Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology STV-4523C Switched 0U Rack PDU with Per-Inlet Power Sensing
Overview
The STV-4523C is a 0U vertical switched PDU from the PRO2 line, built for data center racks that need outlet-level control plus real per-inlet metering rather than a single aggregate reading. It ships with 48x IEC C13 outlets on a single 415V Wye input, rated for 11.5kW at 16A, and is designed to mount in the rear rail space of a cabinet without consuming any U space usable for servers or network gear. If you're populating a high-density rack and need both remote outlet cycling and branch-level current visibility on one strip, the STV-4523C is built for exactly that job.
Key Features
- Per-Inlet Power Sensing (PIPS): Monitors current (A), voltage (V), power (W), apparent power (VA), crest factor, power factor, and energy at the inlet — ±1% accuracy on current, voltage, active power, and apparent power. That level of precision matters when you're billing colocation tenants or validating capacity planning against actual draw instead of nameplate estimates.
- 48x IEC C13 Outlet Control: Switch power to individual outlets or groups from the network interface — reboot a hung server remotely instead of walking the data center floor, or power down unused receptacles to cut idle draw.
- Branch Circuit Protection (UL489): 1-pole, 20A magnetic-hydraulic breakers protect each branch and meet the UL/IEC 62368-1 branch circuit protection requirement — a breaker trips locally on an overload instead of taking down the whole PDU.
- Branch Current Monitoring with SNMP Alerts: Tracks current at each breaker branch and fires SNMP-based alerts and emails before a branch trips — useful when you're load-balancing across three phases in a dense cabinet and want a warning before a breaker opens mid-shift.
- Auto-Flip LED Current Display: Three LEDs cycle per-phase current readings at the unit itself, so a tech standing at the rack can check load balance without pulling up the web interface.
- Hot-Swap Network Card with Star Multi-Linking: PRO2 links up to four power circuits under one IP address, and the Expansion unit keeps network access alive if the Primary loses power — a single management IP covers the whole linked group instead of four separate logins.
- 415V Wye 3P+N+G Input, 20A IEC 60309: Matches standard European/international 3-phase distribution and delivers 11.5kW of usable capacity to the strip — sized for dense server or switch rows where a single-phase PDU would run out of headroom.
- Ethernet 10/100/1000 Mbps + RS-232 Serial: Manage over HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, or LDAP(S) — fits into an existing out-of-band management network without a proprietary tool.
- Temperature/Humidity Probe Support: Connects two external 10' (3m) T/H probes with SNMP alerting — extends environmental monitoring to the rack itself, not just the room-level CRAC sensor.
- Wide Operating Range: Rated 0°C to 60°C and 8–90% RH operating, with storage down to -40°C — the 60°C ceiling gives headroom in hot aisles or edge enclosures that run warmer than a standard data hall.
- High-Retention Locking Outlets: C13 receptacles are compatible with P-Lock type power cords for higher retention — worth specifying if the rack sees vibration or frequent cable moves and standard C14 cords have worked loose before.
Integration & Compatibility
At 69.0in x 3.25in x 2.25in, the STV-4523C mounts vertically in 0U rear-rail space, keeping all 48 outlets accessible without displacing any front-facing rack units. It pairs naturally with network video recorders or dense switch stacks where per-device power cycling saves a truck roll, and fits into broader PDU and power distribution planning for a cabinet. For guidance on sizing PDU capacity and outlet count against a planned rack load, see the internal PoE and power planning guide. Server Technology's PDU catalog includes higher-density and lower-outlet-count variants within the PRO2 and PRO3X lines if 48 outlets is more or less than the deployment calls for. STV-4523C (often searched as STV 4523C) integrates over standard SNMP MIBs, so it drops into existing DCIM and network monitoring tooling without a proprietary agent.
Frequently Asked Questions
Q: How many outlets does the STV-4523C have and what type?
A: 48x IEC C13 outlets on a single 0U vertical strip.
Q: What input power does the STV-4523C require?
A: 240/415V Wye, 3P+N+G, 20A via IEC 60309 6Hr connector, rated 16A input current and 11.5kW capacity.
Q: Does the STV-4523C monitor power at each inlet or just the whole unit?
A: It uses Per-Inlet Power Sensing (PIPS), measuring current, voltage, power, apparent power, crest factor, power factor, and energy at each inlet, with ±1% accuracy on current, voltage, and active/apparent power.
Q: Can I remotely reboot individual servers connected to the STV-4523C?
A: Yes — it's a switched PDU, so outlets or outlet groups can be cycled remotely to reboot connected equipment.
Q: What management protocols does the STV-4523C support?
A: HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), and RS-232 serial, over a 10/100/1000 Mbps Ethernet interface.
Q: What's the operating temperature range for the STV-4523C?
A: 0°C to 60°C operating, with 8%RH to 90%RH humidity; storage range is -40°C to 85°C.

What stands out on the STV-4523C is the ±1% measurement accuracy on inlet current, voltage, and active/apparent power — that's PIPS doing real per-inlet metering, not a single averaged reading pushed across 48 outlets. On a strip this dense, that precision is the difference between guessing at branch load and actually knowing it.
Technical Highlights:
- 11.5kW at 16A on 415V Wye: Sized for a 3-phase feed, giving real headroom over a single-phase 208V strip in the same footprint — worth checking against your panel's available 3P+N+G capacity before ordering.
- UL489 branch circuit breakers, 1-pole 20A: Each branch trips independently on overload, so one overloaded group of outlets doesn't take the whole 48-outlet strip down.
- Branch current monitoring with SNMP alerting: Flags high branch usage before a breaker trips — set thresholds early if you're balancing load across phases in a dense cabinet.
Deployment Considerations:
- This is a 0U vertical unit at 69.0in x 3.25in x 2.25in — plan rear rail clearance in the cabinet before ordering, since it doesn't consume front U space but does need depth.
- The IEC 60309 3P+N+G input plug requires a matching 415V Wye receptacle — confirm your facility's panel wiring supports this before specifying the STV-4523C over a 208V single-phase alternative.
The STV-4523C fits a colocation or hyperscale row where tenants are billed on measured draw and operators need branch-level alerting ahead of a trip — 48 C13 outlets on one 3-phase drop covers a fully populated server row without a second PDU.
Compare with similar
Server Technology Switched PRO2 W/ Pips (per Inlet - STV-4523C
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology