Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C3W36RL-0AJE2MT4 0U Switched PDU with Per-Outlet Power Sensing
The Server Technology C3W36RL-0AJE2MT4 is a 0U vertical switched PDU built for data center racks and network closets where you need individual outlet control and real per-outlet power data without eating rack unit space. It carries 36 total outlets in a RAMLOCK HDOT layout — 18 C13 and 18 CX receptacles — on a 70-inch strip that mounts in the rear channel of the rack, leaving your 1U/2U slots for compute and network gear. This is a PIPS unit (Per-Inlet Power Sensing plus per-outlet switching and metering), so you get outlet-level on/off control and outlet-level power readings, not just a single input reading for the whole strip.
Overview
C3W36RL-0AJE2MT4 accepts 120V, 208V, 230V, or 240V input at 50/60Hz through an IEC C20 inlet, with rated input current of 16A (up to 20A on North American branch circuits) and a global input power capacity of 3.6kW (3.8kW in North America). The branch circuit breaker is rated at 16A with 10kAIC interrupt rating in North America and 5kAIC for rest-of-world installs, which sets the real ceiling for how much load you can safely stack across the outlet groups before tripping.
Key Features
- RAMLOCK HDOT outlets (18 C13 + 18 CX): RAMLOCK physically locks power cords in place, so a technician yanking a cable during rack service doesn't accidentally drop power to a neighboring server — a real concern on dense 0U strips where cords run close together.
- Per-outlet switching and metering (PIPS): each of the 36 outlets can be switched and read independently, so you can remote-cycle a hung server or measure exactly which device is driving your circuit toward the 16A branch breaker limit instead of guessing across a shared reading.
- C13 outlets rated ≤12A @ 120-240V (NA) / ≤10A @ 220-230V (global): sized for standard server and switch power supplies — check nameplate draw against this ceiling when planning outlet assignment.
- CX outlets rated ≤16A @ 120-240V (NA and global): the CX form factor accepts a broader mix of cord types at higher per-outlet current, useful for higher-draw equipment sharing the same strip as lighter C13 loads.
- Dual Gigabit Ethernet ports (10/100/1000 Mbps): gives you a redundant or daisy-chain-friendly network path for remote management — useful when the PDU sits in a rack where a single NIC failure shouldn't cut off visibility.
- Daisy chain up to 16 PDUs: a whole row of racks can be managed and monitored from a single network drop instead of running Ethernet to every strip, which cuts switch port consumption in multi-rack deployments.
- 802.11 a/b/g/n WiFi: lets you reach initial configuration or perform diagnostics without pulling a network cable to a PDU buried in a dense cabinet.
- Quiescent power draw under 10W: the switching and metering electronics themselves barely register against your capacity planning, so the PDU's own overhead won't eat into the 3.6-3.8kW you're budgeting for IT load.
- Measurement accuracy ±1% on voltage, current, active power, apparent power, and energy (±3% power factor): accurate enough to trust for capacity planning and billback/chargeback calculations rather than rough estimates.
- Protocol support — HTTP/HTTPS, TLSv1.2, SSHv2, SNMPv2c/v3, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP, IPv4/IPv6: integrates with existing DCIM and network monitoring stacks and supports centralized authentication instead of local-only accounts.
- Operating range 0°C to 60°C, 8-90% RH non-condensing, up to 6,500ft elevation: rated for standard data center halls as well as warmer edge closets or elevated-altitude facilities without derating concerns inside that envelope.
- cTUVus and FCC Part 15 Class A certified (NA); TUV T-Mark, CE, RoHS, WEEE (global): covers both North American and international deployment paperwork for facilities that need documented compliance on file.
Integration & Compatibility
Console access is via RJ45, with an additional RJ45 sensor port for environmental monitoring probes and a 6P6C aux port for expansion accessories. A USB-A and USB-B pair round out local connectivity for firmware updates or direct configuration. The C3W36RL-0AJE2MT4 (often searched as C3W36RL 0AJE2MT4) fits into network video recorder and server rack deployments where surveillance infrastructure shares cabinet space with switching gear — pair it with a PoE switch lineup for camera drops and consult a PoE planning guide when budgeting combined IT and camera load across a rack. Browse the full Server Technology catalog for companion 0U and horizontal PDU models, and see the broader power distribution units category for rack-height alternatives if 0U vertical mounting doesn't fit your cabinet.
Frequently Asked Questions
Q: How many outlets does the C3W36RL-0AJE2MT4 have?
A: 36 total — 18 C13 and 18 CX receptacles in a RAMLOCK HDOT outlet layout, individually switched and metered.
Q: What input voltage does the C3W36RL-0AJE2MT4 support?
A: 120V, 208V, 230V, or 240V at 50/60Hz through an IEC C20 inlet, with a global input power capacity of 3.6kW (3.8kW in North America).
Q: Can outlets on the C3W36RL-0AJE2MT4 be controlled individually?
A: Yes — this is a PIPS (Per-Inlet Power Sensing) unit with per-outlet switching and metering across all 36 outlets.
Q: How many PDUs can be daisy-chained together for management?
A: Up to 16 PDUs can be daisy-chained on a single network connection.
Q: What network management protocols does the C3W36RL-0AJE2MT4 support?
A: HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, and FTP/SFTP, along with dual Gigabit Ethernet ports and 802.11 a/b/g/n WiFi.
Q: What is the operating temperature range?
A: 0°C to 60°C with 8%RH to 90%RH non-condensing humidity, rated to 6,500ft elevation.

The outlet count is what jumps out on the C3W36RL-0AJE2MT4 — 36 total across 18 C13 and 18 CX, all individually switched. That's a meaningful outlet density for a single 0U strip, and it changes how you plan a rack elevation.
Technical Highlights:
- Per-outlet metering at ±1% accuracy: on a strip with 36 loads sharing a 16A branch breaker, knowing exactly which outlet is drawing what matters more than an aggregate reading — you can rebalance load before you trip a breaker instead of after.
- 16A branch breaker with 10kAIC (NA) interrupt rating: that's your real capacity ceiling regardless of the 3.8kW North American power capacity figure — plan outlet assignment against the breaker, not just the headline wattage.
- Dual GbE plus 16-unit daisy chain: a row of C3W36RL-0AJE2MT4 units can share management traffic on one network drop, which matters when you're deploying multiple 0U strips across adjacent racks and don't want to burn a switch port per PDU.
Deployment Considerations:
- RAMLOCK outlets add a physical cord-retention step during install — budget a little extra time per cord versus a standard IEC receptacle, but it pays off the first time someone brushes a cord during hot-aisle work.
- The C13/CX current ratings differ (12A NA vs 16A NA per outlet) — don't assume uniform per-outlet capacity when spec'ing equipment placement across the strip.
This is a strong fit for a colo or enterprise data center row standardizing on 0U vertical PDUs with per-outlet visibility for chargeback reporting, particularly where mixed C13/C14 and CX cord equipment shares the same cabinet.
Compare with similar
Server Technology Switched PRO3X With Pips 0U - C3W36RL-0AJE2MT4
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology