Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology C3WG36RL-EPJE2MT4 0U Switched Rack PDU with Per-Outlet Power Sensing

Overview

The Server Technology C3WG36RL-EPJE2MT4 is a 0U vertical switched PDU built for data center and network closet racks where you need outlet-level control and real power visibility, not just a branch-circuit amp reading. It's a POPS PRO3X unit with PIPS (Per-Inlet Power Sensing), running 36 HDOT (High Density Outlet Technology) outlets — 18 C13 and 18 Cx combo outlets — off a single 230V, 32A IEC input. If you're managing racks where remote reboot capability and outlet-level load data actually matter to your uptime SLA, this is the class of PDU to be looking at.

Key Features

  • 230V/32A input at 7.3kW capacity: a single IEC 230V/32A 2P+PE 6Hr plug feeds the whole unit, giving you real headroom for dense 1U/2U server and switch loads without needing a second circuit run.
  • 36 HDOT outlets (18 C13 + 18 Cx): the Cx combo outlets accept either C14 or C20 plugs, so you're not stuck re-ordering cords when a device shows up with the wrong connector — useful in mixed-vendor racks.
  • Per-outlet switching and sensing: remotely cycle power to a hung server or switch without a truck roll, and pull load data outlet-by-outlet instead of guessing which device is dragging the circuit.
  • PIPS (Per-Inlet Power Sensing): input current measured to ±10% at 0.1A (0.3–9.9A range) and input voltage to ±1% at 0.1V — tight enough to catch a drifting supply before it trips the 20A branch breaker.
  • Output measurement accuracy ±1% (0.01A current, 0.1V voltage): outlet-level readings precise enough to trust for capacity planning, not just rough load balancing.
  • 20A branch circuit breakers, rated 10 kAIC (North America) / 5 kAIC (ROW): breakers sized to protect downstream equipment and sized for the fault-current environment they're actually installed in.
  • Dual Gigabit Ethernet (2x 10/100/1000 Mbps): redundant network paths for management, so a single switch port failure doesn't take your PDU monitoring offline.
  • Master linking up to 16 PDUs: daisy-chain up to 16 units under one IP address, cutting down on the number of management endpoints you have to track in a large row.
  • Broad management protocol support (HTTPS, SSHv2, SNMPv2c/v3, LDAPv3/LDAPS, TACACS+, RADIUS, SFTP): integrates with existing enterprise auth infrastructure instead of forcing local-only accounts.
  • Quiescent power draw under 10W: the PDU's own overhead is negligible against a 7.3kW capacity — it isn't eating into your usable load budget.
  • Operating range 0°C to 60°C, 8–90%RH non-condensing: rated for unconditioned network closets and edge sites, not just climate-controlled data halls.
  • Console, USB-A/USB-B, and RJ45 sensor/aux ports: local CLI access and environmental sensor support (temperature/humidity probes) without extra hardware.

Integration & Compatibility

The C3WG36RL-EPJE2MT4 runs IPv4/IPv6 with HTTP/HTTPS, Telnet, and SNMPv2c/v3, so it drops into existing DCIM and network monitoring tooling without a proprietary management layer. TUV T-Mark, EMC EN55024/EN55032, CE, RoHS, and WEEE certifications support deployment across regulated commercial and EU-market environments. Physically it's a tall, narrow unit — 70.0in x 2.2in x 2.5in — designed to mount vertically in the rear channel of a rack, so confirm your cabinet's vertical PDU mounting rail clearance before ordering. For broader rack power planning, review a PDU and power planning guide alongside your network video recorders or server loads. Pair it with compatible rack mounts and cabinets to complete the vertical 0U installation, and browse the full Server Technology catalog for companion horizontal or basic PDU models in the same outlet family. If you're standardizing rack infrastructure across a build-out, the power distribution units category is the place to compare 0U switched models against basic and metered alternatives.

Frequently Asked Questions

Q: What's the input voltage and current on the C3WG36RL-EPJE2MT4?

A: It runs on 230V input at 32A rated current, delivered through an IEC 230V/32A 2P+PE 6Hr plug, for a total input power capacity of 7.3kW.

Q: How many outlets does the C3WG36RL-EPJE2MT4 have and what type?

A: 36 total HDOT outlets — 18 C13 outlets rated 10A @230V L-N, and 18 Cx combo outlets rated 16A @230V L-N.

Q: Can multiple C3WG36RL-EPJE2MT4 units be managed together?

A: Yes. Master linking supports up to 16 PDUs chained together under unified management.

Q: What's the operating temperature range?

A: 0°C to 60°C with 8%RH to 90%RH non-condensing humidity, rated for both climate-controlled and unconditioned installation environments.

Q: What's the warranty on the C3WG36RL-EPJE2MT4?

A: It carries a 2-year limited manufacturer warranty.

Q: What management protocols does the C3WG36RL-EPJE2MT4 support?

A: HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, and FTP/SFTP.

Eden Phillips
Eden Phillips

What stands out on the C3WG36RL-EPJE2MT4 is the output measurement accuracy — ±1% at 0.01A on current and ±1% at 0.1V on voltage, per outlet. That's precise enough to build real capacity-planning models off, not just trip alarms after the fact.

Technical Highlights:

  • 7.3kW input capacity at 32A/230V: enough headroom for a fully populated rack of 1U/2U compute without derating concerns on a single feed.
  • 18 C13 + 18 Cx outlet mix: the Cx combo outlets accepting both C14 and C20 plugs mean fewer cord-compatibility surprises when racking mixed-vendor gear.
  • PIPS input accuracy ±10% at 0.1A (0.3-9.9A range): tight enough resolution on the inlet side to catch load drift before it approaches the 20A branch breaker threshold.

Deployment Considerations:

  • This is a 0U vertical unit at 70.0in tall by only 2.2in wide — it mounts in the rear vertical channel, so measure that clearance before it ships, not after.
  • The 10 kAIC North America / 5 kAIC ROW breaker interrupt rating differs by region — confirm which fault-current rating applies to your install location before specifying.

This is the right PDU for a colo or enterprise data hall running mixed C13/C20 gear off a single 230V circuit, where outlet-level switching and PIPS-grade metering are part of the actual operational workflow — not a checkbox spec on the C3WG36RL-EPJE2MT4 (often searched as C3WG36RL EPJE2MT4) datasheet.

Specifications
Input Voltage: 230V
Frequency: 50/60 Hz
Input Plug: IEC 230V/32A 2P+PE 6Hr
Input Current: 32A
Input Current Rated: 32A
Input Power Capacity: 7.3 kW
Outlet C13 Rating: 10A @230V L-N
Outlet Cx Rating: 16A @230V L-N
Branch Circuit Breaker Rating: 20A
Branch Interrupt Rating: 10 kAIC (North America) / 5 kAIC (ROW)
Dimensions: 70.0in tall x 2.2in wide x 2.5in deep
Operating Temperature: 0°C to 60°C
Operating Humidity: 8%RH to 90%RH non-condensing
Storage Temperature: -40°C to 85°C
Storage Humidity: 8%RH to 90%RH non-condensing
Quiescent Power Draw: < 10W
Ethernet Ports: 2 x 10/100/1000 Mbps
Sensor Port: 1 x RJ45
Aux Port: 1 x 6P6C
Console Port: 1 x RJ45
USB Ports: 1 x USB-A, 1 x USB-B
Protocols: HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP
Certifications: TUV T-Mark, EMC EN55024/EN55032, CE, RoHS, WEEE
Input Current Measurement Accuracy: ± 10% at 0.1 amp (0.3 - 9.9 amps)
Input Voltage Measurement Accuracy: ± 1% at 0.1 volt
Output Current Measurement Accuracy: ± 1% at 0.01 amp
Output Voltage Measurement Accuracy: ± 1% at 0.1 volt
Master Linking: Max 16 PDUs
Operating Temperature Rating: 60°C
Warranty: 2-year limited
Brand: Server Technology
MPN: C3WG36RL-EPJE2MT4
Type: Network Switch
Connectivity: USB
Power: 10W
Q&A
Reviews

Server Technology Switched Pops PRO3X With - C3WG36RL-EPJE2MT4

$2,744.00
$2,619.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources