Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Altronix T2RM7CK1D Rack-Mount Access Control Power Supply with Form C Relays

Overview

The Altronix T2RM7CK1D is a rack-mount power supply and relay module engineered for commercial access control and surveillance infrastructure. Designed to slot into the T2RM7F8SD pre-wired rack enclosure, this unit delivers 12VDC or 24VDC at 6A continuous — enough sustained output to power multiple door controllers, electrified hardware, or field devices without derating under load. If you're building or expanding a centralized power distribution rack for an enterprise access control system, the T2RM7CK1D is the core power module that anchors that infrastructure.

UL Listed and CE marked, the T2RM7CK1D draws 120VAC/60Hz at up to 4.5A input and converts to regulated DC output suitable for a wide range of access control peripherals. A 6.3A/250V input fuse protects upstream wiring and the transformer — a straightforward overcurrent safeguard that simplifies commissioning and AHJ inspections.

Key Features

  • 6A Continuous DC Output at 12VDC or 24VDC: The selectable output voltage means you can match the supply to the specific door hardware on a given run — 12VDC for most electric strikes and mag-locks, 24VDC for higher-voltage locking hardware — without sourcing a separate supply per voltage tier.
  • Form C Relay Outputs (28VAC or VDC @ 2.5A): Onboard Form C relays rated at 28VAC or VDC at 2.5A give you normally-open and normally-closed control contacts directly at the rack. This means door-strike switching or alarm integration can be wired to the module rather than run back to a distant panel — a real wiring economy on multi-door deployments.
  • PTC-Protected Outputs at 2.5A: Positive temperature coefficient (PTC) resettable overcurrent protection on outputs eliminates the need to manually replace blown fuses on individual device runs. A shorted field device trips the PTC; once the fault clears, the output self-resets. This matters on large sites where tracking down a blown fuse per door can consume hours of tech time.
  • 1A Unswitched Auxiliary Output: The auxiliary 1A output runs continuously, independent of relay state — purpose-built for powering controllers or readers that must stay live regardless of the relay's position. Wire your access controller here; the relay handles the locking hardware.
  • UL Listed and CE Certified: UL Listing means this unit has been independently tested to recognized safety standards — relevant for installations in jurisdictions where AHJs require listed equipment, or wherever your security spec requires UL-compliant power sources. CE marking covers European conformity for cross-border or international deployments.
  • 0°C to 49°C Operating Range: The specified operating temperature accommodates standard IT room and telecommunications closet environments. The 49°C upper limit is practical for equipment rooms without precision cooling — not a cold-storage or outdoor-rated unit, but solid for typical IDF closets and centralized head-end rooms.
  • 123 BTU/Hr. Heat Dissipation: At 123 BTU/Hr., you'll need to account for this unit's thermal contribution in a populated rack. In a fully loaded multi-module enclosure, aggregate BTU output drives ventilation decisions — factor this number into your rack thermal budget before finalizing the enclosure layout.
  • Lifetime Manufacturer Warranty: Altronix backs the T2RM7CK1D with a lifetime warranty — meaningful for infrastructure-grade power equipment that's expected to outlast the devices it powers by a significant margin.

Integration and Compatibility

The T2RM7CK1D is engineered to install directly into the Altronix T2RM7F8SD pre-wired rack enclosure, which handles the backplane interconnects and reduces field wiring labor substantially. The 19.0

Specifications
Input Voltage: 120VAC, 60Hz
Input Current: 4.5A max
Output Voltage: 12VDC / 24VDC
Output Current: 6A continuous
Auxiliary Current: 1A (unswitched)
Input Fuse: 6.3A/250V
PTC Outputs: 2.5A
Form C Relays: 28VAC or VDC @ 2.5A
Dimensions: 3.25" x 19.0" x 33.1"
Shipping Dimensions: 7.75" x 22.5" x 42.0"
Weight: 40.5 lb.
Shipping Weight: 45.5 lb.
Operating Temperature: 0ºC to 49ºC
Storage Temperature: -20ºC to 70ºC
Relative Humidity: 85% +/- 5%
BTU/Hr: 123 BTU/Hr.
Agency Listings: UL Listed, CE European Conformity
Warranty: Lifetime Warranty
Q&A
Reviews
Have Questions?

Altronix T2RM7F8SD PRE-WIRED - T2RM7CK1D

$3,634.81
$2,220.99

RELATED PRODUCTS

Save $1,112.45
Altronix T2RM7CK1DQ Pre-Wired Power Supply/Charger
Add to Cart The item has been added

Altronix T2RM7CK1DQ

Altronix T2RM7CK1DQ Pre-Wired Power Supply/Charger

Pre-wired power supply and charger for access control and alarm systems

  • Factory pre-wired for plug-and-play installation, eliminating field wiring errors.
  • Integrated battery charger provides built-in backup power support within a single unit.
  • Rack-mount form factor with lifetime warranty suits long-term access control deployments.
Usually Ships in 2-3 Weeks Free shipping over $499
$3,484.44 $2,371.99 Save $1,112.45
The item has been added Add to quote
$3,484.44 $2,371.99 Save $1,112.45
Save $1,112.45 Add to cart Add to quote

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources