Vertiv SR2-3XIT Racks 20KW-POWERREDUNDANCY - SR2N03020PAA1
3-rack unit (3U) IT rack designed for high-density power distribution in commercial environments
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv SR2N03010PAA1 is a pre-engineered, three-rack integrated row system rated to 10 kW total capacity — the right starting point for small-to-mid-scale edge deployments, branch data centers, and distributed enterprise compute rows where power redundancy matters but floor space is tightly managed. The system ships as a 2,700 mm row, combining three 42U x 600 x 1400 mm cabinets with an integrated cooling unit, a 10 kW PMC power distribution tier, and six 30A PDUs — everything needed to stand up a structured, power-redundant compute row without field-engineering the individual components together.
Where the non-redundant sibling (SR2N03010NAA1) provides only three PDUs for the same three-rack row, the SR2N03010PAA1 doubles PDU count to six — two per rack — giving each cabinet its own A-feed and B-feed path. That's the core tradeoff you're making when you step up to this SKU: you're paying for the second-feed coverage across all three cabinets, not adding cooling capacity or changing the power distribution tier.
The SR2 integrated row system is designed to slot into Vertiv's broader data center infrastructure ecosystem. The 10 kW PMC distribution tier interfaces with Vertiv power management software for centralized monitoring, though specific VMS or DCIM integration requirements should be confirmed against your site's management platform before ordering. The standard 42U cabinet dimensions are compatible with industry-standard rack-mount equipment across compute, storage, and networking categories. Existing power and UPS infrastructure should be sized to feed the row's 10 kW aggregate draw plus any headroom required by site policy — the PMC tier handles in-row distribution, not upstream supply.
For deployments requiring higher density, Vertiv's SR2 line scales to 20 kW rows in 3-, 4-, and 5-rack configurations. The Vertiv product catalog covers the full SR2 matrix including fire-suppression and full-redundancy variants. If your project involves adjacent structured cabling or physical infrastructure planning, review the rack enclosures category for complementary cabinet accessories and containment components. Teams planning multi-row deployments should also evaluate power distribution options upstream of the PMC tier to ensure feed capacity matches the aggregate row load.
Q: What is the difference between the SR2N03010PAA1 and the SR2N03010NAA1?
A: Both are 10 kW, 3-rack, 2,700 mm rows with one cooling unit and 10 kW PMC distribution. The key difference is PDU count: the NAA1 (non-redundant) includes 3 PDUs (one per rack), while the SR2N03010PAA1 (power-redundant) includes 6 PDUs (two per rack), enabling an A/B feed path to each cabinet.
Q: Does the SR2N03010PAA1 include fire suppression?
A: No. The SR2N03010PAA1 does not include integrated fire suppression. If fire suppression is required, the SR2N03010PAA2 is the equivalent configuration with that feature, though it adds 600 mm to the row length (3,300 mm total).
Q: Is cooling redundant on the SR2N03010PAA1?
A: No. This SKU includes one cooling unit serving the entire 2,700 mm row. Cooling redundancy (N+1) is available on the full-redundancy variant SR2N03010FAA1, which includes two cooling units at a 3,000 mm row length.
Q: What is the per-rack power capacity of the SR2N03010PAA1?
A: The 10 kW total capacity is distributed across three racks, yielding approximately 3.3 kW per rack. This suits moderate-density equipment loads; high-density compute averaging above 4–5 kW per rack should be evaluated against the 20 kW SR2 variants instead.
Q: What PDU type does the SR2N03010PAA1 use?
A: The system includes six 30A PDUs — two per rack — managed through the integrated 10 kW PMC power distribution tier.
Q: Can I expand the SR2N03010PAA1 to additional racks later?
A: The SR2N03010PAA1 is a factory-configured 3-rack integrated row. Expansion to 4- or 5-rack configurations requires a different SKU from the SR2 line (SR2N04020 or SR2N05020 series). Field expansion of integrated row systems is not a supported upgrade path — plan rack count requirements before ordering.

The SR2N03010PAA1 is the power-redundant configuration of Vertiv's three-rack integrated row — the six 30A PDUs are the whole point of this SKU versus the three-PDU NAA1 sibling. If you're specifying this system, you're buying A/B feed capability for each of the three 42U cabinets without field-engineering the redundancy yourself.
Technical Highlights:
Deployment Considerations:
This system is well-matched to edge data rooms and distributed enterprise deployments running mixed compute at moderate density — think branch office server consolidation, security operations infrastructure, or small-scale virtualization clusters where power redundancy at the rack level is specified but thermal loads stay under 3.3 kW per cabinet.