Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology C2W54CE-5CAE2M00 Switched 54-Outlet C13 PDU, 415V 3-Phase Wye

Overview

The Server Technology C2W54CE-5CAE2M00 is a switched, three-phase power distribution unit built into the PRO2 platform, delivering 54 individually addressable IEC 60320 C13 outlets off a 415V 3PH Wye input. It's designed for data center and server room racks where you need outlet-level control over dozens of C13-terminated devices — servers, switches, blade chassis power supplies — without running separate branch circuits for each one. At 80 inches long and only 2.2" wide by 2.5" deep, it's built as a vertical zero-U rack mount, running the full height of a standard cabinet along the rear rail without stealing usable U-space from your servers. The C2W54CE-5CAE2M00 (often searched as C2W54CE 5CAE2M00) pulls its 30A input through a NEMA L22-30 plug/connector, a locking twist-lock interface rated for exactly this class of high-density three-phase load.

Key Features

  • 54x IEC 60320 C13 outlets: High outlet density on a single zero-U strip means fewer PDUs per rack and fewer whips to route — a real factor when you're populating a cabinet with 1U/2U servers that each pull two C13 cords for A/B power redundancy.
  • Switched outlet control: Each outlet can be power-cycled independently, which matters when a hung server or network device needs a remote reboot at 2 a.m. without a truck roll to the data center.
  • Three-phase Wye input at 415V: Three-phase distribution balances load across all three legs from one input point, letting you pull more usable power through a single feed than a comparable single-phase circuit — the standard approach for high-density colo and enterprise rack rows.
  • 30A input current via NEMA L22-30: The locking twist-lock connector prevents accidental disconnects in busy cabinet environments, and 30A at 415V 3-phase gives you meaningful headroom across 54 outlets without tripping on startup inrush from multiple servers powering up together.
  • Configurable alternating-phase outlet mapping: Outlets alternate across phases by design, which simplifies balancing load evenly across all three legs as you populate the rack — you don't have to manually track which outlet sits on which phase.
  • Compact footprint (2.2" W x 2.5" D x 80" L): The narrow profile fits standard vertical PDU mounting channels on the rear rails of most enterprise cabinets, running the full rack height without encroaching on cable management or airflow space.
  • United States country of origin: Domestic manufacturing is a straightforward procurement fact worth confirming when a project has domestic-sourcing requirements written into the spec.

Integration & Compatibility

The C2W54CE-5CAE2M00's C13 receptacles pair directly with standard IEC 60320 C13 power cords already terminating most rackmount servers, switches, and network video recorders — no adapters needed for typical enterprise gear. Because it's a switched PDU, it's built to report and control outlet state, which matters if you're planning a rack around remote power management rather than manually flipping breakers. When you're specifying rack power for a new cabinet buildout, pair this PDU decision with a broader look at power distribution units to confirm you're matching outlet count and phase configuration to your actual server density, and check a PoE and power planning guide if the same rack is also feeding PoE switches with separate power budgets. This unit sits within the broader Server Technology PDU catalog, which spans single-phase and three-phase models at different outlet counts for smaller cabinets or lower-current services. If you're building out a full server room rather than a single rack, it's worth reviewing network video recorders and switch gear power draw together so the 30A input on the C2W54CE-5CAE2M00 isn't oversubscribed once every device is racked and running.

What's in the Box

Evidence for this listing does not specify individual package contents beyond the PDU unit itself.

Frequently Asked Questions

Q: What input voltage and phase configuration does the C2W54CE-5CAE2M00 use?

A: It runs on 415V three-phase Wye input, drawing 30A through a NEMA L22-30 plug/connector.

Q: How many outlets does the C2W54CE-5CAE2M00 have and what type?

A: It provides 54 IEC 60320 C13 outlets.

Q: Is the C2W54CE-5CAE2M00 a switched or basic PDU?

A: It's a switched PDU, meaning individual outlets can be controlled rather than only monitored.

Q: What are the physical dimensions of the C2W54CE-5CAE2M00?

A: It measures 2.2" wide by 2.5" deep by 80" long, built for zero-U vertical rack mounting.

Q: Where is the C2W54CE-5CAE2M00 manufactured?

A: Its country of origin is the United States.

Karl Wilson
Karl Wilson

The first thing that jumps out on the C2W54CE-5CAE2M00 is outlet density — 54 C13 receptacles off a single three-phase input is enough to power a full rack of A/B-redundant 1U servers without stacking multiple PDUs on the same rail.

Technical Highlights:

  • 415V 3PH Wye input at 30A: Three-phase Wye distribution at this current rating gives you real headroom for simultaneous server power-up inrush across 54 outlets — something a single-phase 30A PDU can't match at equivalent outlet count.
  • NEMA L22-30 locking input connector: A twist-lock connector rated for this load class means no accidental unplugs in a crowded cabinet — worth specifying whenever the PDU sits behind a rat's nest of cabling.
  • 80" zero-U form factor at 2.2" x 2.5": That footprint runs the full height of a standard 42U-48U cabinet without consuming rack unit space, which matters when every U in the cabinet is already spoken for by compute.

Deployment Considerations:

  • Because this is a switched unit, plan your rack's remote management strategy around individual-outlet control rather than whole-strip on/off — that's the entire value proposition versus a basic PDU at this outlet count.
  • The NEMA L22-30 input requires matching receptacle infrastructure in the cabinet's power whip — confirm your electrical contractor is running the correct twist-lock receptacle before the PDU arrives on site, not after.

This is the right call for a data center row standardizing on three-phase 415V feeds with high-density C13 server power, particularly where outlet-level remote cycling is part of the operations runbook rather than a nice-to-have.

Specifications
PDU Type: Switched
Phase: Three Phase
Plug Connector Type: NEMA L22-30
Receptacle Type: IEC 60320 C13
Receptacle Detail: 54 x IEC 60320 C13
Input Current: 30 A
Width: 2.2"
Depth: 2.5"
Length: 80"
Country of Origin: United States
Brand: Server Technology
MPN: C2W54CE-5CAE2M00
Type: Network Switch
Connectivity: PoE
Power: PoE
Q&A
Reviews

Server Technology Switched Master PRO2 (54) - C2W54CE-5CAE2M00

$3,587.50
$3,424.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources