Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology C3WG36RL-2BJE2MT4 Switched 0U Rack PDU

Overview

The Server Technology C3WG36RL-2BJE2MT4 is a switched 0U rack power distribution unit built for data center and telecom cabinets that need granular, remote outlet control without giving up rack unit space for compute or network gear. As a 0U vertical mount, it runs the full height of the rack in the side channel, freeing every horizontal rack unit for servers, switches, and patch panels — a real consideration when cabinet space is already tight. This is a switched PDU, meaning each outlet can be turned on or off remotely, which matters for anyone managing racks that need scheduled reboots, sequenced startup, or the ability to kill power to a hung device without a truck roll. The C3WG36RL-2BJE2MT4 (often searched as C3WG36RL 2BJE2MT4) is part of the Server Technology catalog of switched and monitored PDUs used across enterprise and colocation environments.

Key Features

  • 36 RamLock HDOT outlets (18 C13 + 18 Cx): the mixed outlet configuration covers standard IEC C14 server power cords on the C13 side while the Cx outlets accept either C14 or C20 plugs — useful when a single cabinet mixes 1U servers with higher-draw switches or blade chassis on the same strip.
  • RamLock outlet retention: each outlet mechanically locks the power cord in place, which cuts down on accidental unplugging in dense cabinets where cable routing gets crowded — a common failure point during rack moves or cable audits.
  • Switched, per-outlet control: remotely cycle power on individual outlets, so a locked-up device gets a hard reboot without walking the data center floor or waiting on a hands-and-eyes ticket.
  • Color Matrix LCD display: local readout at the rack for load and status information, so a technician standing at the cabinet doesn't need a laptop and network access just to check whether a circuit is near capacity.
  • 208V, 1-Phase, 30A input: matches standard high-density data center circuit provisioning — confirm your cabinet's whip and breaker match this rating before ordering, since a 30A/208V circuit is not interchangeable with a 20A or 3-phase feed.
  • NEMA L6-20P input connector: a twist-lock plug that resists accidental disconnection under cable strain, which matters on a PDU carrying load for an entire cabinet.
  • 9.5 ft (2.9 m) power cord: long enough to reach overhead or underfloor whips in most cabinet layouts without an extension, reducing the odds of a mid-project surprise on cord reach.
  • Dual 10/100/1000 Mbps Ethernet: gigabit-capable dual network ports support redundant network paths or daisy-chained management, so you're not left without visibility if one network link drops.
  • Raritan DX2 sensor support: connects to Raritan's DX2 environmental sensor line for temperature, humidity, or contact-closure monitoring at the rack, extending visibility beyond power alone into rack-level environmental conditions.
  • Circuit breaker protection: built-in breakers protect against overload conditions on the strip itself, which helps contain a fault to one PDU rather than tripping an upstream panel breaker and taking down the whole row.

Integration & Compatibility

The dual Gigabit Ethernet interfaces on the C3WG36RL-2BJE2MT4 support standard IP-based management and monitoring workflows common in network power distribution units deployments, and the Raritan DX2 sensor compatibility means this PDU can feed into an existing environmental monitoring layer rather than requiring a separate standalone sensor network. When planning a cabinet build-out, pair this PDU with a PDU and UPS upstream supply sized to the 208V/30A circuit, and review your power planning guide before finalizing circuit allocation across a row of cabinets — mixing switched PDU loads with existing UPS capacity is where under-provisioning most often shows up after the fact. Because this is a 0U vertical unit, confirm your cabinet's vertical channel depth and height before ordering, and check outlet count needs against actual device count: 36 outlets across 18 C13 and 18 Cx covers a wide mix of server and network gear, but high-draw single devices should be counted individually against the 30A circuit total.

What's in the Box

Package contents were not detailed in available manufacturer evidence for this listing.

Frequently Asked Questions

Q: What is the input voltage and amperage for the C3WG36RL-2BJE2MT4?

A: It's rated for 208V, single-phase, 30A input, delivered through a NEMA L6-20P twist-lock connector.

Q: How many outlets does the C3WG36RL-2BJE2MT4 have?

A: It has 36 total outlets using RamLock HDOT retention: 18 C13 outlets and 18 Cx (C13/C20) outlets.

Q: Is the C3WG36RL-2BJE2MT4 a switched or monitored-only PDU?

A: It's a switched PDU, meaning individual outlets can be turned on and off remotely, not just monitored for load.

Q: Does the C3WG36RL-2BJE2MT4 support environmental sensors?

A: Yes, it supports Raritan DX2 sensors for environmental monitoring at the rack.

Q: What network connectivity does the C3WG36RL-2BJE2MT4 offer for remote management?

A: It includes dual 10/100/1000 Mbps Ethernet ports for redundant or daisy-chained network management access.

Q: How long is the power cord on the C3WG36RL-2BJE2MT4?

A: The unit ships with a 9.5 ft (2.9 m) power cord terminating in a NEMA L6-20P plug.

Marty Allison
Marty Allison

What stands out on the C3WG36RL-2BJE2MT4 is the 36-outlet count split 18 C13 / 18 Cx on a single 0U strip — that's a lot of density packed into a vertical mount that doesn't eat rack units. If you're specing out a cabinet with a mixed server and switch load, this is the kind of PDU that lets you stop juggling two separate strips.

Technical Highlights:

  • 208V / 1-Phase / 30A input: matches high-density data center circuit provisioning — verify your whip and upstream breaker match before ordering since this isn't interchangeable with a 20A or 3-phase feed.
  • Dual 10/100/1000 Mbps Ethernet: gigabit-capable redundant network paths mean you're not blind to the PDU if one uplink fails, which matters when the PDU is your last line of remote-reboot capability.
  • RamLock HDOT retention on all 36 outlets: mechanical cord locking cuts down on the accidental unplugs that happen during cable audits in dense cabinets — a small detail that saves a truck roll.

Deployment Considerations:

  • This is a 0U vertical-mount unit, so measure your cabinet's vertical channel before ordering — it runs the full rack height in the side rail, not a horizontal rack unit slot.
  • The Cx outlets accept both C14 and C20 plugs, so count your higher-draw devices individually against the shared 30A circuit total rather than assuming all 36 outlets can run at once at full load.

This is the right strip for a colocation or enterprise cabinet mixing 1U servers with network switches on one circuit, where remote outlet-level power cycling and Raritan DX2 environmental visibility both need to live on the same unit.

Specifications
Rack Unit: 0U
Outlets: 36 RamLock HDOT; 18 C13; 18 Cx
Display: Color Matrix LCD
Voltage Phase Current: 208V; 1-Phase; 30A
Input Connector: NEMA L6-20P
Cord Length: 9.5 ft; 2.9 m
Network Interface: Dual 10/100/1000 Mbps Ethernet
Sensor Support: Raritan DX2
Protection: Circuit breakers
Brand: Server Technology
MPN: C3WG36RL-2BJE2MT4
Type: Power Cord
Connectivity: Ethernet
Product Type: Power Distribution Unit
Outlet Type 1: 18 C13
Outlet Type 2: 18 Cx
Voltage: 208V
Phase: 1-Phase
Current: 30A
Country of Origin: United States
UNSPSC: 39121017
Q&A
Reviews

Server Technology Switched Pops PRO3X With - C3WG36RL-2BJE2MT4

$2,744.00
$2,654.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources