Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2X42CE-DQME2M00 Switched 3-Phase Delta Rack PDU
The Server Technology C2X42CE-DQME2M00 is a switched power distribution unit built for data center racks running three-phase Delta power, delivering 42 outlets from a 60A input circuit terminated in an IEC 60309 3P+PE plug. This is the PRO2 platform's configurable outlet architecture — HDOT (High Density Outlet Technology) receptacles packed into a compact 2.2" wide by 2.5" deep housing that mounts vertically in the rack without eating into usable rail space. For facilities managers standardizing on switched, outlet-level control across a three-phase environment, the C2X42CE-DQME2M00 (often searched as C2X42CE DQME2M00) is a straightforward fit for high-density server and network racks.
Overview
This PDU is classed as a Switched unit, meaning each outlet (or outlet group, depending on configuration) can be individually powered on, powered off, or cycled remotely — a meaningful capability when a rack holds gear that occasionally needs a hard power reset and physical access is inconvenient or restricted. Three-phase Delta input on a 60A circuit gives it substantially more distributable capacity than a comparable single-phase unit, which is why this class of PDU shows up in enterprise and colocation racks rather than small server closets. The 42-outlet count on this SKU sits it between the smaller HDOT configurations and the larger 48- and 54-outlet PRO2 variants in the same family, giving it a place for racks with dense but not maximal device counts.
Key Features
- Switched outlet control: individual outlet-level on/off/cycle means a locked-up server or network appliance can be power-cycled without a technician walking to the rack — a real time-saver for remote or lights-out facilities.
- Three-phase Delta input: three-phase power distributes electrical load more evenly than single-phase, letting one PDU chassis support far more connected equipment before tripping a breaker.
- 60A input current: a 60A circuit gives real headroom for dense racks running blade servers, switches, and storage arrays simultaneously rather than forcing load-balancing compromises across multiple smaller PDUs.
- IEC 60309 3P+PE 60A plug/connector: an industrial-grade locking connector rated for the full 60A load, reducing the risk of a loose or arcing connection under sustained high-current draw.
- 42 HDOT outlets: High Density Outlet Technology packs 42 receptacles into a narrow 2.2" profile, so the PDU occupies minimal vertical rail space that would otherwise go to servers or patch panels.
- Compact physical footprint: at 2.2" wide by 2.5" deep, this PDU is built to mount in the narrow side channel of an open rack or cabinet without interfering with cable management or airflow.
- Configurable alternate-phase layout: outlets are arranged to alternate phase assignment down the strip, which simplifies balancing load across all three phases as you populate the rack rather than manually tracking which outlet belongs to which leg.
Integration & Compatibility
The C2X42CE-DQME2M00 is manufactured under the Server Technology brand, part of the Legrand Group, and is built on the PRO2 platform — Server Technology's switched and monitored PDU line. It pairs naturally with three-phase Delta electrical infrastructure already common in enterprise data centers and colocation facilities; confirm your facility's phase configuration matches before ordering, since Server Technology also produces Wye-configured equivalents (such as the C2W42CE-DQME2M00) for sites wired differently. For racks planning outlet-level metering alongside switching, or for teams evaluating power distribution units more broadly, review a PDU selection guide before finalizing phase and outlet-count requirements. This unit is commonly specified alongside rack cabling and cable management accessories to keep the dense outlet strip organized once fully populated. Browse the full Server Technology PDU catalog for adjacent capacities, including 48- and 54-outlet configurations, if 42 outlets doesn't match your rack density.
Frequently Asked Questions
Q: What's the input current on the C2X42CE-DQME2M00?
A: It's rated for 60A input current, terminated in an IEC 60309 3P+PE 60A plug/connector.
Q: Is this a switched or basic PDU?
A: The C2X42CE-DQME2M00 is a Switched PDU, allowing individual outlet-level power control.
Q: How many outlets does the C2X42CE-DQME2M00 have?
A: It has 42 outlets in an HDOT (High Density Outlet Technology) configuration.
Q: What phase configuration does this PDU use?
A: It's a three-phase Delta unit, distinct from Wye-configured variants in the same Server Technology family.
Q: What are the physical dimensions of the C2X42CE-DQME2M00?
A: It measures 2.2" wide by 2.5" deep, sized for vertical mounting in the rack's side channel.

The C2X42CE-DQME2M00 crosses my desk most often when a customer is standardizing rack power across a colo footprint on three-phase Delta service. The spec that matters here is the 60A input on an IEC 60309 3P+PE connector — that's a locking industrial connector, not a standard IEC C20, so confirm your facility's whip and receptacle match before this ships.
Technical Highlights:
- 42 HDOT outlets in a 2.2" x 2.5" footprint: that outlet density in a strip this narrow is the whole reason PRO2 exists — you get 42 switched receptacles without sacrificing a full rack unit of usable space.
- Switched control at 60A three-phase: individually cycling outlets on a unit this size means you're not sending someone to the cage for a hung appliance reboot, which matters more as the outlet count climbs past 40.
- Three-phase Delta input: Delta and Wye are not interchangeable — Server Technology sells both configurations (the C2W42CE-DQME2M00 is the Wye counterpart), so this spec alone determines which SKU is correct for a given facility.
Deployment Considerations:
- Verify your electrical service is Delta, not Wye, before ordering — the two configurations aren't interchangeable, and the wrong one won't terminate safely on your panel.
- At 60A input, this unit needs a properly rated circuit and receptacle upstream; this isn't a plug-and-go 15A strip, and your electrician needs to confirm capacity before installation.
This is the right call for a colocation or enterprise data center rack on three-phase Delta service that needs outlet-level switching across 40+ devices without burning a full rack unit on the PDU itself.
Compare with similar
Server Technology Switched Link PRO2 (42) - C2X42CE-DQME2M00
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology