Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology SEV-FB636B-532P6 Switched 0U Rack PDU

Overview

The Server Technology SEV-FB636B-532P6 is a 3-phase switched Power Distribution Unit (POPS Expansion Pro2 series) built for data center racks that need per-outlet control across a high outlet count without giving up rack unit space. It runs on 400/415V AC 3-phase input through an IEC 60309 input connector and delivers a rated 22.1kW total capacity at 32A input current — enough headroom for a fully populated rack of switching, compute, or storage gear. With 36 total outlets (24x IEC C13 and 12x IEC C19) arranged as alternate-phase HDOT outlets, the SEV-FB636B-532P6 is built to balance load evenly across phases while giving installers a mix of standard and high-current receptacle types on one strip.

Key Features

  • 36-Outlet Mixed Configuration (24x C13 + 12x C19): covers both standard IEC C13-terminated server power cords and higher-draw C19 equipment (blade chassis, larger switches) from a single unit — fewer PDUs to mount and cable per rack.
  • Alternate Phase HDOT Outlets: outlets are sequenced across phases down the strip, which helps installers distribute load evenly during cabling instead of manually tracking phase balance outlet by outlet.
  • 22.1kW Total Power Capacity at 32A Input: sized for dense racks running multiple servers or network chassis simultaneously without derating concerns at typical data center load levels.
  • 400/415V AC 3-Phase Input: matches the 3-phase distribution common in enterprise and colocation data centers, pulling more usable power per circuit than a single-phase feed of the same amperage.
  • 208V AC Output: steps the 3-phase input down to a standard 208V output rail compatible with typical rack-mount server and network equipment power supplies.
  • 0U Rackmount Form Factor: mounts vertically along the rear rack posts and consumes zero rack unit space, leaving the full rack height available for compute, storage, or network gear instead of PDU real estate.
  • Switched Outlet Control: being a Switched PDU (not Basic), the SEV-FB636B-532P6 supports remote outlet-level power cycling — useful for remotely rebooting a hung server or network appliance without a site visit.
  • 13.1ft Cord Length: long enough to route from a variety of overhead or underfloor power whip positions back to the rack without requiring an extension.
  • 50/60 Hz Frequency Support: compatible with both North American 60Hz and international 50Hz electrical infrastructure, which matters for multi-region data center standardization.
  • IEC 60320 Receptacle Standard: uses the globally recognized IEC 60320 receptacle family, so replacement power cords are widely available rather than proprietary.

Integration & Compatibility

At 69 inches tall, 2.2 inches wide, and 2.25 inches deep, the SEV-FB636B-532P6 is sized to run the full height of a standard rack while occupying minimal lateral space, leaving cable management channels and airflow largely undisturbed. The mixed C13/C19 outlet layout means it can serve a rack running a combination of 1U/2U servers (typically C13-terminated) alongside larger switches or blade enclosures (typically C19-terminated) without needing a second PDU or adapter cords. For facilities standardizing on power distribution units across multiple racks, the alternate-phase HDOT layout on this Server Technology PDU lineup simplifies phase-balance planning during initial cabling and later equipment swaps. If you're mapping out rack power budgets across a row, it's worth reviewing a power and PoE planning guide before finalizing PDU counts and circuit assignments, and pairing this PDU with an appropriately rated rack-mount UPS or NVR enclosure where uptime requirements call for battery backup upstream. SEV-FB636B-532P6 (often searched as SEV FB636B 532P6) is part of the PRO2 Switched POPS product series, positioned for environments that need outlet-level switching rather than passive Basic-PDU distribution — check a storage and retention planning guide if you're sizing power alongside recorder storage in the same rack build.

Frequently Asked Questions

Q: What is the total power capacity of the SEV-FB636B-532P6?

A: It's rated for 22.1kW total power capacity at 32A input current, running on 400/415V AC 3-phase power.

Q: How many outlets does the SEV-FB636B-532P6 have?

A: 36 total outlets: 24x IEC C13 and 12x IEC C19, arranged in an alternate-phase HDOT configuration.

Q: Does the SEV-FB636B-532P6 take up rack space?

A: No — it's a 0U rackmount unit that mounts vertically along the rack posts, so it doesn't consume any horizontal rack unit space.

Q: Is the SEV-FB636B-532P6 a switched or basic PDU?

A: It's part of the Switched POPS Pro2 series, meaning it supports outlet-level switching rather than passive always-on distribution.

Q: What input connector does the SEV-FB636B-532P6 use?

A: It uses an IEC 60309 input connector with a 13.1ft cord length.

Q: What output voltage does the SEV-FB636B-532P6 deliver?

A: 208V AC output, stepped down from the 400/415V AC 3-phase input.

James Everett
James Everett

The outlet mix on the SEV-FB636B-532P6 is what stands out to me — 24x C13 plus 12x C19 on one strip means I'm not stocking two separate PDU part numbers for a rack that has both 1U servers and a couple of C19-terminated blade chassis in it.

Technical Highlights:

  • 22.1kW at 32A, 400/415V 3-phase: that input rating gives you real headroom for a densely populated 42U rack without tripping breakers during peak boot-up inrush.
  • Alternate Phase HDOT layout: outlets are sequenced across phases as you go down the strip, so cabling in order naturally keeps the three phases close to balanced instead of leaving it to guesswork.
  • 0U form factor at 69in tall, 2.2in wide: it rides the rear rack posts vertically and doesn't eat into your usable 42U or 48U of equipment space, which matters when every U is already spoken for.

Deployment Considerations:

  • This is a 400/415V 3-phase input unit — confirm your facility's power infrastructure actually delivers 3-phase at that voltage before specifying it; it's not a drop-in swap for a single-phase 208V PDU.
  • The 13.1ft cord length is generous for most whip routing but measure your overhead or underfloor power drop distance first on rows with unusual whip placement.

This is the PDU I'd spec for a colocation or enterprise data center row standardizing on 3-phase power with mixed C13/C19 server and switch gear, where outlet-level remote power cycling on a dead rack unit beats a truck roll at 2am.

Specifications
Product Series: PRO2 Switched POPS
Phase: 3-phase
Input Connectors: IEC 60309
Output Connectors: 24 x IEC C13, 12 x IEC C19
Receptacle Type: IEC 60320
Total Power Capacity: 22.1kW
Input Current: 32A
Total Outlets: 36-Outlets
Cord Length: 13.1ft
Frequency: 50/60 Hz
Input Voltage: 400/415 V AC
Rack Height: 0U
Output Voltage: 208 V AC
Form Factor: 0U Rackmount
Height: 69"
Width: 2.2"
Depth: 2.25"
Brand: Server Technology
MPN: SEV-FB636B-532P6
Type: Power Supply
Connectivity: PoE
Power: 415V AC
Q&A
Reviews

Server Technology Switched Pops Expansion - SEV-FB636B-532P6

$3,603.00
$3,437.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources