Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C1S24SP2CAA4A6/C 2U Rack-Mount Basic PDU
The Server Technology C1S24SP2CAA4A6/C is a 2U rack-mount power distribution unit built for data center and server room cabinets that need a high outlet count in a compact footprint. It's rated 208V at 30A, fed through a NEMA L6-30P twist-lock input plug, and splits that capacity across 18 C13 outlets plus 6 combination C13/C19 (CX) outlets — 24 total outlets from a single 2U rack space. At 18 lbs, it mounts into standard 19-inch racks without eating significant weight budget or requiring reinforced rail hardware.
Overview
This is a basic (non-metered, non-switched) PDU in Server Technology's Smart line, sold under mfg. part number C1S24SP-2CAA4A6/C. It's positioned for server, network, and storage racks where the priority is outlet density and reliable 208V distribution rather than remote monitoring or per-outlet switching. The C1S24SP2CAA4A6/C is a straightforward answer to a common rack-build problem: too many devices, not enough outlets, and not enough rack units to spare on power hardware.
Key Features
- 24 total outlets (18x C13 + 6x CX): the 18 standard C13 outlets handle servers, switches, and network appliances with standard IEC power cords, while the 6 combination C13/C19 (CX) outlets accept either connector type — useful when a handful of devices in the rack pull higher current and ship with C19 cords instead of C13.
- 2U form factor: outlet-dense PDUs at this count often run 2U or larger; keeping it to 2U instead of 3U leaves more usable rack space for compute and storage in a standard 42U cabinet.
- 208V / 30A rated circuit: matches standard commercial data center branch circuits, so it drops into existing 208V/30A whip or receptacle infrastructure without a transformer or step-down.
- NEMA L6-30P twist-lock input: a locking plug reduces the risk of accidental disconnection in a busy rack row compared to a straight-blade plug — important on a PDU feeding 24 downstream devices.
- 18 lbs unit weight: light enough for a single technician to rack and secure without a lift, which matters when you're doing a multi-PDU build-out across several cabinets in one day.
Integration & Compatibility
The C1S24SP2CAA4A6/C is a passive distribution unit — it delivers 208V/30A service to whatever IEC-corded equipment sits in the rack, from servers and switches to network video recorders and other rack-mount appliances. Because it draws on a 208V/30A circuit rather than standard 120V, confirm your facility's rack power whip matches before ordering; mismatched voltage plans are one of the most common PDU return reasons in data center builds. For guidance on matching outlet count and circuit capacity to a planned cabinet load, see this site's PoE and power planning guide.
What's in the Box
Ships as a single C1S24SP2CAA4A6/C PDU unit. No accessory kit contents are listed in available documentation for this SKU.
Frequently Asked Questions
Q: How many outlets does the C1S24SP2CAA4A6/C have?
A: 24 total — 18x C13 outlets plus 6x combination C13/C19 (CX) outlets.
Q: What input plug does the C1S24SP2CAA4A6/C use?
A: A NEMA L6-30P twist-lock plug rated for 208V at 30A.
Q: How much rack space does the C1S24SP2CAA4A6/C take up?
A: It's a 2U rack-mount unit.
Q: How much does the C1S24SP2CAA4A6/C weigh?
A: 18 lbs.
Q: Is the C1S24SP2CAA4A6/C a switched or metered PDU?
A: Available documentation for this SKU does not indicate switching or metering features — treat it as a basic distribution unit unless confirmed otherwise at time of quote.

The outlet count is what stands out on the C1S24SP2CAA4A6/C — 24 total receptacles in 2U is a lot of density, and it's why this unit shows up in racks where you're consolidating power for a full shelf of 1U servers or switches instead of running two separate PDUs.
Technical Highlights:
- 18x C13 + 6x C13/C19 combo outlets: the combo (CX) outlets give you flexibility for the handful of devices in most racks that ship with a C19 cord instead of C13, without needing a separate high-current PDU.
- 208V/30A via NEMA L6-30P: a twist-lock input this size is standard for data center branch circuits — no adapters, no step-down, just confirm the whip matches before you order.
- 2U / 18 lbs: dense outlet count without eating 3+ rack units, and light enough to rack solo during a build-out.
Deployment Considerations:
- This is a basic distribution unit — plan your monitoring and remote-switching strategy separately if the rack requires it, since nothing in the available spec sheet confirms metering or outlet-level switching on this model.
- Verify your facility circuit is actually 208V/30A with an L6-30R receptacle before install; a 30A twist-lock PDU won't drop into a 120V or straight-blade circuit.
Reach for the C1S24SP2CAA4A6/C when you're standing up a dense server or network cabinet on a 208V/30A circuit and need more outlets than a standard 8-12 port PDU offers, without giving up more than 2U of rack space to do it.
Compare with similar
Server Technology Smart 2U 18XC13+6XCX - C1S24SP2CAA4A6/C
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology