Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FR9TP55A001F012 Opti-Core 12-Fiber Single-Mode ST Interconnect Cable

The Panduit FR9TP55A001F012 is a factory-terminated 12-fiber single-mode interconnect assembly designed for mission-critical data center and telecommunications infrastructure. This 12-foot pre-terminated cable eliminates field termination time and variability, delivering consistent insertion loss performance and immediate deployment capability for backbone fiber runs between equipment racks, telecommunications rooms, and entrance facilities. Built on Panduit's Opti-Core platform with ST connectors and standard interlock (IL) design, this assembly supports high-density fiber distribution in environments where installation speed and long-term reliability are non-negotiable.

Key Features

  • Factory-terminated 12-fiber single-mode assembly eliminates field termination labor and insertion loss variability
  • ST connectors with standard interlock design for secure, repeatable connections in legacy and hybrid fiber installations
  • 12-foot length optimized for intra-rack and short inter-rack backbone runs in data centers and telecom rooms
  • Opti-Core platform construction ensures consistent attenuation and return loss across all 12 fibers
  • Pre-tested and labeled at the factory — immediate deployment with full performance documentation
  • Single-mode fiber supports long-distance transmission and future bandwidth expansion without infrastructure replacement

Pre-terminated fiber assemblies solve the two most expensive problems in structured cabling deployments: installation time and performance unpredictability. Field termination of 12-fiber trunk cables requires specialized fusion splicing equipment, trained technicians, and clean-room conditions that add days to project timelines and introduce insertion loss variability between 0.3 dB and 1.2 dB depending on technician skill and environmental conditions. The FR9TP55A001F012 arrives factory-terminated and factory-tested with guaranteed insertion loss specifications, allowing integrators to pull cable, seat connectors, and verify link performance in under 30 minutes per run. In large-scale data center builds where hundreds of fiber links are deployed simultaneously, this time savings translates to reduced labor costs and faster time-to-production for critical network infrastructure.

The 12-fiber count and ST connector type position this assembly for telecommunications and enterprise data center environments that standardized on ST infrastructure in the 1990s and 2000s and now require high-density backbone upgrades without forklift replacements of patch panels and cross-connect hardware. ST's bayonet coupling mechanism provides tactile feedback and mechanical strength that survives decades of connect-disconnect cycles in 24/7 production environments. The standard interlock design ensures compatibility with legacy Panduit and third-party ST adapters, eliminating the adapter replacement costs and downtime associated with proprietary keying systems. Single-mode fiber delivers the bandwidth headroom to support 10G, 40G, and 100G Ethernet upgrades on the same physical infrastructure, protecting capital investment as network speeds increase.

Panduit's Opti-Core platform is a factory quality control system that subjects every fiber in every cable to automated insertion loss and return loss testing before the assembly ships. Each cable includes a serialized test report documenting performance per fiber pair, giving integrators the audit trail required for TIA-568 acceptance testing and warranty claims. The 12-foot length is the sweet spot for equipment distribution area (EDA) backbone runs — long enough to route from floor-mounted racks to overhead cable tray and across to adjacent rows, short enough to avoid the attenuation penalties and handling complexity of 50-foot or 100-foot trunk assemblies. This assembly is the workhorse link for connecting switch aggregation layers to storage arrays, SAN fabrics, and telecom carrier demarcation points in facilities where fiber infrastructure uptime is measured in five-nines.

Specifications
Product Type: Fiber Optic Cable Assembly
Fiber Count: 12
Fiber Type: Single-Mode
Connector Type: ST
Connector Design: Standard Interlock (IL)
Overall Length: 12 ft (3.7 m)
Sub-Brand: Opti-Core®
Application: Data centers, telecommunications rooms, entrance facilities, equipment distribution areas
Termination: Factory Pre-Terminated
Testing: Factory tested with serialized performance documentation
Insertion Loss: Per factory test report (typical
Standards Compliance: TIA-568
Deployment Type: Backbone, interconnect, equipment distribution
Type: Cable
Connectivity: Fiber Optic
Cable Category: other
Application: Data centers, telecommunications rooms, entrance facilities, and equipment distribution areas requiring pre-terminated fiber infrastructure for rapid deployment.
Connector Type: ST
Length Ft: 12.0
Length M: 3.7
Sub Brand: Opti-Core®
Q&A
Reviews
Have Questions?

Panduit FR9TP55A001F012 12-Fiber ST Cable 12 ft

$595.26
$385.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources