2HW16Q?

A: The T2HW16Q requires a standard 115VAC, 60Hz input — compatible with standard North American commercial circuits, no step-down transformer needed.

Q: What components are included in the T2HW16Q kit?

A: The T2HW16Q integrates the Altronix TROVE2 enclosure, THWD2 power supply, and LINQ network communication module as a factory-assembled unit.

Q: What are the physical dimensions and weight of the T2HW16Q?

A: The enclosure measures 13″ × 12″ × 3.5″ and weighs 10 lbs, making it suitable for shallow wall-mount or surface-mount installations in wiring closets.

Q: Can the T2HW16Q be monitored remotely?

A: Yes. The integrated LINQ network module enables remote monitoring and management of the power supply outputs, supporting fault detection and status reporting over the network without requiring physical access to the enclosure.

Karl Wilson
Karl Wilson

The T2HW16Q is one of those kits that makes more sense the further into a multi-door deployment you are. The 16A ceiling across 8 outputs is the practical detail — at typical mag-lock draw (500–650mA each at 12V), you can fully load all eight circuits before hitting the supply limit, which is exactly what you want on a floor-level IDF serving 6–8 controlled doors plus readers.

Technical Highlights:

  • Dual 12/24VDC Rails: Running both voltage rails from one kit eliminates the second enclosure that often creeps into single-voltage designs when the spec sheet calls for 24V strikes and 12V readers simultaneously.
  • LINQ Network Module: Remote output monitoring over the network means your NOC can log power events and flag faults without dispatching a tech to the IDF — operationally significant on campus or multi-building deployments where wiring closets are spread across a large footprint.
  • 3.5″ Depth, 10 lbs: The shallow profile fits cleanly in standard 4″ backboxes and surface-mount enclosures where deeper units compete with conduit. At 10 lbs, one tech handles positioning and anchoring without assistance.

Deployment Considerations:

  • Confirm your total connected load budget before speccing output count — 16A total across 8 outputs averages 2A per circuit, which is comfortable for locks and readers but tight if any circuit drives a high-current gate operator or barrier arm.
  • The 115VAC / 60Hz input is North America-specific; international projects or sites with 230VAC infrastructure will need a step-down transformer or an alternate Altronix model configured for that input range.

The T2HW16Q is the right call for a commercial office or campus access control riser where you need a clean, factory-assembled power chassis with network-visible status and dual-voltage flexibility — specifically on projects where the alternative is field-wiring three separate components in a crowded IDF cabinet.

Specifications
Input Voltage: 115VAC, 60Hz
Output Voltage: 12VDC / 24VDC
Maximum Output Current: 16A
Number Of Outputs: 8
Dimensions: 13" x 12" x 3.5"
Weight: 10 lbs
Q&A
Reviews
Have Questions?

Altronix TROVE2HW2/THWD2/24V@10A/LINQ - T2HW16Q

$3,005.14
$1,833.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources