Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology C2WG12SM-0AJA2D3 Switched Per-Outlet Metered Rack PDU

Overview

The Server Technology C2WG12SM-0AJA2D3 is a 1U switched rack PDU built for data center and network closet deployments where you need to know exactly what every outlet is drawing and be able to cycle power remotely without a truck roll. It's part of the PRO2 Switched POPS line, rated for 3.3kW at 208V through a single IEC C20 input, and it puts 12 HDOT Cx outlets on a 1U chassis measuring 1.75in x 17.2in x 11.57in — a compact footprint for cabinets where rack space is already fought over. C2WG12SM-0AJA2D3 (often searched as C2WG12SM 0AJA2D3) targets colocation racks, edge closets, and any environment where per-outlet visibility and remote switching matter more than raw outlet count.

Key Features

  • HDOT Cx Outlets (9x C13 + 3x C19): Cx is a UL-tested hybrid outlet that physically accepts both C14 and C20 plugs on the same receptacle. That means you're not stuck pre-planning which outlets take which cord type — a server with a C20 power supply and one with a C14 cord can sit side by side on the same strip without an adapter.
  • Per-Outlet Power Sensing (POPS): Each of the 12 outlets independently reports current, voltage, power, apparent power, crest factor, power factor, and energy. When a rack starts drawing more than expected, you can isolate which device is responsible instead of guessing from a single aggregate reading.
  • Per-Inlet Power Sensing (PIPS): The inlet itself is monitored the same way outlets are, giving you a check on total draw against the 16A input current rating and 3.3kW capacity before a breaker trips.
  • Branch Circuit Monitoring and Protection: The unit ships with 2-pole, 20A branch circuit breakers rated for 10 kAIC interrupt capacity, monitored individually with SNMP alerts on high usage — you get a warning before a branch trips instead of finding out when a rack goes dark.
  • Remote Outlet Control: Individual outlets can be switched on, off, or cycled remotely, which matters when a hung server needs a hard power cycle and the nearest hands are in a different building.
  • Auto-Flip Current Display: Onboard LEDs cycle through per-phase current readings, giving techs a fast visual load check during rack walks without pulling up the web interface.
  • Hot-Swap Network Card with Star Multi-Linking: PRO2 links up to four power circuits under a single IP address, and if the primary unit loses power, the linked expansion unit keeps the network card alive — you don't lose remote visibility just because one circuit dropped.
  • Temperature/Humidity Monitoring: Supports two external 10ft T/H probes per unit with SNMP alerts and email notification, useful for catching a failing CRAC unit before it becomes a thermal event across the row.
  • Wide Environmental Range: Rated for 0°C to 60°C operating temperature and 8%RH to 90%RH humidity, covering everything from a conditioned data hall to a less-controlled edge closet or telecom cabinet.
  • Multi-Protocol Network Management: Supports HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, and LDAP(S), plus an RS-232 serial interface and 10/100/1000 Mbps Ethernet — it fits into existing DCIM and monitoring stacks rather than forcing a proprietary tool.

Integration & Compatibility

Because the C2WG12SM-0AJA2D3 speaks SNMP and standard network protocols out of the box, it integrates into existing monitoring and DCIM platforms rather than requiring a dedicated management console. The RS-232 serial port covers out-of-band access for environments where a dedicated management network isn't available yet. LDAP(S) support means outlet-control access can tie into an existing directory service rather than maintaining a separate local user list on every PDU in the rack.

Frequently Asked Questions

Q: What's the input voltage and plug type on the C2WG12SM-0AJA2D3?

A: It runs on 208V input through an IEC C20 plug, rated for 16A input current and 3.3kW capacity.

Q: How many outlets does the C2WG12SM-0AJA2D3 have and what type?

A: 12 HDOT Cx outlets total — 9x C13 and 3x C19 — each accepting either C14 or C20 plugs.

Q: Can I monitor power at the individual outlet level?

A: Yes. Per-Outlet Power Sensing (POPS) reports current, voltage, power, apparent power, crest factor, power factor, and energy for each of the 12 outlets independently.

Q: What network protocols does this PDU support for remote management?

A: HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, and LDAP(S), plus an RS-232 serial interface and 10/100/1000 Mbps Ethernet.

Q: What's the operating temperature range?

A: 0°C to 60°C with 8%RH to 90%RH humidity, covering standard data center and less-controlled edge environments.

Q: Does the C2WG12SM-0AJA2D3 support remote outlet switching?

A: Yes, it's a switched PDU — individual outlets can be turned on, off, or cycled remotely, and outlet control access can be tied to LDAP(S) for centralized user management.

James Everett
James Everett

What stands out on the C2WG12SM-0AJA2D3 is the outlet mix — 9x C13 and 3x C19, all HDOT Cx, so you're not stuck reshuffling gear because a new server showed up with a C20 power cord. At 3.3kW on a 208V/16A input through the C20 inlet, this is sized for a single mixed-load cabinet, not a high-density GPU rack.

Technical Highlights:

  • Per-Outlet Power Sensing: All 12 outlets report current, voltage, power, VA, crest factor, power factor, and energy independently — when a rack's draw creeps up, you pull outlet-level data instead of guessing which device is the culprit.
  • Branch Circuit Breakers, 10 kAIC: 2-pole 20A breakers with a 10 kAIC interrupt rating monitored individually, with SNMP alerts before a branch trips — that's the difference between a warning email and an unplanned outage.
  • Star Multi-Linking: Up to four power circuits share one IP address, and the network card stays alive on the linked Expansion unit if the Primary loses power — you keep remote reach into the rack even during a partial circuit failure.

Deployment Considerations:

  • The 1.75in x 17.2in x 11.57in chassis is standard 1U, but confirm your cabinet has horizontal mounting space free — this isn't a zero-U vertical PDU, so it consumes rack unit space like any other 1U device.
  • Rated to 0°C-60°C and 8-90%RH, which covers most edge and telecom closets, but this is still a 208V/16A unit — verify your panel and circuit are provisioned for that before ordering, since it won't step down to 120V service.

This is the right unit for a colocation or edge cabinet running mixed C13/C19 gear off a single 208V circuit, where the operator wants per-outlet billing-grade data and the ability to remote-cycle a hung device without dispatching a technician.

Specifications
Outlet Type: HDOT Cx (C13/C19 Hybrid)
Number Of Outlets: 12
Input Voltage: 208V
Input Plug Type: IEC C20
Input Current Rated: 16A
Input Power Capacity: 3.3kW
Dimensions: 1.75in x 17.2in x 11.57in
Operating Temperature: 0°C to 60°C
Operating Humidity: 8%RH to 90%RH
Ethernet Speed: 10/100/1000 Mbps
Serial Interface: RS-232
Protocols: HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S)
Branch Circuit Breakers: 2-pole, 20A
Interrupt Rating: 10 kAIC
High Temperature Rating: 60°C
Brand: Server Technology
MPN: C2WG12SM-0AJA2D3
Type: Power Supply
Connectivity: RS-232
Q&A
Reviews

Server Technology Switched Pops PRO2 1U (12) - C2WG12SM-0AJA2D3

$1,845.00
$1,759.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources