Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology C2W36TE-4NAE2M99 Switched 3-Phase Rack PDU

Overview

The Server Technology C2W36TE-4NAE2M99 is a switched 3-phase power distribution unit built for data center and network closet racks that need remote outlet control across a high-density load. This PRO2 series unit (C2W36TE-4NAE2M99, often searched as C2W36TE 4NAE2M99) delivers 36 switched outlets on a 60A, 3-phase input, giving you per-outlet on/off/reboot control from a rack that would otherwise depend on someone walking the aisle to power-cycle a hung server or switch.

Key Features

  • 36 Switched Outlets: Each outlet is independently controllable, so you can power-cycle a single hung device without touching anything else on the rack — a real time-saver during off-hours remote troubleshooting.
  • 60A, 3-Phase Input: High-amperage 3-phase feed supports dense server and networking loads on a single PDU, cutting down on the number of circuits and PDUs needed per rack.
  • 120V AC Output: Standard output voltage keeps the unit compatible with common IT and networking gear without step-down conversion.
  • Configurable Alternating Phase Outlet Layout: Outlets alternate across phases along the unit body, which helps balance load distribution across all three phases instead of stacking draw on one leg.
  • 0U Vertical Rack Height: Mounts vertically along the side of the rack rather than consuming horizontal rack unit space — with 36 outlets to place, that 0U footprint keeps your front-of-rack space free for actual compute and network gear.
  • 10ft Cord Length: Long enough to route to a subpanel or PDU whip without an extension, reducing the connection-point count that can introduce a loose-connector failure.
  • HDOT Cx Outlet Technology: Server Technology's HDOT (High Density Outlet Technology) design is built into this outlet configuration to support dense outlet spacing without physical interference between adjacent plugs on a fully populated PDU.
  • Rack-Mount Form Factor: Purpose-built for standard rack rail or vertical mounting channels, so it integrates into existing rack infrastructure without custom brackets.

Integration & Compatibility

As a switched PDU, the C2W36TE-4NAE2M99 is intended for environments already running remote power management — pairing it into your existing network video recorders or server rack infrastructure lets you extend outlet-level control to camera and recording equipment racks, not just compute racks. If you're planning capacity across a multi-rack deployment, review a PoE and power planning guide before finalizing circuit counts, since 3-phase 60A units like this one are typically specified per-rack rather than per-device. For racks holding IP cameras and recording appliances that need clean, monitored power alongside compute gear, a switched Server Technology PDU is a common pairing with a rack-mount PoE network switch to centralize both data and power management in one enclosure.

Frequently Asked Questions

Q: How many outlets does the C2W36TE-4NAE2M99 have?

A: It has 36 switched outlets, each independently controllable.

Q: What input power does this PDU require?

A: It requires a 3-phase, 60A input circuit.

Q: What output voltage does the C2W36TE-4NAE2M99 provide?

A: Output is 120V AC.

Q: Is this a vertical or horizontal rack-mount unit?

A: It mounts vertically and has a 0U rack height, so it does not consume horizontal rack unit space.

Q: How long is the power cord on the C2W36TE-4NAE2M99?

A: The unit ships with a 10ft cord.

Karl Wilson
Karl Wilson

The C2W36TE-4NAE2M99 is the PDU I point people to when they've got a rack full of 1U/2U gear and no clean way to power-cycle a single unit at 2am. 36 switched outlets on a 60A 3-phase input is a lot of density, and it's built to be managed remotely — not just plugged in and forgotten.

Technical Highlights:

  • 60A 3-Phase Input: Feeds all 36 outlets from one circuit, so you're not running multiple single-phase PDUs to cover the same rack load.
  • 36 Independently Switched Outlets: Reboot one stuck device without cutting power to the other 35 — this is the entire value proposition over a basic PDU.
  • 0U Vertical Mount: Runs the full height of the rack along the side rail, so you keep every horizontal U for servers and switches instead of the PDU itself.

Deployment Considerations:

  • Confirm your electrical infrastructure actually terminates in a 3-phase 60A feed before specifying this unit — it's not a drop-in replacement for a single-phase PDU.
  • The alternating phase outlet layout is meant to help balance load across all three phases, but you still need to plan which devices land on which outlets to avoid stacking draw on one leg.

This is the right call for a colo cage or dedicated network closet consolidating a high-density rack onto one 3-phase circuit with full remote outlet control — not for a small office rack running on a standard 120V single-phase drop.

Specifications
Input Phase: 3-Phase
Number Of Outlets: 36-Outlets
Input Current: 60A
Cord Length: 10ft
Rack Height: 0U
Output Voltage: 120V AC
Mounting Orientation: Vertical
Form Factor: Rack-mount
Brand: Server Technology
MPN: C2W36TE-4NAE2M99
Type: Power Cord
Connectivity: PoE
Power: 120V AC
Q&A
Reviews

Server Technology Switched Primary PRO2 (36) - C2W36TE-4NAE2M99

$3,061.50
$2,921.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources