Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology C2WG48TE-DQME2M99 48-Outlet Switched 3-Phase PDU

The Server Technology C2WG48TE-DQME2M99 is a switched POPS Master Pro2 rack PDU built for data center and network operations center racks that need outlet-level control across a 208V 3-phase Delta feed. With 48 total outlets split across 30 C13 and 18 configurable high-current (Cx) positions, it targets mixed-load racks running servers, switches, and NVR/VMS infrastructure off a single vertical strip. This isn't a passive power strip — it's a managed PDU with per-outlet switching and metering, the kind of device an integrator specs when a customer needs remote power cycling on individual devices without walking the data hall.

Overview

This unit pulls 48A rated input current on a 208V Delta 60A IEC 60309 3P+G 9Hr plug, delivering 17.3 kW of input power capacity — enough headroom for a fully populated 42U rack of switching and recording gear with margin for future adds. At 80 inches tall and only 2.2 inches wide by 2.5 inches deep, it mounts as a zero-U vertical strip, meaning it doesn't consume rack unit space that would otherwise hold servers, NVRs, or patch panels. That's the deployment case for this form factor: racks where every U counts and power distribution has to disappear into the vertical rail.

Key Features

  • 48 total outlets (30x C13, 18x configurable Cx): C13 outlets rated up to 12A @ 208V L-L cover standard IEC C14 server and network gear power cords, while the 18 configurable high-current outlets (up to 16A @ 208V L-L) handle heavier draw devices like blade chassis or storage arrays on the same strip.
  • Outlet-level switching: Each outlet can be power-cycled independently over the network, so a hung NVR or switch gets rebooted remotely instead of requiring a data-center trip — a real time saver for remote or lights-out facilities.
  • Branch circuit breakers rated <= 16A, 10 kAIC interrupt rating: Individual branch protection isolates a fault to one circuit rather than tripping the whole PDU, so one overloaded outlet group doesn't take down the entire rack.
  • Input/output/branch measurement accuracy of +/-1% to +/-3%: Voltage and current readings accurate to +/-1% at the input and output level (+/-3% at the branch) give real load data for capacity planning instead of rough estimates — useful when you're deciding if a rack has room for one more device.
  • Quiescent power draw under 10W: The PDU's own overhead is negligible against a 17.3 kW capacity, so monitoring and switching intelligence doesn't meaningfully eat into your power budget.
  • Gigabit Ethernet management (10/100/1000 Mbps): Full-speed network connectivity supports responsive remote monitoring dashboards and firmware updates without a slow management link becoming the bottleneck.
  • Broad protocol support (HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP): This range of protocols means the PDU integrates into existing enterprise authentication (LDAP, TACACS+, RADIUS) and monitoring (SNMP) infrastructure rather than requiring a standalone management silo.
  • Operating range 0°C to 60°C, 8-90% RH: Rated for non-climate-controlled or marginal cooling environments — telecom closets and edge data rooms that run hotter than a tier-3 data center — without derating concerns inside that window.
  • UL 62368-1 / CSA C22.2 No. 62368-1 safety, FCC Part 15 Class A / CAN ICES-003 Class A EMC: North American safety and emissions certification supports use in commercial and industrial facilities where inspectors check for listed equipment.

Integration & Compatibility

The C2WG48TE-DQME2M99 (often searched as C2WG48TE DQME2M99) fits into the same racks as the network video recorders and switching gear covered in this catalog's network video recorders and network switches lines — a common pairing when a surveillance server room needs outlet-level control over recording infrastructure. For guidance on sizing PDU capacity against total rack load, see the PoE and power planning guide before finalizing a rack power design. Pair it with rack-mount cable management or a rack mount accessories selection to keep the vertical strip's cord runs organized in a fully populated cabinet. Browse the broader Server Technology catalog for other outlet counts and plug configurations in the same PDU family if this specific outlet mix or 48A rating doesn't match your panel capacity.

What's in the Box

Package contents were not available in verified source evidence for this SKU.

Frequently Asked Questions

Q: What input voltage and plug does the C2WG48TE-DQME2M99 require?

A: It requires a 208V Delta 60A IEC 60309 3P+G 9Hr input circuit, rated for 48A input current and 17.3 kW capacity.

Q: How many outlets does the C2WG48TE-DQME2M99 have?

A: 48 total outlets: 30x C13 (rated up to 12A @ 208V L-L) and 18x configurable high-current outlets (rated up to 16A @ 208V L-L).

Q: Can outlets be switched individually?

A: Yes, this is a switched PDU with outlet-level control, managed over Gigabit Ethernet via HTTP/HTTPS, SSHv2, SNMPv2c/v3, and related protocols.

Q: What's the warranty on the C2WG48TE-DQME2M99?

A: It carries a 2-year limited manufacturer warranty.

Q: What's the operating temperature range for this PDU?

A: 0°C to 60°C with 8%RH to 90%RH humidity, suitable for non-climate-controlled equipment rooms.

Q: What are the physical dimensions of the C2WG48TE-DQME2M99?

A: 80 inches tall by 2.2 inches wide by 2.5 inches deep — a zero-U vertical rack strip.

Karl Wilson
Karl Wilson

I spec a lot of vertical PDUs for camera and recording server racks, and the C2WG48TE-DQME2M99 stands out for its outlet density — 48 total positions in a strip that's only 2.2 inches wide means you're not fighting for rack width in a crowded cabinet. It's built for a 208V 3-phase Delta feed at 48A, which tells you it belongs in a facility with real 3-phase infrastructure, not a single-phase closet.

Technical Highlights:

  • 17.3 kW input capacity: On a 48A/208V Delta circuit, that's enough to run a densely populated rack of NVRs, switches, and servers with headroom before you're anywhere near breaker limits.
  • 30x C13 + 18x configurable Cx outlets: The C13 outlets (<=12A @208V L-L) cover standard IT gear power cords, while the 18 configurable outlets (<=16A @208V L-L) give you flexibility for higher-draw devices without redesigning the whole outlet layout.
  • 10 kAIC branch breaker interrupt rating: Each branch circuit is individually protected, so a short on one outlet group trips only that branch's breaker instead of dropping every device on the strip.

Deployment Considerations:

  • At 80 inches tall, this is a full-height vertical PDU — confirm your rack's usable rail height before ordering, since it's designed to run nearly the full length of a standard 42U-class enclosure.
  • The 208V 3-phase Delta 60A IEC 60309 input plug is not a standard NEMA receptacle — coordinate with your electrician on the panel and receptacle before the unit arrives, since this isn't a plug-and-play single-phase PDU.

This is the right call for a data center or NOC rack running mixed C13 and high-current IT loads off shared 3-phase power, where outlet-level remote switching on a hung device beats a truck roll to the equipment room.

Specifications
Input Voltage: 208V
Frequency: 50/60 Hz
Input Plug: 208V Delta 60A IEC 60309 3P+G 9Hr
Input Current Rated: 48A
Input Power Capacity: 17.3 kW
Outlet Count C13: 30
Outlet Rating C13:
Outlet Count Cx: 18
Outlet Rating Cx:
Branch Circuit Breaker Rating:
Branch Circuit Interrupt Rating: 10 kAIC
Dimensions: 80.0in tall x 2.2in wide x 2.5in deep
Operating Temperature: 0°C to 60°C
Operating Humidity: 8%RH to 90%RH
Storage Temperature: -30°C to 80°C
Storage Humidity: 8%RH to 90%RH
Quiescent Power Draw: < 10W
Ethernet Speed: 10/100/1000 Mbps
Communication Protocols: HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP
North American Safety Standards: UL 62368-1, CSA C22.2 No. 62368-1
North American EMC Standards: FCC Part 15 Class A, CAN ICES-003 Class A
Input Measurement Accuracy Voltage: +/- 1%
Input Measurement Accuracy Current: +/- 1%
Output Measurement Accuracy Voltage: +/- 1%
Output Measurement Accuracy Current: +/- 1%
Branch Measurement Accuracy Current: +/- 3%
Warranty: 2-year limited
Brand: Server Technology
MPN: C2WG48TE-DQME2M99
Type: Network Switch
Connectivity: Ethernet
Power: 10W
Q&A
Reviews

Server Technology Switched Pops Master PRO2 - C2WG48TE-DQME2M99

$5,048.00
$4,816.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources