Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2WG48TE-DQME2L99/C Switched 3-Phase Rack PDU
Overview
The Server Technology C2WG48TE-DQME2L99/C is a Switched POPS Primary PRO2 rack power distribution unit built for data center and network operations center environments where per-outlet control and phase balancing matter. This unit ships configured with 48 alternating-phase HDOT outlets on a 208V 3-phase input, giving you outlet-level switching across a full rack or a shared row of equipment. C2WG48TE-DQME2L99/C is the exact configuration code for this outlet count, voltage, and phase arrangement — worth confirming against your rack elevation before ordering, since Server Technology's PRO2 line ships in many outlet and voltage variants.
Key Features
- 48 Configurable Alt Phase HDOT Outlets: Outlets alternate phase assignment down the strip, so adjacent equipment draws from different phases automatically — this is what keeps a fully loaded rack from silently overloading one leg while the others sit idle.
- Switched Outlet Control: Each outlet can be power-cycled independently, which means a hung server or network appliance gets rebooted remotely instead of requiring a technician to walk the data center floor at 2am.
- 208V 3-Phase Input: Matches standard 3-phase data center distribution, letting you pull more total capacity through a single PDU chassis than a comparable single-phase unit — fewer PDUs per rack for the same load.
- PRIMARY PRO2 Platform: Server Technology's PRO2 controller architecture underlies the outlet switching and configuration on this unit, giving you a consistent management layer if you're standardizing on this PDU family across multiple racks.
Integration & Compatibility
Because C2WG48TE-DQME2L99/C is built on the PRO2 platform, it fits into deployments already standardized on Server Technology's switched PDU line — useful when your operations team wants one control interface across every rack in a row rather than mixing PDU brands and management tools. Confirm rack unit height and mounting orientation against your cabinet before install, since 48-outlet units on 3-phase input are typically vertical (zero-U) mount to fit outlet count without consuming rack space.
Frequently Asked Questions
Q: What voltage and phase does the C2WG48TE-DQME2L99/C run on?
A: It's built for 208V 3-phase input with 48 configurable alternating-phase HDOT outlets.
Q: Can individual outlets be switched on this PDU?
A: Yes — this is a Switched POPS Primary PRO2 unit, meaning each outlet can be controlled independently.
Q: What does 'Alt Phase' mean on the C2WG48TE-DQME2L99/C outlet configuration?
A: Outlets alternate across the three phases as you move down the strip, which helps balance load across all three legs of the 3-phase circuit instead of concentrating draw on one.
Q: Is the C2WG48TE-DQME2L99/C part of a larger PDU family?
A: Yes, it's built on Server Technology's PRIMARY PRO2 platform, which spans multiple outlet counts and voltage configurations.

The C2WG48TE-DQME2L99/C packs 48 outlets onto a single 208V 3-phase strip, and the alternating-phase HDOT layout is the detail I check first on any PRO2 order.
Technical Highlights:
- 48 Alt Phase HDOT Outlets: alternating phase assignment across all 48 outlets keeps load spread evenly across the 3-phase circuit instead of stacking draw on one leg.
- 208V 3-Phase Input: higher capacity per PDU chassis than single-phase, so fewer units are needed to cover a fully populated rack row.
- Switched Outlet Control: per-outlet power cycling on the PRO2 platform, useful for remote reboot of hung equipment without a floor visit.
Deployment Considerations:
- With 48 outlets on 3-phase input, plan for zero-U vertical mounting — this outlet count won't fit a horizontal rack-unit form factor.
- Confirm your upstream 3-phase 208V circuit and breaker sizing before ordering, since outlet count and phase configuration are fixed at the model level and not field-changeable.
This is the right call for a data center row standardizing on switched, phase-balanced power across densely populated 3-phase racks rather than a single-server closet running on standard single-phase circuits.
Compare with similar
Server Technology Switched Pops Primary - C2WG48TE-DQME2L99/C
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology