Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C1S15HN-YQJN5BC3-013 Smart Rack PDU with PIPS
Overview
The Server Technology C1S15HN-YQJN5BC3-013 is a PRO1 Smart PDU rated for 14.4kW-17.3kW, built for rack and cabinet power distribution in data center and colocation environments. It terminates on a 208V Wye 60A IEC 60309 3P+N+G plug and delivers 17.3kW of input power capacity across a 15-outlet output configuration — 3x IEC 60320/C13 and 12x IEC 60320/C19. If you're standardizing on a single-PDU-per-rack model for mixed server and network gear, the C1S15HN-YQJN5BC3-013 covers both C13 and C19 device cords without adapters. This is a horizontal-mount unit measuring 3.5in x 17.2in x 10.1in, sized for standard rack rail mounting.
Key Features
- Per-Inlet Power Sensing (PIPS): billing-grade measurement of current, voltage, active power, apparent power, power factor, crest factor, and energy at the inlet — accuracy is +/- 1% for current, voltage, power, and apparent power, +/- 3% for power factor. That level of accuracy matters if you're doing cost allocation or capacity billing back to tenants or internal departments.
- Auto-Flip Current Display: local LEDs show current per phase directly on the unit, so techs racking equipment can read safe loading margins without opening a browser tab — useful during live installs when you're balancing load across phases by hand.
- Branch Circuit Protection: six 2-pole, UL489-compliant 20A trip breakers rated <= 16A each with 10 kAIC interrupt rating. A tripped breaker on one branch takes down only that branch's outlets, not the whole PDU — contains a downstream short to a handful of C13/C19 ports instead of the full rack.
- Hot-Swap Network Card: network access continues even if the primary unit loses power, since backup power comes from a linked unit — relevant in multi-linked deployments where remote monitoring can't go dark during a power event.
- Temperature/Humidity Monitoring: two 4P4C inputs accept external probes for SNMP-based alerts and email notifications — lets you tie rack-level environmental data into existing monitoring without a separate sensor platform.
- High Retention Locking Outlets: compatible with P-Lock type power cords, which reduces the risk of a cord working loose from vibration or accidental tension in a densely cabled rack.
- Gigabit Ethernet Management: 10/100/1000 Mbps interface plus RS-232 serial, so the PDU can sit on a dedicated out-of-band management network without bottlenecking on a 100Mbps port shared with other devices.
- Broad Protocol Support: HTTP(S), SSH, Telnet, SNMPv2c/v3, (S)FTP, SMTP, Syslog, LDAP(S), TACACS+, and RADIUS are all supported — this covers most enterprise NOC toolchains without requiring a proprietary agent.
Integration & Compatibility
The web interface runs over HTTP/HTTPS with TLSv1.2, and the CLI supports SSHv2, Telnet, SNMPv2c/v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, and RADIUS/FTP-SFTP — this gives network and security teams a consistent authentication path (TACACS+/RADIUS) instead of managing local PDU credentials separately. The RJ-12 link port supports Star Multi-Linking, tying multiple power circuits under one IP address for simplified management in high-density cabinets. Operating range is rated 0°C to 50°C and 8%RH to 90%RH non-condensing at up to 6,500ft elevation, with storage tolerance down to -40°C. Certifications include UL 62368-1, CSA C22.2 No. 62368-1, FCC Part 15 Class A, and CAN ICES-003 Class A — the Class A FCC/ICES rating confirms this unit is intended for commercial and industrial environments, not residential installs. The C1S15HN-YQJN5BC3-013 (often searched as C1S15HN YQJN5BC3 013) fits environments already standardized on Server Technology's Server Technology PDU catalog for cross-rack consistency in firmware and monitoring. For broader rack power planning across a row, review a power planning guide before finalizing PDU counts per cabinet. Pair this PDU with compatible rack-mount network recorders or switching gear where C13/C19 outlet mix needs to match device cord types, and consult the rack PDU category for higher- or lower-capacity variants if 17.3kW doesn't match your circuit sizing.
Frequently Asked Questions
Q: What input plug does the C1S15HN-YQJN5BC3-013 use?
A: It terminates on a 208V Wye 60A IEC 60309 3P+N+G plug rated for 9-hour continuous duty, with input current rated at 48A against a 60A plug rating.
Q: How many outlets does the C1S15HN-YQJN5BC3-013 have?
A: It provides 15 total outlets — 3x IEC 60320/C13 rated <= 12A @ 208V L-L (15A peak) and 12x IEC 60320/C19 rated <= 16A @ 208V L-L (20A peak).
Q: Does the C1S15HN-YQJN5BC3-013 support per-outlet or per-inlet monitoring?
A: It uses PIPS (Per-Inlet Power Sensing) technology, monitoring current, voltage, power, apparent power, crest factor, power factor, and energy at the inlet level with +/- 1% accuracy on current, voltage, and power.
Q: What network protocols does this PDU support?
A: HTTP(S), SSH, Telnet, SNMP (v2c and v3), (S)FTP, SMTP, Syslog, LDAP(S), RS-232, TACACS+, and RADIUS.
Q: What is the operating temperature range?
A: 0°C to 50°C with 8%RH to 90%RH non-condensing humidity, rated to 6,500ft/2km elevation.
Q: What certifications does the C1S15HN-YQJN5BC3-013 carry?
A: UL 62368-1, CSA C22.2 No. 62368-1, FCC Part 15 Class A, and CAN ICES-003 Class A.

What stands out on the C1S15HN-YQJN5BC3-013 is the inlet-level metering — PIPS gives you billing-grade accuracy (+/- 1% on current, voltage, and power) at a single measurement point rather than per-outlet, which keeps the unit simpler to troubleshoot when you're staring at a breaker trip at 2am. With 17.3kW of input capacity behind a 208V Wye 60A plug, this is sized for a densely populated rack, not a half-empty cabinet.
Technical Highlights:
- 15-outlet mix (3x C13, 12x C19): the C19-heavy layout tells you this unit is built for higher-draw devices — servers and switches pulling more than a typical desktop PSU — while still keeping three C13s available for lighter loads like KVM or management appliances.
- Six-branch UL489 protection at 10 kAIC: each branch trips independently at <= 16A, so a dead short on one C19 outlet doesn't take the rest of the rack down with it. Worth knowing when you're planning which devices share a branch.
- Gigabit management port: the 10/100/1000 Mbps Ethernet interface avoids the throughput bottleneck you'd get on a 10/100-only PDU if you're polling SNMP data across a large multi-PDU deployment.
Deployment Considerations:
- The 60A input current rating against a 48A rated current means there's headroom built into the plug spec — size your upstream breaker and panel accordingly, not just to the 48A continuous figure.
- Elevation is capped at 6,500ft/2km operating — a detail that matters for high-altitude data center or edge sites and is easy to overlook when specing standard PDUs for a mountain-region facility.
This is the right PDU for a single high-density rack running a mix of servers and network switches on 208V three-phase power, where you need inlet-level billing data and want branch-level fault isolation instead of one large breaker for the whole unit.
Compare with similar
Server Technology Smart PRO1 With Pips - C1S15HN-YQJN5BC3-013
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology