Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology C2SG36CE-DCMFAM00 Switched Rack PDU

The Server Technology C2SG36CE-DCMFAM00 is a vertical zero-U switched power distribution unit built for data center racks that need granular outlet control and real-time power monitoring rather than a dumb strip. It runs on a 208V input at 30A (24A rated) through a NEMA L15-30P plug, delivering an 8.6kW input power capacity across 36 IEC 60320/C13 outlets. If you're standardizing on switched, monitored PDUs for a colocation row or an enterprise server room, the C2SG36CE-DCMFAM00 gives you outlet-level visibility without adding a separate monitoring appliance.

Overview

This is a vertical mount unit at 70 inches tall, 2.2 inches wide, and 2.5 inches deep — sized to run the full height of a standard rack without stealing usable U-space from servers or switches. Each C13 outlet is rated up to 12A at 208V line-to-line (15A peak), and outlets are protected downstream of a 2-pole 20A branch circuit breaker with a 10 kAIC interrupt rating, so a shorted device trips its branch instead of taking down the whole PDU or the upstream panel.

Key Features

  • 8.6kW Input Power Capacity at 208V/30A: Sized for dense server and network racks where a single 15A or 20A strip won't cover the load — the C2SG36CE-DCMFAM00 gives headroom for blade chassis and multi-PSU servers on one circuit.
  • 36x IEC 60320/C13 Outlets: Enough outlet count to power a fully loaded rack from one vertical unit, avoiding daisy-chained strips that create cable clutter and single points of failure.
  • Per-Outlet Rating of ≤12A @ 208V L-L (15A Peak): Each outlet is individually rated, not just the whole strip — useful when planning load balance across a rack of mixed-draw equipment.
  • 2-Pole 20A Branch Breaker, 10 kAIC Interrupt Rating: A faulted device trips its own branch circuit rather than the whole PDU, which keeps one bad power supply from taking a rack offline.
  • Gigabit Ethernet (10/100/1000 Mbps, RJ-45) Management: Full-speed network management for remote monitoring and control — no bottleneck when pulling metering data or pushing firmware over the management port.
  • RS-232 Serial (RJ-45) and RJ-12 Link Port: Local console access for initial configuration plus a link port for daisy-chaining multiple PDU management sessions through a single network drop — cuts down on how many IP addresses you burn in the rack.
  • Broad Network Protocol Support (HTTPS/TLSv1.2, SSHv2, SNMPv2c/v3, LDAPv3/LDAPS, TACACS+, RADIUS, SFTP): Covers encrypted management and centralized authentication (LDAP, TACACS+, RADIUS) so the PDU can plug into existing enterprise AAA infrastructure instead of running local-only accounts.
  • Two 4P4C Temperature/Humidity Sensor Ports: Lets you tie ambient rack conditions into the same monitoring feed as outlet-level power data — one pane of glass for environmental and electrical health.
  • Quiescent Unloaded Power Draw Under 10W: The PDU's own overhead is negligible against an 8.6kW capacity — it isn't eating a meaningful chunk of your circuit budget just to run its management electronics.
  • Output Current Measurement Accuracy of ±1% at 0.01A: Precise enough for real per-outlet billing or capacity-planning data, not just a rough load indicator.
  • Operating Range of 0°C to 60°C, 8-90% RH Non-Condensing: Rated for hot-aisle containment environments up to 140°F, so placement near exhaust airflow isn't a problem.
  • UL 62368-1 / CSA C22.2 No. 62368-1 Safety Listing: Certified to the current audio/video/IT safety standard, relevant for data center electrical inspections and insurance documentation.

Integration & Compatibility

The C2SG36CE-DCMFAM00 (often searched as C2SG36CE DCMFAM00) supports IPv4/IPv6 and integrates into existing network monitoring stacks via SNMPv2c/v3, making it compatible with most enterprise DCIM and NMS platforms that poll standard MIBs. Pair it with rack-mounted network video recorders or switching gear in the same cabinet, and reference a PoE planning guide when sizing total rack power budgets across IT and security loads sharing the same circuits. For full rack builds, browse the broader Server Technology catalog alongside network switches and rack mounting accessories to complete the cabinet.

Frequently Asked Questions

Q: What is the input voltage and plug type for the C2SG36CE-DCMFAM00?

A: It runs on 208V, 30A input (24A rated) through a NEMA L15-30P plug at 50/60 Hz.

Q: How many outlets does the C2SG36CE-DCMFAM00 have?

A: 36 IEC 60320/C13 outlets, each rated up to 12A at 208V line-to-line (15A peak).

Q: What is the total power capacity of this PDU?

A: 8.6kW input power capacity.

Q: Can the C2SG36CE-DCMFAM00 be managed remotely over the network?

A: Yes. It has a 10/100/1000 Mbps Gigabit Ethernet RJ-45 port and supports HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, LDAPv3/LDAPS, TACACS+, RADIUS, and FTP/SFTP for remote management and authentication.

Q: What are the physical dimensions of the C2SG36CE-DCMFAM00?

A: 70.0 inches tall, 2.2 inches wide, and 2.5 inches deep — a vertical zero-U form factor.

Q: Does the C2SG36CE-DCMFAM00 support environmental sensors?

A: Yes, it includes two 4P4C ports for temperature and humidity sensors.

Jerry Tildsen
Jerry Tildsen

The C2SG36CE-DCMFAM00 is one of the higher-density vertical PDUs I spec for rack builds that need 36 outlets on a single 208V/30A drop — an 8.6kW input capacity puts it solidly in server-room and colo territory rather than a light office rack.

Technical Highlights:

  • 2-pole 20A branch breaker, 10 kAIC: That interrupt rating matters in a shared-panel environment — a downstream fault clears without stressing upstream protection.
  • Output current accuracy of ±1% at 0.01A: Tight enough for real chargeback or capacity-planning numbers, not a rough estimate.
  • Quiescent draw under 10W: Against an 8.6kW budget, the unit's own overhead is a rounding error.

Deployment Considerations:

  • The 70-inch vertical form factor needs a rack with clear zero-U rail space on the side — measure before ordering if you're retrofitting an occupied cabinet.
  • Each C13 outlet tops out at 12A continuous (15A peak) — don't plan to run high-draw C14 devices near that ceiling on a single outlet without checking total branch load against the 20A breaker.

I'd put the C2SG36CE-DCMFAM00 in a colocation or enterprise data center row where you're standardizing on switched, monitored power and want environmental sensor ports on the same management interface as outlet metering — not in a light-load network closet where a simpler unswitched strip would do the job for less.

Specifications
Input Voltage: 208V
Frequency: 50/60 Hz
Input Plug: NEMA L15-30P
Input Current: 30A
Input Current Rated: 24A
Input Power Capacity: 8.6kW
Outlet Connector Rating: IEC 60320/C13
North American Outlet Rating: ≤ 12A @208V L-L (15A Peak)
Branch Circuit Breaker Rating: 2-pole, 20A
Branch Circuit Interrupt Rating: 10 kAIC
Dimensions: 70.0in tall x 2.2in wide x 2.5in deep
Operating Temperature: 32°F to 140°F / 0°C to 60°C
Operating Humidity: 8%RH to 90%RH non-condensing
Operating Elevation: 6,500ft/2km
Storage Temperature: -22°F to 176°F / -30°C to 80°C
Storage Humidity: 8%RH to 90%RH non-condensing
Storage Elevation: 50,000ft/15km
Quiescent Unloaded Power Draw: < 10W
Ethernet Speed: 10/100/1000 Mbps
Ethernet Connector: RJ-45
Serial Interface: RS-232
Serial Connector: RJ-45
Temperature Humidity Sensor Ports: Two (2) 4P4C
Link Port: RJ-12
Network Protocols: HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP
Safety Certification: UL 62368-1, CSA C22.2 No. 62368-1
EMC Certification: FCC Part 15 Subpart B Class A, CAN ICES-003 Class A
Input Current Measurement Accuracy: ± 10% at 0.1 amp (0.3 - 9.9 amps)
Output Current Measurement Accuracy: ± 1% at 0.01 amp
Branch Current Measurement Accuracy: ± 3% at 0.01 amp
High Temperature Rating: 60 °C
Brand: Server Technology
MPN: C2SG36CE-DCMFAM00
Q&A
Reviews

Server Technology Smart Pops Master PRO2 - C2SG36CE-DCMFAM00

$3,423.00
$3,310.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources